Enhanced determination of glucose by microchip electrophoresis with pulsed amperometric detection

Abstract The present report describes a new analysis strategy for microchip capillary electrophoresis with pulsed amperometric detection and its application to the determination of glucose. The addition of sodium dodecyl sulfate (SDS) to the mobile phase and detection reservoir stabilized flow rates and enhanced the detection signal for glucose. A higher pH (compared to the running buffer) was used at the waste reservoir in order to improve the detection performance while maintaining good separations. To our knowledge, this is the first report describing the use of post-column pH modification using microchip electrophoresis. Under optimum conditions, a linear relationship between the peak current and the concentration of glucose was found between 10 −2 –10 −5  M, with a limit-of-detection of 1.2 μM. In addition, the separation of glucosamine and glucose was performed at pH 7.1 while the detection was performed at pH 11 to demonstrate the ability to use post-column pH modification.

[1]  A. Ewing,et al.  Prototyping disposable electrophoresis microchips with electrochemical detection using rapid marker masking and laminar flow etching , 2002, Electrophoresis.

[2]  Carlos D. Garcia,et al.  BHA and TBHQ Quantification in Cosmetic Samples , 2000 .

[3]  William R. LaCourse,et al.  Pulsed Electrochemical Detection in High-Performance Liquid Chromatography , 1997 .

[4]  Nancy Allbritton,et al.  Surface modification of poly(dimethylsiloxane) microfluidic devices by ultraviolet polymer grafting. , 2002, Analytical chemistry.

[5]  Dennis C. Johnson,et al.  Pulsed amperometric detection of carbohydrates, amines and sulfur species in ion chromatography : the current state of research , 1993 .

[6]  Adam Eckhardt,et al.  Comparison of standard capillary and chip separations of sodium dodecylsulfate-protein complexes. , 2003, Journal of chromatography. A.

[7]  C. Hedley,et al.  Improved method for the analysis of alpha-galactosides in pea seeds by capillary zone electrophoresis. Comparison with high-performance liquid chromatography-triple-pulsed amperometric detection. , 1996, Journal of chromatography. A.

[8]  Susan M Lunte,et al.  Recent developments in amperometric detection for microchip capillary electrophoresis , 2002, Electrophoresis.

[9]  C. Henry,et al.  Pulsed amperometric detection of carbohydrates on an electrophoretic microchip. , 2002, The Analyst.

[10]  Joseph Wang,et al.  Portable electrochemical systems , 2002 .

[11]  Annelise E Barron,et al.  Microchannel wall coatings for protein separations by capillary and chip electrophoresis , 2003, Electrophoresis.

[12]  P. Ortiz Determination of tert‐Butylhydroxytoluene by Flow Injection Analysis at Polymer Modified Glassy Carbon Electrodes , 1998 .

[13]  William R. LaCourse,et al.  Detection of carbohydrates by capillary electrophoresis with pulsed amperometric detection , 1993 .

[14]  V. Dolnik,et al.  Capillary electrophoresis on microchip , 2000, Electrophoresis.

[15]  H. Nakanishi,et al.  Rapid analysis of amino sugars by microchip electrophoresis with laser‐induced fluorescence detection , 2001, Electrophoresis.

[16]  D. Erickson,et al.  Joule heating and heat transfer in poly(dimethylsiloxane) microfluidic systems. , 2003, Lab on a chip.

[17]  H. Becker,et al.  Polymer microfluidic devices. , 2002, Talanta.

[18]  Yuzhi Fang,et al.  Determination of sugars in Chinese traditional drugs by CE with amperometric detection. , 2002, Journal of pharmaceutical and biomedical analysis.

[19]  Frédéric Reymond,et al.  Polymer microfluidic chips for electrochemical and biochemical analyses , 2002, Electrophoresis.

[20]  B. Dräger,et al.  Pulsed amperometric detection of calystegines separated by capillary electrophoresis. , 2001, Journal of chromatography. A.

[21]  J. Landers,et al.  Exploiting sensitive laser-induced fluorescence detection on electrophoretic microchips for executing rapid clinical diagnostics. , 2001, Luminescence : the journal of biological and chemical luminescence.

[22]  A. Barron,et al.  Functional materials for microscale genomic and proteomic analyses. , 2002, Current opinion in biotechnology.

[23]  Yan Liu,et al.  Versatile 3-channel high-voltage power supply for microchip capillary electrophoresis. , 2003, Lab on a chip.

[24]  Wenzhe Lu,et al.  Pulsed amperometric detection of carbohydrates separated by capillary electrophoresis , 1993 .

[25]  N. Kaji,et al.  Characterization of electrophoretic behavior of sugar isomers by microchip electrophoresis coupled with videomicroscopy. , 2003, Analytical chemistry.

[26]  W. LaCourse,et al.  Pulsed amperometric detection of aliphatic alcohols in liquid chromatography , 1991 .

[27]  Lihua Zhang,et al.  Microchip electrophoresis-based separation of DNA. , 2003, Journal of pharmaceutical and biomedical analysis.

[28]  S. Lunte,et al.  Capillary electrophoresis with pulsed amperometric detection of carbohydrates and glycopeptides , 1996, Electrophoresis.

[29]  G. S. Owens,et al.  Pulsed electrochemical detection of nonchromophoric compounds following capillary electrophoresis , 1996, Electrophoresis.

[30]  Rosanne M Guijt,et al.  Use of bioaffinity interactions in electrokinetically controlled assays on microfabricated devices , 2002, Electrophoresis.

[31]  S. Terry,et al.  A gas chromatographic air analyzer fabricated on a silicon wafer , 1979, IEEE Transactions on Electron Devices.

[32]  Darwin R. Reyes,et al.  Micro total analysis systems. 2. Analytical standard operations and applications. , 2002, Analytical chemistry.

[33]  J. Landers,et al.  Evaluation of microchip electrophoresis as a molecular diagnostic method for Duchenne muscular dystrophy. , 2002, Clinical chemistry.

[34]  G. Whitesides,et al.  Components for integrated poly(dimethylsiloxane) microfluidic systems , 2002, Electrophoresis.

[35]  E. Wang,et al.  Determination of biogenic amines by capillary electrophoresis with pulsed amperometric detection. , 2003, Journal of chromatography. A.

[36]  M. Cretich,et al.  Separation of DNA fragments in hydroxylated poly(dimethylacrylamide) copolymers , 2002, Electrophoresis.

[37]  C. Henry,et al.  Experimental studies of electroosmotic flow dynamics in microfabricated devices during current monitoring experiments. , 2003, Analytical chemistry.

[38]  E. Verpoorte Microfluidic chips for clinical and forensic analysis , 2002, Electrophoresis.

[39]  B. Weigl,et al.  Lab-on-a-chip for drug development. , 2003, Advanced drug delivery reviews.

[40]  S. Lunte,et al.  Microchip capillary electrophoresis/ electrochemistry , 2001, Electrophoresis.

[41]  A. Taga,et al.  Analysis of carbohydrates as 1-phenyl-3-methyl-5-pyrazolone derivatives by capillary/microchip electrophoresis and capillary electrochromatography. , 2003, Journal of pharmaceutical and biomedical analysis.

[42]  A. Baranski,et al.  Experimental factors in pulsed electrochemical detection in capillary electrophoresis , 1998 .

[43]  H. Shiigi,et al.  Enantioselective uptake of amino acids using an electromodulated column packed with carbon fibres modified with overoxidised polypyrrole. , 2002, The Analyst.

[44]  C. Fujimoto Titanium dioxide coated surfaces for capillary electrophoresis and capillary electrochromatography , 2002, Electrophoresis.

[45]  Joseph Wang,et al.  Electrochemical detection for microscale analytical systems: a review. , 2002, Talanta.

[46]  D. J. Harrison,et al.  Electrokinetic control of fluid flow in native poly(dimethylsiloxane) capillary electrophoresis devices , 2000, Electrophoresis.

[47]  D. Westerlund,et al.  Capillary electrophoresis of glycoconjugates in alkaline media , 1993 .

[48]  Darwin R. Reyes,et al.  Micro total analysis systems. 1. Introduction, theory, and technology. , 2002, Analytical chemistry.

[49]  Frank Kohler,et al.  Poly(vinyl alcohol)‐coated microfluidic devices for high‐performance microchip electrophoresis , 2002, Electrophoresis.

[50]  G. S. Owens,et al.  Pulsed electrochemical detection of thiols and disulfides following capillary electrophoresis. , 1997, Journal of chromatography. B, Biomedical sciences and applications.

[51]  Carlos D. Garcia,et al.  Electrochemical characterization of glassy carbon electrodes modified by resol mixtures , 2001 .

[52]  Hossein Salimi-Moosavi,et al.  Protein separation and surfactant control of electroosmotic flow in poly(dimethylsiloxane)-coated capillaries and microchips. , 2002, Journal of chromatography. A.

[53]  C. Henry,et al.  Dynamic coating using polyelectrolyte multilayers for chemical control of electroosmotic flow in capillary electrophoresis microchips. , 2000, Analytical chemistry.

[54]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[55]  Elisabeth Verpoorte,et al.  Application of surface biopassivated disposable poly(dimethylsiloxane)/glass chips to a heterogeneous competitive human serum immunoglobulin G immunoassay with incorporated internal standard , 2002, Electrophoresis.

[56]  Dennis C. Johnson,et al.  Amperometric detection of simple carbohydrates at platinum electrodes in alkaline solutions by application of a triple-pulse potential waveform , 1981 .