Glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline.

A sensitive and selective amperometric glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline (PANI) was investigated. Poly (m-phenylenediamine) (PMPD), which was employed as an anti-interferent barrier and a protective layer to platinum microparticles, was deposited onto platinum-modified PANI in the presence of glucose oxidase. The morphology of PANI, Pt/PANI and PMPD-GOD/Pt/PANI were investigated by scanning electron microscopy. The results show that PANI has a nano-fibrous morphology. The enzyme electrode exhibits excellent response performance to glucose with linear range from 2 x 10(-6) to 12 x 10(-3) M and fast response time within 7s. Due to the selective permeability of PMPD, the enzyme electrode also shows good anti-interference to uric acid and ascorbic acid. The Michaelis-Menten constant km and the maximum current density imax of the enzyme electrode were 9.34 x 10(-3) M and 917.43 microA cm(-2), respectively. Furthermore, this glucose biosensor also has good stability and reproducibility.

[1]  Michio Matsumura,et al.  A new method for dispersing palladium microparticles in conducting polymer films and its application to biosensors , 1997 .

[2]  Jing‐Juan Xu,et al.  Amperometric glucose sensor based on glucose oxidase immobilized in electrochemically generated poly(ethacridine) , 2000 .

[3]  C. Lamy,et al.  Electrocatalytic reduction of dioxygen at platinum particles dispersed in a polyaniline film , 2000 .

[4]  M. Trojanowicz,et al.  Bilayer lipid membrane glucose biosensors with improved stability and sensitivity , 2001 .

[5]  M. Umaña,et al.  Protein-modified electrodes. The glucose oxidase/polypyrrole system , 1986 .

[6]  W. J. Sung,et al.  A glucose oxidase electrode based on electropolymerized conducting polymer with polyanion-enzyme conjugated dopant. , 2000, Analytical chemistry.

[7]  C. Choi,et al.  Glucose sensor using a microfabricated electrode and electropolymerized bilayer films. , 2002, Biosensors & bioelectronics.

[8]  M. Smyth,et al.  Electropolymerised o-phenylenediamine film as means of immobilising lactate oxidase for a L-lactate biosensor. , 1993, Talanta.

[9]  Antonio Guerrieri,et al.  Electrosynthesized Bilayer Polymeric Membrane for Effective Elimination of Electroactive Interferents in Amperometric Biosensors , 1995 .

[10]  C. Lamy,et al.  Electrooxidation of β-D(+)glucose on bare and u.p.d. modified platinum particles dispersed in polyaniline , 1999 .

[11]  G. Pistoia,et al.  Factors affecting the growth of thick polyaniline films by the cyclic voltammetry technique , 1989 .

[12]  C. Lamy,et al.  Electrocatalytic oxidation of methanol on platinum dispersed in polyaniline conducting polymers , 1989 .

[13]  E. Magner,et al.  Trends in electrochemical biosensors. , 1998, The Analyst.

[14]  Plamen Atanasov,et al.  Development of needle-type glucose sensor with high selectivity , 1998 .

[15]  Christopher R. Lowe,et al.  Enzyme entrapment in electrically conducting polymers. Immobilisation of glucose oxidase in polypyrrole and its application in amperometric glucose sensors , 1986 .

[16]  Ihab Abdel-Hamid,et al.  Development of a needle-type biosensor for intravascular glucose monitoring , 1995 .

[17]  Hongyuan Chen,et al.  Electrocatalytic reduction of hydrogen peroxide at platinum microparticles dispersed in a poly(o-phenylenediamine) film , 1999 .

[18]  N. Comisso,et al.  Cyclic potential sweep electropolymerization of aniline: The role of anions in the polymerization mechanism , 1988 .

[19]  G. S. Wilson,et al.  Rotating ring-disk enzyme electrode for surface catalysis studies. , 1976, Analytical chemistry.

[20]  G. Wallace,et al.  Conducting polymers and the bioanalytical sciences: new tools for biomolecular communication. A review. , 1996, The Analyst.

[21]  I. Losito,et al.  Double electropolymer modified platinum electrode to follow the kinetic process H2O2 + ascorbic acid. Influence of the reaction on amperometric biosensor applications , 1996 .

[22]  I Karube,et al.  Thin-film glucose biosensor based on plasma-polymerized film: simple design for mass production. , 2000, Analytical chemistry.

[23]  L. Chen,et al.  Bioinorganic composites for enzyme electrodes. , 2001, Analytical chemistry.

[24]  K. Aoki,et al.  The steady-state current at microcylinder electrodes modified by enzymes immobilized in conducting or non-conducting material , 2002 .

[25]  Jonathan M. Cooper,et al.  A review of the immobilization of enzymes in electropolymerized films , 1993 .

[26]  H. Dinh,et al.  Characteristics of the polyaniline anodic pre-peak , 1999 .

[27]  Mu Shaolin,et al.  BIOELECTROCHEMICAL RESPONSES OF THE POLYANILINE GLUCOSE OXIDASE ELECTRODE , 1991 .

[28]  I. Becerik,et al.  Glucose sensitivity of platinum-based alloys incorporated in polypyrrole films at neutral media , 2001 .