Resolving Ultrasound Contrast Microbubbles Using Minimum Variance Beamforming

Minimum Variance (MV) beamforming is known to improve the lateral resolution of ultrasound images and enhance the separation of isolated point scatterers. This paper aims to evaluate the adaptive beamformer’s performance with flowing microbubbles (MBs) which are relevant to super-resolution ultrasound imaging. Simulations using point scatterer data from single emissions were complemented by an experimental investigation performed using a capillary tube phantom and the Synthetic Aperture Real-time Ultrasound System (SARUS). The MV performance was assessed by the minimum distance that allows the display of two scatterers positioned side-by-side, the lateral Full-Width-at-Half-Maximum (FWHM), and the Peak-Sidelobe-Level (PSL). In the tube, scatterer responses separated by down to $196~\mu \text{m}$ (or $1.05\lambda $ ) were distinguished by the MV method, while the standard Delay-And-Sum (DAS) beamformers were unable to achieve such separation. Up to ninefold FWHM decrease was also measured in favor of the MV beamformer for individual echoes from MBs. The lateral distance between two scatterers impacted on their FWHM value, and additional differences in the scatterers’ axial or out-of-plane position also impacted on their size and appearance. The simulation and experimental results were in agreement in terms of lateral resolution. The point scatterer study showed that the proposed MV imaging scheme provided clear resolution benefits compared to DAS. Current super-resolution methods mainly depend on DAS beamformers. Instead, the use of the MV method may provide a larger number of detected, and potentially better localized, MB scatterers.

[1]  J.A. Jensen,et al.  Fast parametric beamformer for synthetic aperture imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  David G. Long,et al.  Array signal processing , 1985, IEEE Trans. Acoust. Speech Signal Process..

[3]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[4]  W. McDicken,et al.  An in vitro study of a microbubble contrast agent using a clinical ultrasound imaging system. , 2004, Physics in medicine and biology.

[5]  Sverre Holm,et al.  Capon beamforming and moving objects-an analysis of lateral shift-invariance , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[6]  W N McDicken,et al.  The behaviour of individual contrast agent microbubbles. , 2003, Ultrasound in medicine & biology.

[7]  J. Capon High-resolution frequency-wavenumber spectrum analysis , 1969 .

[8]  A. Austeng,et al.  Adaptive Beamforming Applied to Medical Ultrasound Imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  Sverre Holm,et al.  Implementing capon beamforming on a GPU for real-time cardiac ultrasound imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[10]  A. Austeng,et al.  Benefits of minimum-variance beamforming in medical ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Yong-Ping Zheng,et al.  Subarray coherence based postfilter for eigenspace based minimum variance beamformer in ultrasound plane-wave imaging. , 2016, Ultrasonics.

[12]  Sverre Holm,et al.  Eigenspace Based Minimum Variance Beamforming Applied to Ultrasound Imaging of Acoustically Hard Tissues , 2012, IEEE Transactions on Medical Imaging.

[13]  F. Gran,et al.  Broadband minimum variance beamforming for ultrasound imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Mickaël Tanter,et al.  Transcranial functional ultrasound imaging of the brain using microbubble-enhanced ultrasensitive Doppler , 2016, NeuroImage.

[15]  Richard W. Prager,et al.  Minimum Variance Approaches to Ultrasound Pixel-Based Beamforming , 2017, IEEE Transactions on Medical Imaging.

[16]  Robert J. Eckersley,et al.  In Vivo Acoustic Super-Resolution and Super-Resolved Velocity Mapping Using Microbubbles , 2015, IEEE Transactions on Medical Imaging.

[17]  Hirofumi Taki,et al.  High Range Resolution Ultrasonographic Vascular Imaging Using Frequency Domain Interferometry With the Capon Method , 2012, IEEE Transactions on Medical Imaging.

[18]  W. Marczak,et al.  Water as a standard in the measurements of speed of sound in liquids , 1997 .

[19]  A. Austeng,et al.  An approach to multibeam covariance matrices for adaptive beamforming in ultrasonography , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[21]  J.A. Jensen,et al.  Effects Influencing Focusing in Synthetic Aperture Vector Flow Imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  A. Klibanov,et al.  Detection of Individual Microbubbles of Ultrasound Contrast Agents: Imaging of Free-Floating and Targeted Bubbles , 2004, Investigative radiology.

[23]  F. Harris On the use of windows for harmonic analysis with the discrete Fourier transform , 1978, Proceedings of the IEEE.

[24]  Ole Marius Hoel Rindal,et al.  Hypothesis of Improved Visualization of Microstructures in the Interventricular Septum with Ultrasound and Adaptive Beamforming. , 2017, Ultrasound in medicine & biology.

[25]  Vassilis Sboros,et al.  Experimental performance assessment of the sub‐band minimum variance beamformer for ultrasound imaging , 2017, Ultrasonics.

[26]  S. I. Nikolov,et al.  SARUS: A synthetic aperture real-time ultrasound system , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[27]  K. Thomenius,et al.  Evolution of ultrasound beamformers , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.

[28]  Billy Y S Yiu,et al.  GPU-based minimum variance beamformer for synthetic aperture imaging of the eye. , 2015, Ultrasound in medicine & biology.

[29]  F. S. George,et al.  Diagnostic Ultrasound: Physics and Equipment, 2nd ed. , 2012 .

[30]  Georg Schmitz,et al.  Detection and Tracking of Multiple Microbubbles in Ultrasound B-Mode Images , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[31]  Simon Holbek,et al.  Safety Assessment of Advanced Imaging Sequences I: Measurements , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[32]  W.D. O'Brien,et al.  Synthetic aperture techniques with a virtual source element , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  Jørgen Arendt Jensen,et al.  A comparison between temporal and subband minimum variance adaptive beamforming , 2014, Medical Imaging.

[34]  Mickael Tanter,et al.  Ultrafast imaging in biomedical ultrasound , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[35]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[36]  Ryan M. Jones,et al.  Three-Dimensional Transcranial Ultrasound Imaging of Microbubble Clouds Using a Sparse Hemispherical Array , 2014, IEEE Transactions on Biomedical Engineering.

[37]  W N McDicken,et al.  An in vitro comparison of ultrasonic contrast agents in solutions with varying air levels. , 2000, Ultrasound in medicine & biology.

[38]  Avinash C. Kak,et al.  Array signal processing , 1985 .

[39]  Renbiao Wu,et al.  Time-delay- and time-reversal-based robust capon beamformers for ultrasound imaging , 2005, IEEE Transactions on Medical Imaging.

[40]  Francois Vignon,et al.  Capon beamforming in medical ultrasound imaging with focused beams , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[41]  A Mahloojifar,et al.  Contrast enhancement and robustness improvement of adaptive ultrasound imaging using forward-backward minimum variance beamforming , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.