Microdosimetric measurements in the thermal neutron irradiation facility of LENA reactor.

A twin TEPC with electric-field guard tubes has been constructed to be used to characterize the BNCT field of the irradiation facility of LENA reactor. One of the two mini TEPC was doped with 50ppm of (10)B in order to simulate the BNC events occurring in BNCT. By properly processing the two microdosimetric spectra, the gamma, neutron and BNC spectral components can be derived with good precision (~6%). However, direct measurements of (10)B in some doped plastic samples, which were used for constructing the cathode walls, point out the scarce accuracy of the nominal (10)B concentration value. The influence of the Boral(®) door, which closes the irradiation channel, has been measured. The gamma dose increases significantly (+51%) when the Boral(®) door is closed. The crypt-cell-regeneration weighting function has been used to measure the quality, namely the RBEµ value, of the radiation field in different conditions. The measured RBEµ values are only partially consistent with the RBE values of other BNCT facilities.

[1]  J. Herault,et al.  Microdosimetric measurements in the fast neutron therapeutic beam of Nice , 1998 .

[2]  J. Burmeister,et al.  Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry. , 2001, Medical physics.

[3]  M. Soncin,et al.  Feasibility of BNCT Radiobiological Experiments at the HYTHOR Facility , 2008 .

[4]  J. Capala,et al.  An international dosimetry exchange for boron neutron capture therapy, Part I: Absorbed dose measurements. , 2005, Medical Physics (Lancaster).

[5]  H. Amols,et al.  Microdosimetry for boron neutron capture therapy. , 1992, Radiation research.

[6]  A. Mazal,et al.  Radiobiological Effectiveness of Radiation Beams With Broad Let Spectra - Microdosimetric Analysis Using Biological Weighting Functions , 1994 .

[7]  J. Burmeister,et al.  Microdosimetric intercomparison of BNCT beams at BNL and MIT. , 2003, Medical physics.

[8]  S. Altieri,et al.  Thermal neutron irradiation field design for boron neutron capture therapy of human explanted liver. , 2007, Medical physics.

[9]  J. Herault,et al.  Microdosimetric Assessment of Nice Therapeutic Proton Beam Biological Quality , 2004 .

[10]  J. Fowler,et al.  Neutron dosimetry for biology and medicine , 1978 .

[11]  V. Grégoire,et al.  Intestinal crypt regeneration in mice: a biological system for quality assurance in non-conventional radiation therapy. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  A. Tilikidis,et al.  An estimation of the relative biological effectiveness of 50 MV bremsstrahlung beams by microdosimetric techniques. , 1996, Physics in medicine and biology.

[13]  G Magrin,et al.  Mini-TEPCs for radiation therapy. , 2004, Radiation protection dosimetry.

[14]  H. Arlinghaus,et al.  Boron analysis and boron imaging in biological materials for Boron Neutron Capture Therapy (BNCT). , 2008, Critical reviews in oncology/hematology.

[15]  D Moro,et al.  BNCT dosimetry performed with a mini twin tissue-equivalent proportional counters (TEPC). , 2009, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[16]  A. Wambersie Contribution of Microdosimetry to the Specification of Neutron Beam Quality for the Choice of the 'Clinical RBE' in Fast Neutron Therapy , 1994 .

[17]  P. Colautti,et al.  Lineal energy calibration of mini tissue-equivalent gas-proportional counters (TEPC) , 2013 .