Transmural Atrial Insulating Lesions Using Epicardially Applied Radiofrequency Energy Coupled With Saline Irrigation

The Maze procedure has been demonstrated to eliminate atrial fibrillation (AF) refractory to medical management. The procedure, however, is technically difficult and requires prolonged cardiopulmonary bypass (CPB). We investigated the use of epicardially applied radiofrequency (RF) energy delivered using a saline-irrigated probe to functionally reproduce the linear lesions of the surgical Maze procedure. The goals of this study were to safely produce transmural atrial insulation lines without CPB and to investigate whether they could retain their electrical insulation properties and structural integrity over an acute time period. Baseline pacing thresholds were measured on the atria of six swine. Then, circular insulating lesions ( n = 11) were created around each pacing site using a saline-irrigated RF probe and specifically designed radiofrequency generator. Pacing thresholds were repeated at the same atrial sites, and in adjacent areas, immediately following lesion creation and at 7 days. At sacrifice the areas of interest were removed for histopathology. Pacing thresholds increased from 0.9 - 0.09 V to 9.59 - 0.87 V immediately following lesion formation ( p < .05) and remained supraphysiologic at 4.05 - 0.36 V after 7 days ( p < .05). Thresholds from outside the lesions were unchanged from baseline. There was no evidence of perforation and histologic analysis demonstrated transmural necrosis with advancing granulation tissue. Our data suggest that epicardially applied RF energy coupled with saline irrigation can produce transmural electrical insulation lines for up to 7 days. However, the decreasing trend in thresholds toward baseline suggests further investigation is needed to verify insulation line continuity over a chronic time period. These lines were created safely and efficiently without CPB, and may be applicable to a minimally invasive Maze procedure.

[1]  H. Wellens,et al.  Radiofrequency modified maze in patients with atrial fibrillation undergoing concomitant cardiac surgery. , 2001, The Journal of thoracic and cardiovascular surgery.

[2]  R Loire,et al.  Thoracoscopic Epicardial Radiofrequency Ablation for Vagal Atrial Fibrillation in Dogs , 1999, Pacing and clinical electrophysiology : PACE.

[3]  J L Cox,et al.  The closed heart MAZE: a nonbypass surgical technique. , 1999, The Annals of thoracic surgery.

[4]  J Melo,et al.  Surgery for atrial fibrillation using radiofrequency catheter ablation: assessment of results at one year. , 1999, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[5]  Toshihiko Ueda,et al.  Video Assisted Thoracoscopic and Cardioscopic Radiofrequency Maze Ablation , 1997, ASAIO journal.

[6]  J L Cox,et al.  Modification of the maze procedure for atrial flutter and atrial fibrillation. II. Surgical technique of the maze III procedure. , 1995, The Journal of thoracic and cardiovascular surgery.

[7]  L. Pires,et al.  Use of the Saline Infusion Electrode Catheter for Improved Energy Delivery and Increased Lesion Size in Radiofrequency Catheter Ablation , 1995, Pacing and clinical electrophysiology : PACE.

[8]  Y. Kawashima,et al.  Cox maze procedure for chronic atrial fibrillation associated with mitral valve disease. , 1994, The Journal of thoracic and cardiovascular surgery.

[9]  R. Bolman,et al.  The role of electrolyte in lesion size using an irrigated radiofrequency electrode. , 1997, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[10]  H. Kasanuki,et al.  Natural history of atrial fibrillation. , 1987, Heart and vessels. Supplement.