Pencil beam all-optical ultrasound imaging

A miniature, directional fibre-optic acoustic source is presented that employs geometrical focussing to generate a nearly-collimated acoustic pencil beam. When paired with a fibre-optic acoustic detector, an all-optical ultrasound probe with an outer diameter of 2.5 mm is obtained that acquires a pulse-echo image line at each probe position without the need for image reconstruction. B-mode images can be acquired by translating the probe and concatenating the image lines, and artefacts resulting from probe positioning uncertainty are shown to be significantly lower than those observed for conventional synthetic aperture scanning of a non-directional acoustic source. The high image quality obtained for excised vascular tissue suggests that the all-optical ultrasound probe is ideally suited for in vivo, interventional applications.

[1]  Gabor Fichtinger,et al.  Electromagnetic tracking in surgical and interventional environments: usability study , 2015, International Journal of Computer Assisted Radiology and Surgery.

[2]  M. O’Donnell,et al.  Characterization of a broadband all-optical ultrasound transducer-from optical and acoustical properties to imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  A. Desjardins,et al.  Adaptive Light Modulation for Improved Resolution and Efficiency in All-Optical Pulse-Echo Ultrasound , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[4]  S. Ashkenazi,et al.  An all-optical thin-film high-frequency ultrasound transducer , 2011, 2011 IEEE International Ultrasonics Symposium.

[5]  Paul C. Beard,et al.  Characteristics of optimized fibre-optic ultrasound receivers for minimally invasive photoacoustic detection , 2015, Photonics West - Biomedical Optics.

[6]  Adrien E. Desjardins,et al.  Carbon‐Nanotube–PDMS Composite Coatings on Optical Fibers for All‐Optical Ultrasound Imaging , 2016 .

[7]  C. Mosse,et al.  Laser-generated ultrasound with optical fibres using functionalised carbon nanotube composite coatings , 2014 .

[8]  Xiaozheng Zeng,et al.  Optimal simulations of ultrasonic fields produced by large thermal therapy arrays using the angular spectrum approach. , 2009, The Journal of the Acoustical Society of America.

[9]  Lihong Wang Photoacoustic tomography: Ultrasonically beating optical diffusion and diffraction , 2014, Photonics West - Biomedical Optics.

[10]  H Gomersall,et al.  Efficient implementation of spatially-varying 3-D ultrasound deconvolution , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Florian Kral,et al.  Comparison of optical and electromagnetic tracking for navigated lateral skull base surgery , 2013, The international journal of medical robotics + computer assisted surgery : MRCAS.

[12]  P. Harris,et al.  In situ fenestration in the aortic arch. , 2010, Journal of vascular surgery.

[13]  Nicolò Speciale,et al.  Fiber optic broadband ultrasonic probe for virtual biopsy: Technological solutions , 2009, 2009 IEEE International Ultrasonics Symposium.

[14]  Sheng-Wen Huang,et al.  An integrated optoacoustic transducer combining etalon and black PDMS structures , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Zhen Xu,et al.  Carbon-Nanotube Optoacoustic Lens for Focused Ultrasound Generation and High-Precision Targeted Therapy , 2012, Scientific Reports.

[16]  Martin D. Fox,et al.  Ultrasound image enhancement: A review , 2012, Biomed. Signal Process. Control..

[17]  Chi Hyung Seo,et al.  Forward-looking intracardiac imaging catheters using fully integrated CMUT arrays , 2010, 2010 IEEE International Ultrasonics Symposium.

[18]  Edward Z. Zhang,et al.  Fabry Perot polymer film fibre-optic hydrophones and arrays for ultrasound field characterisation , 2004 .

[19]  P. M. van den Berg,et al.  Seismic applications of acoustic reciprocity , 1993 .

[20]  Tai-Kyong Song,et al.  In vitro and in vivo real-time imaging with ultrasonic limited diffraction beams , 1993, IEEE Trans. Medical Imaging.

[21]  C. Mosse,et al.  Broadband miniature optical ultrasound probe for high resolution vascular tissue imaging. , 2015, Biomedical optics express.

[22]  M. O'Donnell,et al.  Synthetic aperture imaging for small scale systems , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  Shai Ashkenazi,et al.  Polyimide-etalon all-optical ultrasound transducer for high frequency applications , 2014, Photonics West - Biomedical Optics.

[24]  B. Snyder,et al.  A sensitive optical micro-machined ultrasound sensor (OMUS) based on a silicon photonic ring resonator on an acoustical membrane , 2015, Scientific Reports.

[25]  Jan Laufer,et al.  Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues. , 2008, Applied optics.

[26]  P. Beard Biomedical photoacoustic imaging , 2011, Interface Focus.

[27]  Pai-Chi Li,et al.  All-optical scanhead for ultrasound and photoacoustic imaging—Imaging mode switching by dichroic filtering☆ , 2014, Photoacoustics.