A novel LVRT strategy for direct-drive wind turbines based on permanent magnet synchronous generator

Increasing penetration level of wind energy into the power system over the last decades has brought new issues and challenges. One of these concerns is the issue of low voltage ride through (LVRT). In this paper, given the characteristics of MW-level direct-drive wind turbines based on permanent magnet synchronous generator, a novel LVRT strategy is proposed, which is the combination of coordinate control of generator-side and grid-side converters and small un-loading branch. The implementation principle as well as calculation criteria are explained in depth. Finally, the feasibility of the proposed method is demonstrated by simulation results under balanced and unbalanced sag conditions.

[1]  T. Funabashi,et al.  Operation strategies for stability of gearless wind power generation systems , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[2]  Zhe Chen,et al.  Overview of different wind generator systems and their comparisons , 2008 .

[3]  Fei Zhou,et al.  A simple sensorless control of MW-level direct-drive permanent magnet wind generator , 2011, 2011 International Conference on Electrical Machines and Systems.

[4]  G. Joos,et al.  Supercapacitor Energy Storage for Wind Energy Applications , 2007, IEEE Transactions on Industry Applications.

[5]  Sheng-wen Liu,et al.  A Novel LVRT of Permanent Magnet Direct-Driven Wind Turbine , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[6]  C. Jauch Stability and control of wind farms in power systems , 2006 .

[7]  Ying Hua Han,et al.  Grid Integration of Wind Energy Conversion Systems , 2000 .

[8]  Hirofumi Akagi,et al.  Instantaneous power theory and applications to power conditioning , 2007 .

[9]  Stavros A. Papathanassiou,et al.  A review of grid code technical requirements for wind farms , 2009 .

[10]  Thomas Ackermann,et al.  Wind Power in Power Systems , 2005 .

[11]  Xuezhi Wu,et al.  Error analysis and limit value design of a simple sensorless control for MW-level DDWT-PMSG , 2012, Proceedings of The 7th International Power Electronics and Motion Control Conference.

[12]  G. Joos,et al.  Effect of low voltage ride through (LVRT) characteristic on voltage stability , 2005, IEEE Power Engineering Society General Meeting, 2005.

[13]  Anca Daniela Hansen,et al.  Multi-pole permanent magnet synchronous generator wind turbines' grid support capability in uninterrupted operation during grid faults , 2009 .

[14]  Dong-Choon Lee,et al.  Improvement of power quality for PMSG wind turbine systems , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[15]  J. F. Conroy,et al.  Low-voltage ride-through of a full converter wind turbine with permanent magnet generator , 2007 .

[16]  Jun Li,et al.  A novel power-flow balance LVRT control strategy for low-speed direct-drive PMSG wind generation system , 2010, IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society.

[17]  Angelo Baggini,et al.  Handbook of Power Quality , 2008 .