Performance and energy consumptions of split type air conditioning units for different arrangements of outdoor units in confined building shafts

Abstract Architectural constraints always recommend placing the outdoor units of split type air-conditioning (AC) systems in building shafts. This leads to high on-coil temperature, high electric consumption of and low performance of the units. In the present study, a CFD simulations of this problem are conducted for different installation arrangements of the outdoor units in two different situations of building shafts: the shaft is closed from the bottom by a basement slab, and the shaft is open from the bottom on the basement floor. The study aims to put installation guidelines for optimum arrangements of the outdoor units in building shafts. The results show that (i) the performance of the AC units dramatically getting bad when the building shaft is closed from the bottom, (ii) for open-bottom shaft, the performance of the units decreases as the installation floor level of the unit increases, (iii) for open-bottom shafts, it is preferable to install all outdoor units at one wall except for upper floors units where it preferred to be installed on two adjacent walls, (iv) for closed bottom shafts, it is not recommended to install outdoor units in lower levels of the shafts but can be installed at upper levels.

[1]  Weeratunge Malalasekera,et al.  An introduction to computational fluid dynamics - the finite volume method , 2007 .

[2]  Kwan-Soo Lee,et al.  Effects of stacked condensers in a high-rise apartment building , 2005 .

[3]  Hansjürg Leibundgut,et al.  Stuck in a stack—Temperature measurements of the microclimate around split type condensing units in a high rise building in Singapore , 2014 .

[4]  Francis W.H. Yik,et al.  Influence of a depth of a recessed space to flow due to air-conditioner heat rejection , 2002 .

[5]  Qiuwang Wang,et al.  Effect of building re-entrant shape on performance of air-cooled condensing units , 2000 .

[6]  Cezar O.R. Negrão,et al.  Thermoeconomic analysis and optimization of residential split-type air conditioners , 2013 .

[7]  Zhang Lin,et al.  Prediction of on-coil temperature of condensers installed at tall building re-entrant , 1999 .

[8]  Bin Xu,et al.  Prediction of temperature rise near condensing units in the confined space of a high-rise building , 2007 .

[9]  Xin Wang,et al.  Influence of Air-conditioning Outdoor Unit Arrangement Strategy on Energy Consumption , 2016 .

[10]  Zhang Lin,et al.  Effect of condensing unit layout at building re-entrant on split-type air-conditioner performance , 2002 .

[11]  Abdollah Avara,et al.  Optimum placement of condensing units of split-type air-conditioners by numerical simulation , 2008 .

[12]  Qiuwang Wang,et al.  Flow analysis of condenser cooling air delivery via building light well , 2001 .

[13]  R. Pletcher,et al.  Computational Fluid Mechanics and Heat Transfer. By D. A ANDERSON, J. C. TANNEHILL and R. H. PLETCHER. Hemisphere, 1984. 599 pp. $39.95. , 1986, Journal of Fluid Mechanics.

[14]  Zhang Lin,et al.  Placement of condensing units of split-type air-conditioners at low-rise residences , 2002 .