In 1950, Allan P. Bloxsom (1901-1991), a pediatrician at the St Joseph Hospital in Houston, intro- duced his positive pressure oxygen air lock (AL) for the delivery room resuscitation of the asphyxiated newborn. The infant's entire body was placed into a cylindrical steel chamber that was tightly sealed and infused with warmed humidified 60% oxygen. The positive pressure within the AL was cycled between 1 and 3 lb/in 2 at 1-minute intervals to simulate the intrauterine pressures during the second stage of labor. Bloxsom developed the AL device in response to his hypothesis that the contrac- tions of labor help to "condition: the infant for extrauter- ine survival. Parmalee said that the AL "certainly locks the infant up, safe from meddlesome and unintelligent treatment." When clear plastic versions of the AL became commer- cially available, it received widespread use in delivery rooms and newborn nurseries throughout the United States. In 1953, Apgar and Kreiselman produced apnea in adult dogs using pentobarbital and a muscle relaxant, and found that the AL device was unsuccessful with the oxygenation and ventilation of the animals. In 1954, Townsend in Rochester, New York, reported on his experience with the AL in 150 premature infants. He concluded that the AL should be "more accurately referred to as an oxygenator" and that, "the truly apneic infant cannot be maintained in a acyanotic state by the AL." The AL was finally subjected to the scrutiny of a randomized, controlled clinical trial that was published in 1956. Reichelderfer and Nitowski at Johns Hopkins randomized 171 infants to receive care in the AL or in an Isolette. Routine resuscitation, including positive pres- sure ventilation, was administered, as needed, to both study groups before placement into the AL or Isolette (Air Shields Inc, Hatboro, PA). They did not find any differences in the outcomes of the 2 study groups. By the mid 1950s, new information linking oxygen therapy and retrolental fibroplasia, led to a rapid decline in the use of the AL, even before the publication of the randomized trial. Pediatrics 2001;108(6). URL: http://www.pediatrics. org/cgi/content/full/108/6/e116; Bloxsom air lock, neonatal resuscitation, prematurity.
[1]
P. Safar.
STUDIES ON RESUSCITATION.
,
1964
.
[2]
H. Nitowsky,et al.
A controlled study of the use of the Bloxsom air lock.
,
1956,
Pediatrics.
[3]
Townsend Eh.
The oxygen air pressure lock. II. Antiatelectatic action in the neonatal period.
,
1955
.
[4]
E. H. Townsend.
The Oxygen Air Pressure Lock: I. Clinical observations on its use during the neonatal period
,
1954,
Obstetrics and gynecology.
[5]
A. Bloxsom,et al.
Neonatal infant mortality; before and after the use of the air lock for the treatment of newborn infants in a large maternity hospital.
,
1954,
American journal of obstetrics and gynecology.
[6]
V. Apgar,et al.
Studies on resuscitation; an experimental evaluation of the Bloxsom air lock.
,
1953,
American journal of obstetrics and gynecology.
[7]
H. Prystowsky,et al.
A study of one hundred fifty-three infants placed in the positive pressure oxygen-air lock.
,
1952,
American journal of obstetrics and gynecology.
[8]
A. Bloxsom.
Asphyxia neonatorum; new method of resuscitation.
,
1951,
Journal of the American Medical Association.
[9]
A. Bloxsom,et al.
Resuscitation of the newborn infant; use of the positive pressure oxygen-air lock.
,
1950,
The Journal of pediatrics.
[10]
H. Ehrenfest.
The difficulty in beginning respiration seen in infants delivered by cesarean section
,
1943
.
[11]
A. Bloxsom.
The difficulty in beginning respiration seen ininfants delivered by cesarean section
,
1942
.