BACKGROUND Cardiac perforation by a transvenous lead is an uncommon but serious complication. Delayed perforation, defined as migration and perforation of an implanted lead at least 1 mo after implantation, is exceedingly rare and prone to underdiagnosis, and its optimal management is currently unclear. We report an uneventful transvenous extraction of an active fixation lead that led to delayed perforation of the right atrium, pericardium, and lung, disclosed 2 mo after implantation. CASE SUMMARY A 61-year-old woman with atrial lead perforation was transferred to our center. She had a dual-chamber pacemaker with active fixation leads implanted 8 mo previously. At 2 mo after implantation, she complained of chest pain and hemoptysis. Chest computed tomography revealed atrial lead migration into the lung. No pericardial or pleural effusion was detected. She underwent transvenous lead extraction in the electrophysiology room with surgical backup. The percutaneous subxiphoid pericardial puncture was performed first, and a pigtail catheter was left in the pericardial sac throughout the procedure. Then, a new active fixation lead was implanted at a different site with less tension. After the active screw was retracted, the culprit atrial lead was explanted successfully with simple traction. There were no complications during or after the procedure. The patient recovered well and follow-up was uneventful. CONCLUSION Percutaneous management of perforated active fixation lead outside the pericardial sac under surgical backup is safe and effective.

[1]  G. Weisz,et al.  The management of cardiac implantable electronic device lead perforations: a multicentre study. , 2019, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[2]  M. Shoda,et al.  2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. , 2017, Heart rhythm.

[3]  R. Rajani,et al.  Diagnosis and management of iatrogenic cardiac perforation caused by pacemaker and defibrillator leads , 2016, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[4]  D. Corrado,et al.  Incidence, Management, and Prevention of Right Ventricular Perforation by Pacemaker and Implantable Cardioverter Defibrillator Leads , 2014, Pacing and clinical electrophysiology : PACE.

[5]  L. Sinak,et al.  Outcomes of Lead Revision for Myocardial Perforation After Cardiac Implantable Electronic Device Placement , 2014, Journal of cardiovascular electrophysiology.

[6]  Daniel Steven,et al.  Epicardial ventricular tachycardia ablation a multicenter safety study. , 2010, Journal of the American College of Cardiology.

[7]  Maria Grazia Bongiorni,et al.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). , 2009, Heart rhythm.

[8]  M. Haissaguerre,et al.  Management of subacute and delayed right ventricular perforation with a pacing or an implantable cardioverter-defibrillator lead. , 2008, The American journal of cardiology.

[9]  G. Religa,et al.  Subacute cardiac perforations associated with active fixation leads. , 2008, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[10]  V. Jain,et al.  Prevalence and Characterization of Asymptomatic Pacemaker and ICD Lead Perforation on CT , 2007, Pacing and clinical electrophysiology : PACE.

[11]  Yaariv Khaykin,et al.  Delayed Lead Perforation: A Disturbing Trend , 2005, Pacing and clinical electrophysiology : PACE.

[12]  A. Chauhan,et al.  An unusual presentation of delayed cardiac perforation caused by atrial screw-in lead , 2003, Heart.

[13]  A. d'Avila,et al.  A New Technique to Perform Epicardial Mapping in the Electrophysiology Laboratory , 1996, Journal of cardiovascular electrophysiology.