Ultra-Fast Displaying Spectral Domain Optical Doppler Tomography System Using a Graphics Processing Unit

We demonstrate an ultrafast displaying Spectral Domain Optical Doppler Tomography system using Graphics Processing Unit (GPU) computing. The calculation of FFT and the Doppler frequency shift is accelerated by the GPU. Our system can display processed OCT and ODT images simultaneously in real time at 120 fps for 1,024 pixels × 512 lateral A-scans. The computing time for the Doppler information was dependent on the size of the moving average window, but with a window size of 32 pixels the ODT computation time is only 8.3 ms, which is comparable to the data acquisition time. Also the phase noise decreases significantly with the window size. Since the performance of a real-time display for OCT/ODT is very important for clinical applications that need immediate diagnosis for screening or biopsy. Intraoperative surgery can take much benefit from the real-time display flow rate information from the technology. Moreover, the GPU is an attractive tool for clinical and commercial systems for functional OCT features as well.

[1]  J. Fujimoto,et al.  Ultrahigh speed spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second. , 2008, Optics express.

[2]  David Huang,et al.  Handbook of optical coherence tomography. , 2003, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[3]  Jeehyun Kim,et al.  Full-range k-domain linearization in spectral-domain optical coherence tomography. , 2011, Applied optics.

[4]  Adrian Mariampillai,et al.  Doppler optical cardiogram gated 2D color flow imaging at 1000 fps and 4D in vivo visualization of embryonic heart at 45 fps on a swept source OCT system. , 2007, Optics express.

[5]  Shuichi Makita,et al.  Quantitative retinal-blood flow measurement with three-dimensional vessel geometry determination using ultrahigh-resolution Doppler optical coherence angiography. , 2008, Optics letters.

[6]  Yuuki Watanabe Real time processing of Fourier domain optical coherence tomography with fixed-pattern noise removal by partial median subtraction using a graphics processing unit. , 2012, Journal of biomedical optics.

[7]  Jeehyun Kim,et al.  Hemoglobin contrast in magnetomotive optical Doppler tomography. , 2006, Optics letters.

[8]  Brian C. Wilson,et al.  Improved phase-resolved optical Doppler tomography using the Kasai velocity estimator and histogram segmentation , 2002 .

[9]  Yuuki Watanabe,et al.  Real-time display on Fourier domain optical coherence tomography system using a graphics processing unit. , 2009, Journal of biomedical optics.

[10]  Kang Zhang,et al.  Real-time intraoperative 4D full-range FD-OCT based on the dual graphics processing units architecture for microsurgery guidance , 2011, Biomedical optics express.

[11]  Julius Pekar,et al.  High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I): System design, signal processing, and performance. , 2003, Optics express.

[12]  B. Vakoc,et al.  >400 kHz repetition rate wavelength-swept laser and application to high-speed optical frequency domain imaging. , 2010, Optics letters.

[13]  Yuuki Watanabe,et al.  Real-time processing for full-range Fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units. , 2010, Applied optics.

[14]  Woonggyu Jung,et al.  Quantification of a three-dimensional velocity vector using spectral-domain Doppler optical coherence tomography. , 2007, Optics letters.

[15]  Kang Zhang,et al.  Real-time 4D signal processing and visualization using graphics processing unit on a regular nonlinear-k Fourier-domain OCT system , 2010, Optics express.