Computer-enhanced stereoscopic vision in a head-mounted display for oral implant surgery.

We developed a head-mounted display (HMD) with integrated computer-generated stereoscopic projection of target structures and integrated it into visit, a specific oral implant planning and navigation software. The HMD is equipped with two miniature computer monitors that project computer-generated graphics stereoscopically into the optical path. Its position is tracked by the navigation system's optical tracker and target structures are displayed in their true position over the operation site. In order to test this system's accuracy and spatial perception of the viewer, five interforaminal implants in three dry human mandibles were planned with visit and executed using the stereoscopic projection through the HMD. The deviation between planned and achieved position of the implants was measured on corresponding computed tomography (CT) scan images recorded post-operatively. The deviation between planned and achieved implant position at the jaw crest was 0.57 +/- 0.49 mm measured from the lingual, and 0.58 +/- 0.4 mm measured from the buccal cortex. At the tip of the implants the deviation was 0.77 +/- 0.63 mm at the lingual and 0.79 +/- 0.71 mm at the buccal cortex. The mean angular deviation between planned and executed implant position was 3.55 +/- 2.07 degrees. The present in vitro experiment indicates that the concept of preoperative planning and transfer to the operative field by an HMD allows us to achieve an average precision within 1 mm (range up to 3 mm) of the implant position and within 3 degrees deviation for the implant inclination (range up to 10 degrees ). Control during the drilling procedure is significantly improved by stereoscopic vision through the HMD resulting in a more accurate inclination of the implants.

[1]  Torsten Rohlfing,et al.  Augmented-reality visualization of brain structures with stereo and kinetic depth cues: system description and initial evaluation with head phantom , 2001, SPIE Medical Imaging.

[2]  J. Strohbehn,et al.  A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope. , 1986, Journal of neurosurgery.

[3]  David J. Hawkes,et al.  Design and evaluation of a system for microscope-assisted guided interventions (MAGI) , 2000 .

[4]  A Wagner,et al.  Virtual image guided navigation in tumor surgery--technical innovation. , 1995, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[5]  H Bergmann,et al.  Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method. , 1999, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[6]  G H Barnett,et al.  Adaptation of personal projection television to a head-mounted display for intra-operative viewing of neuroimaging. , 1995, Journal of image guided surgery.

[7]  A M DiGioia,et al.  Augmented reality and its future in orthopaedics. , 1998, Clinical orthopaedics and related research.

[8]  Berthold K. P. Horn,et al.  Closed-form solution of absolute orientation using unit quaternions , 1987 .

[9]  H F Reinhardt,et al.  Interactive sonar-operated device for stereotactic and open surgery. , 1990, Stereotactic and functional neurosurgery.

[10]  Wolfgang Birkfellner,et al.  Calibration of projection parameters in the varioscope AR, a head-mounted display for augmented-reality visualization in image-guided therapy , 2001, SPIE Medical Imaging.

[11]  H Bergmann,et al.  Placement of Endosteal Implants in the Zygoma after Maxillectomy: A Cadaver Study Using Surgical Navigation , 2001, Plastic and reconstructive surgery.

[12]  J. Berger,et al.  Computer-vision-enabled augmented reality fundus biomicroscopy. , 1999, Ophthalmology.

[13]  R Kikinis,et al.  Video registration virtual reality for nonlinkage stereotactic surgery. , 1994, Stereotactic and functional neurosurgery.

[14]  R. P. Gaston,et al.  A System for Microscope-Assisted Guided Interventions , 2000, Stereotactic and Functional Neurosurgery.

[15]  M Naitoh,et al.  Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants? , 2000, Clinical oral implants research.

[16]  Roger Y. Tsai,et al.  A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses , 1987, IEEE J. Robotics Autom..

[17]  J. Mühling,et al.  Computer assisted oral and maxillofacial surgery--a review and an assessment of technology. , 2001, International journal of oral and maxillofacial surgery.

[18]  Franz Kainberger,et al.  Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible. , 2002, Clinical oral implants research.

[19]  A Wagner,et al.  Image-guided surgery. , 1996, International journal of oral and maxillofacial surgery.

[20]  P Suetens,et al.  Computer-assisted planning of oral implant surgery: a three-dimensional approach. , 1996, The International journal of oral & maxillofacial implants.

[21]  David J. Hawkes,et al.  Stereo Augmented Reality in the Surgical Microscope , 2000, Presence: Teleoperators & Virtual Environments.

[22]  Wolfgang Birkfellner,et al.  A modular software system for computer-aided surgery and its first application in oral implantology , 2000, IEEE Transactions on Medical Imaging.

[23]  Franz Kainberger,et al.  Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: assessment of accuracy. , 2003, Clinical oral implants research.

[24]  R Shahidi,et al.  Proposed simulation of volumetric image navigation using a surgical microscope. , 1995, Journal of image guided surgery.

[25]  H Bergmann,et al.  In-vitro assessment of a registration protocol for image guided implant dentistry. , 2001, Clinical oral implants research.