One-Terminal Impedance Fault Location Algorithm for Single Phase to Earth Fault of Transmission Line

Considering that the single-phase to earth fault is the main fault type on overhead transmission lines, the single-phase reclosure (SPR) scheme is applied widely to improve the stability of power system in China. Utilizing one-terminal post-fault measurements before the faulty phase is tripped and the measurements of the sound phases when the tripped faulty phase is waiting for SPR, the fault resistance and remote end source impedances can be calculated exactly, and a novel one-terminal impedance fault location algorithm based on SPR for the single-phase to earth fault is presented. By using alternative transient program (ATP), a distributed parameter line model based on the real transmission system parameters is employed for demonstrating the effectiveness of the new method, and the simulation results have shown the good performance of the proposed algorithm.

[1]  P. A. Crossley,et al.  Practical experience with travelling wave fault locators on Scottish Power's 275 & 400 kV transmission system , 1997 .

[2]  Jun Qi,et al.  An accurate fault location algorithm for transmission line based on R–L model parameter identification , 2005 .

[3]  Adly A. Girgis,et al.  A new fault location technique for two- and three-terminal lines , 1992 .

[4]  Jan Izykowski,et al.  Improved unsynchronized two-end algorithm for locating faults in power transmission lines , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[5]  J. Stenzel,et al.  Investigation of practical problems for digital fault location algorithms based on EMTP simulation , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[6]  Damir Novosel,et al.  Unsynchronized two-terminal fault location estimation , 1996 .

[7]  Murari Mohan Saha,et al.  An Accurate Fault Locator with Compensation for Apparent Reactance in the Fault Resistance Resulting from Remote-End Infeed , 1985, IEEE Power Engineering Review.

[8]  Zaibin Jiao,et al.  A Novel Single-Phase Adaptive Reclosure Scheme for Transmission Lines With Shunt Reactors , 2009, IEEE Transactions on Power Delivery.

[9]  Yuan Liao,et al.  Optimal Estimate of Transmission Line Fault Location Considering Measurement Errors , 2007, IEEE Transactions on Power Delivery.

[10]  Ying-Hong Lin,et al.  An adaptive PMU based fault detection/location technique for transmission lines. I. Theory and algorithms , 2000 .

[11]  I. Zamora,et al.  Fault location on two-terminal transmission lines based on voltages , 1996 .

[12]  A. T. Johns,et al.  A novel fault locator based on the detection of fault generated high frequency transients , 1997 .

[13]  T. Takagi,et al.  Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data , 1982, IEEE Power Engineering Review.

[14]  Milenko B. Djurić,et al.  Distance protection and fault location utilizing only phase current phasors , 1998 .

[15]  M. A. Street,et al.  Global Positioning System applications at the Bonneville Power Administration , 1995, IEEE Technical Applications Conference and Workshops. Northcon/95. Conference Record.

[16]  A. T. Johns,et al.  Accurate fault location technique for power transmission lines , 1990 .

[17]  T. Adu A New Transmission Line Fault-Locating System , 2001, IEEE Power Engineering Review.

[18]  P. F. Gale,et al.  Travelling wave fault locator experience on Eskom's transmission network , 2001 .

[19]  P. A. Crossley,et al.  Fault location on a transmission line using high frequency travelling waves measured at a single line end , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[20]  Wu Jian-bo Present achievements and prospects of single-pole adaptive reclosure , 2007 .