Safety measurements for heating of instruments for cardiovascular interventions in magnetic particle imaging (MPI) - first experiences.

Magnetic particle imaging (MPI) has emerged as a new imaging method with the potential of delivering images of high spatial and temporal resolutions and free of ionizing radiation. Recent studies demonstrated the feasibility of differentiation between signal-generating and non-signal-generating devices in Magnetic Particle Spectroscopy (MPS) and visualization of commercially available catheters and guide-wires in MPI itself. Thus, MPI seems to be a promising imaging tool for cardiovascular interventions. Several commercially available catheters and guide-wires were tested in this study regarding heating. Heating behavior was correlated to the spectra generated by the devices and measured by the MPI. The results indicate that each instrument should be tested separately due to the wide spectrum of measured temperature changes of signal-generating instruments, which is up to 85°C in contrast to non-signal-generating devices. Development of higher temperatures seems to be a limitation for the use of these devices in cardiovascular interventions.

[1]  M. Bock,et al.  MR‐guided intravascular interventions: Techniques and applications , 2008, Journal of magnetic resonance imaging : JMRI.

[2]  B Gleich,et al.  Three-dimensional real-time in vivo magnetic particle imaging , 2009, Physics in medicine and biology.

[3]  Marlitt Erbe Magnetic Particle Imaging , 2014 .

[4]  Fritz Schick,et al.  Heating of metallic implants and instruments induced by gradient switching in a 1.5-Tesla whole-body unit. , 2007, Journal of magnetic resonance imaging : JMRI.

[5]  Jürgen Rahmer,et al.  Fast MPI Demonstrator with Enlarged Field of View , 2010 .

[6]  Bernhard Gleich,et al.  Tomographic imaging using the nonlinear response of magnetic particles , 2005, Nature.

[7]  J. Stainsby,et al.  Practical aspects of MR imaging in the presence of conductive guide wires , 2010, Physics in medicine and biology.

[8]  Emine Ulku Saritas,et al.  Safety Limits for Human-Size Magnetic Particle Imaging Systems , 2012 .

[9]  Thorsten M. Buzug,et al.  Fundamentals and Potential of Magnetic Particle Imaging , 2013, Current Cardiovascular Imaging Reports.

[10]  B Gleich,et al.  Experimental results on fast 2D-encoded magnetic particle imaging , 2008, Physics in medicine and biology.

[11]  B Gleich,et al.  A simulation study on the resolution and sensitivity of magnetic particle imaging , 2007, Physics in medicine and biology.

[12]  Matthias Graeser,et al.  Magnetic particle imaging: introduction to imaging and hardware realization. , 2012, Zeitschrift fur medizinische Physik.

[13]  T M Buzug,et al.  [Magnetic particle imaging (MPI)]. , 2012, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[14]  M. Eagleton,et al.  Intraprocedural imaging: flat panel detectors, rotational angiography, FluoroCT, IVUS, or still the portable C-arm? , 2010, Journal of vascular surgery.

[15]  Gunnar Schütz,et al.  The Potential of Magnetic Particle Imaging in the Competitive Environment of Cardiac Diagnostics , 2012 .

[16]  Shuji Usui,et al.  Dependence of RF heating on SAR and implant position in a 1.5T MR system. , 2007, Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine.

[17]  George Loudos,et al.  Emerging technologies for image guidance and device navigation in interventional radiology. , 2012, Medical physics.

[18]  Ronald L. Arenson,et al.  RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI. , 2011, Academic radiology.

[19]  Alan McMillan,et al.  Increasing the oscillation frequency of strong magnetic fields above 101 kHz significantly raises peripheral nerve excitation thresholds. , 2012, Medical physics.

[20]  R. Günther,et al.  Magnetic Resonance–Guided Cardiac Interventions Using Magnetic Resonance–Compatible Devices: A Preclinical Study and First-in-Man Congenital Interventions , 2010, Circulation. Cardiovascular interventions.

[21]  Gabriel Acevedo-Bolton,et al.  MR imaging during endovascular procedures: An evaluation of the potential for catheter heating , 2009, Magnetic resonance in medicine.

[22]  Gilles Soulez,et al.  Three-dimensional C-arm cone-beam CT: applications in the interventional suite. , 2008, Journal of vascular and interventional radiology : JVIR.

[23]  W. Nitz,et al.  On the heating of linear conductive structures as guide wires and catheters in interventional MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[24]  Reza Razavi,et al.  Magnetic Resonance–Guided Cardiac Interventions Using Magnetic Resonance–Compatible DevicesClinical Perspective , 2010 .

[25]  Bernhard Gleich,et al.  Magnetic Particle imaging : Visualization of Instruments for Cardiovascular Intervention 1 , 2012 .

[26]  Thorsten M Buzug,et al.  Toward cardiovascular interventions guided by magnetic particle imaging: First instrument characterization , 2013, Magnetic resonance in medicine.

[27]  M. Saeed,et al.  MR fluoroscopy in vascular and cardiac interventions (review) , 2011, The International Journal of Cardiovascular Imaging.

[28]  Frank K Wacker,et al.  MR image-guided endovascular procedures with the ultrasmall superparamagnetic iron oxide SH U 555 C as an intravascular contrast agent: study in pigs. , 2003, Radiology.