Solar shading control strategies in cold climates – Heating, cooling demand and daylight availability in office spaces

Modern office buildings often have large glazed areas. Incident solar radiation can lead to large cooling demands during hot periods although the solar radiation can help reduce heating demands during cool periods. Previous studies have shown that large parts of the net energy demand of an office building is related to window heat loss and cooling demands induced by solar irradiance. In this article, the authors found that, even in what traditionally has been considered to be a heating-dominated climate, cooling demands dominate the net energy demand of an office building. Solar shading systems are vital to reduce the cooling demand of an office building. Introducing shading systems might contribute to higher heating demands as well as higher demands for artificial lighting but at the same time it might be necessary in order to reduce glare issues. Simulations of a number of shading strategies have been performed for south- and north-facing office cubicles with varying floor areas, window sizes and window parameters. Energy demands for heating, cooling, lighting and ventilation fans have been assessed. The simulations show that the choice of shading strategy can have an impact on the energy demand of the offices. Depending on strategy, the energy demand can either increase or decrease compared to an unshaded one- or two-person office cubicle. In addition, the shading systems can contribute toward a lowered thermal transmittance value (U-value) of the window by functioning as an additional layer in the glazing unit when closed. Potential improvements of U-values have been studied in combination with the shading system’s effect on solar heat gains and daylight levels. Experimental investigations of in-between the panes solar shading system effects on window U-values are currently being carried out at the Research Centre on Zero Emission Buildings (www.ZEB.no). It was found that automatically controlled shading systems can reduce the energy demands of south-facing, small office cubicles, but that they should not be installed without a thorough case-by-case investigation as increased energy demands were found if an improper shading strategy was chosen. Upgrading to four-pane glazing will, however, always have a beneficial impact on the energy demand compared to two- and three-pane glazing.

[1]  Laura Bellia,et al.  Daylight glare: a review of discomfort indexes , 2008 .

[2]  Vítor Leal,et al.  Influence of shading control patterns on the energy assessment of office spaces , 2012 .

[3]  Athanassios Tzempelikos A methodology for integrated daylighting and thermal analysis of buildings , 2005 .

[4]  Åke Blomsterberg,et al.  Energy saving potential and strategies for electric lighting in future North European, low energy office buildings: A literature review , 2011 .

[5]  Christoph F. Reinhart,et al.  Monitoring manual control of electric lighting and blinds , 2003 .

[6]  John Mardaljevic,et al.  Useful daylight illuminances: A replacement for daylight factors , 2006 .

[7]  Myoung Souk Yeo,et al.  Automated blind control to maximize the benefits of daylight in buildings , 2010 .

[8]  Martin Vraa Nielsen,et al.  Quantifying the potential of automated dynamic solar shading in office buildings through integrated simulations of energy and daylight , 2011 .

[9]  Christoph F. Reinhart,et al.  The daylit area – Correlating architectural student assessments with current and emerging daylight availability metrics , 2012 .

[10]  Geoffrey Van Moeseke,et al.  Impact of control rules on the efficiency of shading devices and free cooling for office buildings , 2007 .

[11]  Sarah Stevens,et al.  INTELLIGENT FACADES: OCCUPANT CONTROL AND SATISFACTION , 2001 .

[12]  Anca D. Galasiu,et al.  Occupant preferences and satisfaction with the luminous environment and control systems in daylit offices: a literature review , 2006 .

[13]  A. Athienitis,et al.  The impact of shading design and control on building cooling and lighting demand , 2007 .

[14]  P. Fanger Calculation of Thermal Comfort, Introduction of a Basic Comfort Equation , 1967 .

[15]  R. G. Hopkinson,et al.  Glare from daylighting in buildings. , 1972, Applied ergonomics.

[16]  Kari Thunshelle,et al.  Brukerundersøkelse om innemiljø på Marienlyst skole , 2012 .

[17]  Werner Osterhaus,et al.  Discomfort glare assessment and prevention for daylight applications in office environments , 2005 .

[18]  Kyung-Hee Lee,et al.  An Experimental Study for the Evaluation of the Environmental Performance by the Application of the Automated Venetian Blind , 2007 .

[19]  Svend Svendsen,et al.  An hourly-based performance comparison of an integrated micro-structural perforated shading screen with standard shading systems , 2012 .

[20]  Helena Bülow-Hübe,et al.  Energy-Efficient Window Systems - Effects on Energy Use and Daylight in Buildings , 2001 .

[21]  Matthias Haase,et al.  Optimizing the configuration of a façade module for office buildings by means of integrated thermal and lighting simulations in a total energy perspective , 2013 .