Evaluating the interaction of a tracheobronchial stent in an ovine in-vivo model
暂无分享,去创建一个
Peter E. McHugh | Barry O’Brien | Stefan Jockenhoevel | Anja Lena Thiebes | Mark Bruzzi | Donnacha J McGrath | P. McHugh | S. Jockenhoevel | M. Bruzzi | A. Thiebes | D. J. McGrath | C. Cornelissen | B. O'brien | Christian G. Cornelissen | Donnacha J. McGrath | B. O'Brien
[1] Peter E. McHugh,et al. An ovine in vivo framework for tracheobronchial stent analysis , 2017, Biomechanics and modeling in mechanobiology.
[2] U. Steinseifer,et al. PulmoStent: In Vitro to In Vivo Evaluation of a Tissue Engineered Endobronchial Stent , 2017, Annals of Biomedical Engineering.
[3] Donnacha J McGrath,et al. Selection and fabrication of a non-woven polycarbonate urethane cover for a tissue engineered airway stent. , 2016, International journal of pharmaceutics.
[4] U. Steinseifer,et al. Evaluation of cover effects on bare stent mechanical response. , 2016, Journal of the mechanical behavior of biomedical materials.
[5] E. Peña,et al. On Studying the Interaction Between Different Stent Models and Rabbit Tracheal Tissue: Numerical, Endoscopic and Histological Comparison , 2016, Annals of Biomedical Engineering.
[6] A. Didier,et al. Integration of interventional bronchoscopy in the management of lung cancer , 2015, European Respiratory Review.
[7] Xiaohu Guo,et al. Sensitivity of tumor motion simulation accuracy to lung biomechanical modeling approaches and parameters , 2015, Physics in medicine and biology.
[8] Nassir Navab,et al. Patient-Specific Biomechanical Model for the Prediction of Lung Motion From 4-D CT Images , 2015, IEEE Transactions on Medical Imaging.
[9] M. Doblaré,et al. Simulation of swallowing dysfunction and mechanical ventilation after a Montgomery T-tube insertion , 2015, Computer methods in biomechanics and biomedical engineering.
[10] P E McHugh,et al. Nitinol stent design - understanding axial buckling. , 2014, Journal of the mechanical behavior of biomedical materials.
[11] D. Naidich,et al. Multidetector CT evaluation of airway stents: what the radiologist should know. , 2014, Radiographics : a review publication of the Radiological Society of North America, Inc.
[12] U. Steinseifer,et al. Manufacturing of biocompatible nonwoven structures by using spray atomization of dissolved polymers , 2014 .
[13] M. Martínez,et al. Modelling the air mass transfer in a healthy and a stented rabbit trachea: CT-images, computer simulations and experimental study ☆ , 2014 .
[14] Ríona Ní Ghriallais,et al. Self-expanding stent modelling and radial force accuracy , 2014, Computer methods in biomechanics and biomedical engineering.
[15] B. Ramezanzadeh,et al. Studying the effects of chain extenders chemical structures on the adhesion and mechanical properties of a polyurethane adhesive , 2013 .
[16] J. A. Grogan,et al. Optimizing the design of a bioabsorbable metal stent using computer simulation methods. , 2013, Biomaterials.
[17] P Segers,et al. Filling the void: a coalescent numerical and experimental technique to determine aortic stent graft mechanics. , 2013, Journal of biomechanics.
[18] Joris Degroote,et al. A computational method to assess the in vivo stresses and unloaded configuration of patient-specific blood vessels , 2013, J. Comput. Appl. Math..
[19] Claire Conway,et al. A Computational Test-Bed to Assess Coronary Stent Implantation Mechanics Using a Population-Specific Approach , 2012 .
[20] E. Wolf,et al. Domestic animal models for biomedical research. , 2012, Reproduction in domestic animals = Zuchthygiene.
[21] Hojoong Kim,et al. Results of interventional bronchoscopy in the management of postoperative tracheobronchial stenosis. , 2012, The Journal of thoracic and cardiovascular surgery.
[22] Xiudong Lei,et al. Respiratory infections increase the risk of granulation tissue formation following airway stenting in patients with malignant airway obstruction. , 2012, Chest.
[23] E Peña,et al. Influence of geometrical parameters on radial force during self-expanding stent deployment. Application for a variable radial stiffness stent. , 2012, Journal of the mechanical behavior of biomedical materials.
[24] Manuel Doblaré,et al. FE simulation of human trachea swallowing movement before and after the implantation of an endoprothesis , 2011 .
[25] Adil Al-Mayah,et al. Toward efficient biomechanical-based deformable image registration of lungs for image-guided radiotherapy. , 2011, Physics in medicine and biology.
[26] M Doblaré,et al. FSI analysis of a human trachea before and after prosthesis implantation. , 2011, Journal of biomechanical engineering.
[27] Brian B. Avants,et al. Evaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge , 2011, IEEE Transactions on Medical Imaging.
[28] W A Wall,et al. Material model of lung parenchyma based on living precision-cut lung slice testing. , 2011, Journal of the mechanical behavior of biomedical materials.
[29] Fu-Tsai Chung,et al. An outcome analysis of self-expandable metallic stents in central airway obstruction: a cohort study , 2011, Journal of cardiothoracic surgery.
[30] M. Hsieh,et al. Granulation Tissue Formation following Dumon Airway Stenting: The Influence of Stent Diameter , 2011, The Thoracic and cardiovascular surgeon.
[31] M Doblaré,et al. FSI Analysis of a healthy and a stenotic human trachea under impedance-based boundary conditions. , 2011, Journal of biomechanical engineering.
[32] Heinz Handels,et al. Statistical Modeling of 4D Respiratory Lung Motion Using Diffeomorphic Image Registration , 2011, IEEE Transactions on Medical Imaging.
[33] A. Majid,et al. Treatment of airway complications following lung transplantation. , 2011, Archivos de bronconeumologia.
[34] F. Bhora,et al. Timely airway stenting improves survival in patients with malignant central airway obstruction. , 2010, The Annals of thoracic surgery.
[35] Adil Al-Mayah,et al. Deformable image registration of heterogeneous human lung incorporating the bronchial tree. , 2010, Medical physics.
[36] M. Doblaré,et al. Patient-specific models of human trachea to predict mechanical consequences of endoprosthesis implantation , 2010, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.
[37] K. Brock. Results of a multi-institution deformable registration accuracy study (MIDRAS). , 2010, International journal of radiation oncology, biology, physics.
[38] M Doblaré,et al. Experimental characterization and constitutive modeling of the mechanical behavior of the human trachea. , 2010, Medical engineering & physics.
[39] Eric A Hoffman,et al. Supine and prone differences in regional lung density and pleural pressure gradients in the human lung with constant shape. , 2009, Journal of applied physiology.
[40] Heinz Handels,et al. Patient-specific finite element modeling of respiratory lung motion using 4D CT image data. , 2009, Medical physics.
[41] C. Dooms,et al. Performance of Fully Covered Self-Expanding Metallic Stents in Benign Airway Strictures , 2009, Respiration.
[42] H. Hautmann,et al. Elastic deformation properties of implanted endobronchial wire stents in benign and malignant bronchial disease: A radiographic in vivo evaluation , 1999, CardioVascular and Interventional Radiology.
[43] Fu-Tsai Chung,et al. Factors leading to tracheobronchial self-expandable metallic stent fracture. , 2008, The Journal of thoracic and cardiovascular surgery.
[44] Heinz Handels,et al. Generation of a Mean Motion Model of the Lung Using 4D-CT Image Data , 2008, VCBM.
[45] Timon Rabczuk,et al. Fluid–structure interaction in lower airways of CT‐based lung geometries , 2008 .
[46] V. Bowles,et al. Biomedical applications of sheep models: from asthma to vaccines. , 2008, Trends in biotechnology.
[47] D. Harpole,et al. Outcomes of tracheobronchial stents in patients with malignant airway disease. , 2005, The Annals of thoracic surgery.
[48] K. Müller,et al. Reaction patterns of the tracheobronchial wall to implanted noncovered metal stents. , 2005, Chest.
[49] B. Shariat,et al. Simulation of lung behaviour with finite elements: influence of bio-mechanical parameters , 2005, Third International Conference on Medical Information Visualisation--BioMedical Visualisation.
[50] M. Noppen,et al. Removal of covered self-expandable metallic airway stents in benign disorders: indications, technique, and outcomes. , 2005, Chest.
[51] Klaus Gärtner,et al. Meshing Piecewise Linear Complexes by Constrained Delaunay Tetrahedralizations , 2005, IMR.
[52] T. Gildea,et al. Removal of self-expandable metallic stents: is it possible? , 2004, Seminars in respiratory and critical care medicine.
[53] Tom Duerig,et al. Self-expanding nitinol stents: material and design considerations , 2004, European Radiology.
[54] Atul C Mehta,et al. Self-expandable metallic airway stents and flexible bronchoscopy: long-term outcomes analysis. , 2003, Chest.
[55] W. Fegeler,et al. Bacteria and Granulation Tissue Associated With Montgomery T‐Tubes , 2003, The Laryngoscope.
[56] Eric A Mair,et al. Complications of Tracheobronchial Airway Stents , 2003, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.
[57] M. Wax,et al. Metallic Tracheal Stents: Complications Associated with Long-Term Use in the Upper Airway , 2002, The Annals of otology, rhinology, and laryngology.
[58] R. Gialletti,et al. Long-term safety and tolerance of silicone and self-expandable airway stents: an experimental study. , 2000, The Annals of thoracic surgery.
[59] Ferdinando Auricchio,et al. Shape-memory alloys: macromodelling and numerical simulations of the superelastic behavior , 1997 .
[60] S. Codd,et al. Tensile stiffness of ovine tracheal wall. , 1994, Journal of applied physiology.
[61] E. Bergofsky,et al. How alterations in pleural pressure influence esophageal pressure. , 1984, Journal of applied physiology: respiratory, environmental and exercise physiology.