Baseload electricity from wind via compressed air energy storage (CAES)

This study investigates two methods of transforming intermittent wind electricity into firm baseload capacity: (1) using electricity from natural gas combined-cycle (NGCC) power plants and (2) using electricity from compressed air energy storage (CAES) power plants. The two wind models are compared in terms of capital and electricity costs, CO2 emissions, and fuel consumption rates. The findings indicate that the combination of wind and NGCC power plants is the lowest-cost method of transforming wind electricity into firm baseload capacity power supply at current natural gas prices (∼$6/GJ). However, the electricity supplied by wind and CAES power plants becomes economically competitive when the cost of natural gas for electric producers is $10.55/GJ or greater. In addition, the Wind-CAES system has the lowest CO2 emissions (93% and 71% lower than pulverized coal power plants and Wind-NGCC, respectively) and the lowest fuel consumption rates (9 and 4 times lower than pulverized coal power plants and Wind-NGCC, respectively). As such, the large-scale introduction of Wind-CAES systems in the U.S. appears to be the prudent long-term choice once natural gas price volatility, costs, and climate impacts are all considered.

[1]  A. J. Cavallo,et al.  Cost effective seasonal storage of wind energy , 1995 .

[2]  Paul Denholm,et al.  Emissions and energy efficiency assessment of baseload wind energy systems. , 2005, Environmental science & technology.

[3]  Jeffery B. Greenblatt,et al.  Baseload wind energy: modeling the competition between gas turbines and compressed air energy storage for supplemental generation , 2007 .

[4]  L. L. Wendell,et al.  An assessment of the available windy land area and wind energy potential in the contiguous United States , 1991 .

[5]  Hazlie Mokhlis,et al.  Emergence of energy storage technologies as the solution for reliable operation of smart power systems: A review , 2013 .

[6]  Joseph F. DeCarolis,et al.  The economics of large-scale wind power in a carbon constrained world , 2006 .

[7]  Alfred J. Cavallo,et al.  Controllable and affordable utility-scale electricity from intermittent wind resources and compressed air energy storage (CAES) , 2007 .

[8]  Jimmy Peress,et al.  Working with non-ideal gases , 2003 .

[9]  Mark Z. Jacobson,et al.  A PATH TO SUSTAINABLE ENERGY , 2009 .

[10]  J. Dutoit The Fourth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC) , 2007 .

[11]  V. Fthenakis,et al.  Coupling PV and CAES power plants to transform intermittent PV electricity into a dispatchable electricity source , 2008 .

[12]  Jay Apt,et al.  Economics of compressed air energy storage to integrate wind power: A case study in ERCOT , 2011 .

[13]  Vladimir Strezov,et al.  Assessment of utility energy storage options for increased renewable energy penetration , 2012 .

[14]  C. L. Archer,et al.  Spatial and temporal distributions of U.S. winds and wind power at 80 m derived from measurements , 2003 .

[15]  C. L. Archer,et al.  Evaluation of global wind power , 2005 .

[16]  Mark A Delucchi,et al.  A path to sustainable energy by 2030. , 2009, Scientific American.

[17]  Mark Z. Jacobson,et al.  Supplying Baseload Power and Reducing Transmission Requirements by Interconnecting Wind Farms , 2007 .