Control of wind-excited towers by active tuned liquid column damper

Abstract An active control system involving a tuned liquid column damper (TLCD) is developed for the vibration control of a single-degree-of-freedom tower subjected to wind excitation. This new control system will be referred to as the active tuned liquid column damper (ATLCD) system. It is found that the wind-induced response of the tower can be reduced substantially by the ATLCD system. The most efficient type of sensor is found to be the acceleration sensor when compared with displacement- and velocity-type sensors. To assess the effectiveness of such a control system, a comparison study is made between the ATLCD and the active–passive tuned mass damper (APTMD). In seeking the optimal control parameters for both systems, the norm of the root-mean-square of the system output under actual wind excitation, ‖ H ‖ rms , is adopted as the objective function instead of the commonly used ‖ H ‖ 2 (i.e., the norm of the system output under a unit white noise). The results show that the proposed ATLCD system is a good alternative to the APTMD system. Considering the potential advantages of the liquid column damper, the ATLCD system may be a better choice for vibration control of wind-induced towers.

[1]  Ahsan Kareem,et al.  Frequency Domain Optimal Control of Wind‐Excited Buildings , 1992 .

[2]  Yl L. Xu,et al.  Parametric study of active mass dampers for wind-excited tall buildings , 1996 .

[3]  Chien Ming Wang,et al.  Effectiveness of tuned liquid column dampers for vibration control of towers , 1995 .

[4]  Thambirajah Balendra,et al.  Optimal Damper Characteristics of ATMD for Buildings under wind Loads , 1999 .

[5]  T. Balendra Vibration of Buildings to Wind and Earthquake Loads , 1993 .

[6]  Jun Kanda,et al.  Proposed formulae for the power spectral densities of fluctuating lift and torque on rectangular 3-D cylinders , 1993 .

[7]  W. Iwan,et al.  Application of Statistical Linearization Techniques to Nonlinear Multidegree-of-Freedom Systems , 1972 .

[8]  Bijan Samali,et al.  Performance of tuned mass dampers under wind loads , 1995 .

[9]  Harvey J. Greenberg,et al.  Design and implementation of optimization software , 1977, Math. Program..

[10]  T. T. Soong,et al.  Acceleration Feedback Control of MDOF Structures , 1996 .

[11]  John Roorda,et al.  Tendon Control in Tall Structures , 1975 .

[12]  J. D. Holmes,et al.  Listing of installations , 1995 .

[13]  Thambirajah Balendra,et al.  Control on Dynamic Structural Response Using Active-Passive Composite-Tuned Mass Dampers , 1999 .

[14]  Yozo Fujino,et al.  Parametric studies on tuned liquid damper (TLD) using circular containers by free-oscillation experiments. , 1988 .

[15]  Bijan Samali,et al.  Control of wind-induced tall building vibration by tuned mass dampers , 1992 .

[16]  Stephen P. Boyd,et al.  Linear controller design: limits of performance , 1991 .

[17]  N. Yang,et al.  Composite mass dampers for vibration control of wind-excited towers , 1998 .