The effect of knot location, suture material, and suture size on the gliding resistance of flexor tendons.

The effect of knot location, suture material, and suture size on gliding resistance between the pulley and flexor tendon was investigated in a canine model. Different suture materials [monofilament nylon (Ethilon), braided polyester suture coated with silicone (Ticron) and uncoated braided polyester suture (Mersilene)] and suture sizes (4-0, 5-0) were tested. A knot was made on either the volar surface, on one lateral side, or on both lateral sides of canine hind-paw tendons, and gliding resistance was measured. In addition, the frictional coefficient between three suture materials (4-0 nylon, 4-0 Ticron, 4-0 Mersilene) and a nylon rod were measured. The gliding resistance of the tendon with knots on both sides was highest, while tendons with one lateral knot had the lowest resistance (p < 0.01). The gliding resistance of 4-0 suture size was higher than that of 5-0 size (p < 0.0001). The coefficient of friction of nylon was lower than that of braided polyester suture (Ticron or Mersilene) (p < 0.001). The placement of knots and choice of suture material affect gliding resistance after tendon repair, and may, therefore, have an effect on the result of tendon repair.

[1]  E. Ebramzadeh,et al.  Use of the Taguchi Method for Biomechanical Comparison of Flexor-Tendon-Repair Techniques to Allow Immediate Active Flexion. A New Method of Analysis and Optimization of Technique to Improve the Quality of the Repair*† , 1998, The Journal of bone and joint surgery. American volume.

[2]  R. Papandrea,et al.  Biomechanical and clinical evaluation of the epitenon-first technique of flexor tendon repair. , 1995, The Journal of hand surgery.

[3]  P C Amadio,et al.  Method for the measurement of friction between tendon and pulley , 1995, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[4]  L. Gottlieb,et al.  Mechanical comparison of 10 suture materials before and after in vivo incubation. , 1994, The Journal of surgical research.

[5]  S. Woo,et al.  In vitro biomechanical analysis of suture methods for flexor tendon repair , 1993, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[6]  H. Becker Primary Repair Of Flexor Tendons In The Hand Without Immobilisation – Preliminary Report , 1978, The Hand.

[7]  K. Tsuge,et al.  Repair of flexor tendons by intratendinous tendon suture. , 1977, The Journal of hand surgery.

[8]  P. Matthews,et al.  Factors in the adherence of flexor tendon after repair: an experimental study in the rabbit. , 1976, The Journal of bone and joint surgery. British volume.

[9]  N Mitchell,et al.  The resurfacing of adult rabbit articular cartilage by multiple perforations through the subchondral bone. , 1976, The Journal of bone and joint surgery. American volume.

[10]  H E Kleinert,et al.  Primary repair of flexor tendons. , 1973, The Orthopedic clinics of North America.

[11]  I. Kessler The “Grasping” Technique for Tendon Repair , 1973, The Hand.