Effects of water flow volume on the isolation of bacteria from motion sensor faucets

Water outlets for washing hands and medical equipment are essential for preventing hospital infection. The present study clarified the effects of water flow volume on the identification and quantitative evaluation of bacteria found around spouts in the 17 hand-washing stations. Pseu-domonas aeruginosa was detected from 4 sta-tions before adjustment and 2 after adjustment. Although no significant difference was identified in the detection rate of P. aeruginosa (p = 0.368), when combining P. aeruginosa and glucose non-fermentative Gram-negative bacilli (NFB), the number of stations with P. aeruginosa and/or NFB decreased significantly from 15 before adjustment to 9 after adjustment (p = 0.023). Before adjust-ment, quantity of bacteria was “2+” for 3 stations and “1+” for 7 stations, but was “1+” for 3 stations and “2+” for 0 stations after adjustment. These results show that quantity of bacteria could be reduced from spouts by adjusting flow volume. These results were also supported by experiments for cleanliness using Adenosine 5’-triphosphate bioluminescence me- thod.

[1]  B. Souweine,et al.  Pseudomonas aeruginosa and Pseudomonas putida outbreak associated with contaminated water outlets in an oncohaematology paediatric unit. , 2007, The Journal of hospital infection.

[2]  H. Ayçiçek,et al.  Comparison of results of ATP bioluminescence and traditional hygiene swabbing methods for the determination of surface cleanliness at a hospital kitchen. , 2006, International journal of hygiene and environmental health.

[3]  M. Exner,et al.  Pseudomonas aeruginosa outbreak in a haematology-oncology unit associated with contaminated surface cleaning equipment. , 2002, The Journal of hospital infection.

[4]  W A Rutala,et al.  Surface disinfection: should we do it? , 2001, The Journal of hospital infection.

[5]  Teresa C. Horan,et al.  Guideline for Prevention of Surgical Site Infection, 1999 , 1999, Infection Control & Hospital Epidemiology.

[6]  P. Berche,et al.  Outbreak of nosocomial urinary tract infections due to Pseudomonas aeruginosa in a paediatric surgical unit associated with tap-water contamination. , 1998, The Journal of hospital infection.

[7]  E. Maubec,et al.  Multi-resistant Pseudomonas aeruginosa outbreak associated with contaminated tap water in a neurosurgery intensive care unit. , 1998, The Journal of hospital infection.

[8]  H. J. Kolmos,et al.  Outbreak of infection in a burns unit due to Pseudomonas aeruginosa originating from contaminated tubing used for irrigation of patients. , 1993, The Journal of hospital infection.

[9]  B. Doebbeling,et al.  Outbreak of Pseudomonas aeruginosa infections in a surgical intensive care unit: probable transmission via hands of a health care worker. , 1993, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[10]  J. Garner,et al.  CDC guidelines for the prevention and control of nosocomial infections. Guideline for handwashing and hospital environmental control, 1985. Supersedes guideline for hospital environmental control published in 1981. , 1986, American journal of infection control.

[11]  Garner Js,et al.  CDC Guideline for Handwashing and Hospital Environmental Control, 1985 , 1986, Infection Control.