A signal filtering method for improved quantification and noise discrimination in fourier transform ion cyclotron resonance mass spectrometry-based metabolomics data

Direct-infusion electrospray-ionization Fourier transform ion cyclotron resonance mass spectrometry (DI ESI FT-ICR MS) is increasingly being utilized in metabolomics, including the high sensitivity selected ion monitoring (SIM)-stitching approach. Accurate signal quantification and the discrimination of real signals from noise remain major challenges for this approach, with both adversely affected by factors including ion suppression during electrospray, ion—ion interactions in the detector cell, and thermally-induced white noise. This is particularly problematic for complex mixture analysis where hundreds of metabolites are present near the noise level. Here we address relative signal quantification and noise discrimination issues in SIM-stitched DI ESI FT-ICR MS-based metabolomics. Using liver tissue, we first optimized the number of scans (n) acquired per SIM window to address the balance between quantification accuracy versus acquisition time (and thus sample throughput); a minimum of n = 5 is recommended. Secondly, we characterized and computationally-corrected an effect whereby an ion’s intensity is dependent upon its location within a SIM window, exhibiting a 3-fold higher intensity at the high m/z end. This resulted in significantly improved quantification accuracy. Finally, we thoroughly characterized a three-stage filter to discriminate noise from real signals, which comprised a signal-to-noise-ratio (SNR) hard threshold, then a “replicate” filter (retaining only peaks in r-out-of-3 replicate analyses), and then a “sample” filter (retaining only peaks in >s% of biological samples). We document the benefits of three-stage filtering versus one- and two-stage filters, and show the importance of selecting filter parameters that balance the confidence that a signal is real versus the total number of peaks detected.

[1]  John L Markley,et al.  Method for determining molar concentrations of metabolites in complex solutions from two-dimensional 1H-13C NMR spectra. , 2007, Analytical chemistry.

[2]  Peter B. O’Connor,et al.  Algorithms for automatic interpretation of high resolution mass spectra , 2006, Journal of the American Society for Mass Spectrometry.

[3]  M. Senko,et al.  Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions , 1995, Journal of the American Society for Mass Spectrometry.

[4]  L. Sweetlove,et al.  Application of metabolite profiling to the identification of traits in a population of tomato introgression lines. , 2004, Journal of experimental botany.

[5]  R. Breitling,et al.  Precision mapping of the metabolome. , 2006, Trends in biotechnology.

[6]  Matej Oresic,et al.  Processing methods for differential analysis of LC/MS profile data , 2005, BMC Bioinformatics.

[7]  Donald G Robertson,et al.  Metabonomics in toxicology: a review. , 2005, Toxicological sciences : an official journal of the Society of Toxicology.

[8]  A. Marshall Theoretical signal-to-noise ratio and mass resolution in Fourier transform ion cyclotron resonance mass spectrometry , 1979 .

[9]  Theodoros N. Arvanitis,et al.  Dynamic range and mass accuracy of wide-scan direct infusion nanoelectrospray fourier transform ion cyclotron resonance mass spectrometry-based metabolomics increased by the spectral stitching method. , 2007, Analytical chemistry.

[10]  Mark R Viant,et al.  International NMR-based environmental metabolomics intercomparison exercise. , 2009, Environmental science & technology.

[11]  Nigel W. Hardy,et al.  Hierarchical metabolomics demonstrates substantial compositional similarity between genetically modified and conventional potato crops. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[12]  M. Walsh,et al.  Metabolomics in human nutrition: opportunities and challenges. , 2005, The American journal of clinical nutrition.

[13]  T. Rejtar,et al.  A universal denoising and peak picking algorithm for LC-MS based on matched filtration in the chromatographic time domain. , 2003, Analytical chemistry.

[14]  I. Rusyn,et al.  Towards high-throughput metabolomics using ultrahigh-field Fourier transform ion cyclotron resonance mass spectrometry , 2008, Metabolomics.

[15]  D. Muddiman,et al.  Understanding the influence of post-excite radius and axial confinement on quantitative proteomic measurements using Fourier transform ion cyclotron resonance mass spectrometry. , 2007, Rapid communications in mass spectrometry : RCM.

[16]  Lothar Willmitzer,et al.  High-resolution direct infusion-based mass spectrometry in combination with whole 13C metabolome isotope labeling allows unambiguous assignment of chemical sum formulas. , 2008, Analytical chemistry.

[17]  R. M. A. Heeren,et al.  Parallel processing of large datasets from NanoLC-FTICR-MS measurements , 2007, Journal of the American Society for Mass Spectrometry.

[18]  J. Haselden,et al.  Use of liquid chromatography/time-of-flight mass spectrometry and multivariate statistical analysis shows promise for the detection of drug metabolites in biological fluids. , 2003, Rapid communications in mass spectrometry : RCM.

[19]  Theodoros N. Arvanitis,et al.  A new approach to toxicity testing in Daphnia magna: application of high throughput FT-ICR mass spectrometry metabolomics , 2009, Metabolomics.

[20]  W. Dunn,et al.  Evaluation of automated electrospray-TOF mass spectrometryfor metabolic fingerprinting of the plant metabolome , 2005, Metabolomics.

[21]  David I. Ellis,et al.  Metabolomics: Current analytical platforms and methodologies , 2005 .

[22]  Mark R Viant,et al.  NMR-based metabolomics: a powerful approach for characterizing the effects of environmental stressors on organism health. , 2003, Environmental science & technology.

[23]  S. Kanaya,et al.  Clarification of Pathway-Specific Inhibition by Fourier Transform Ion Cyclotron Resonance/Mass Spectrometry-Based Metabolic Phenotyping Studies1[W] , 2006, Plant Physiology.

[24]  R. Abagyan,et al.  XCMS: processing mass spectrometry data for metabolite profiling using nonlinear peak alignment, matching, and identification. , 2006, Analytical chemistry.

[25]  D. Muddiman,et al.  Impact of ion cloud densities on the measurement of relative ion abundances in Fourier transform ion cyclotron resonance mass spectrometry: experimental observations of coulombically induced cyclotron radius perturbations and ion cloud dephasing rates. , 2001, Journal of mass spectrometry : JMS.

[26]  Lyle Burton,et al.  Investigation of analytical variation in metabonomic analysis using liquid chromatography/mass spectrometry. , 2007, Rapid communications in mass spectrometry : RCM.

[27]  G. Uechi,et al.  Space charge effects on relative peak heights in fourier transform-ion cyclotron resonance spectra , 1992, Journal of the American Society for Mass Spectrometry.

[28]  B. van Ravenzwaay,et al.  The use of metabolomics for the discovery of new biomarkers of effect. , 2007, Toxicology letters.

[29]  C. Enke,et al.  Practical implications of some recent studies in electrospray ionization fundamentals. , 2001, Mass spectrometry reviews.

[30]  D. Muddiman,et al.  Quantification of singly charged biomolecules by electrospray ionization fourier transform ion cyclotron resonance mass spectrometry utilizing an internal standard , 1999 .

[31]  Richard D. Smith,et al.  Mass measurement errors caused by “local” frequency perturbations in FTICR mass spectrometry , 2002, Journal of the American Society for Mass Spectrometry.

[32]  J. Zumberge,et al.  Detailed compositional comparison of acidic NSO compounds in biodegraded reservoir and surface crude oils by negative ion electrospray Fourier transform ion cyclotron resonance mass spectrometry , 2007 .

[33]  G. Kruppa,et al.  Metabolomics applications of FT-ICR mass spectrometry. , 2005, Mass spectrometry reviews.

[34]  A. Marshall,et al.  Fourier transform ion cyclotron resonance mass spectrometry: a primer. , 1998, Mass spectrometry reviews.

[35]  Mark R Viant,et al.  Spectral relative standard deviation: a practical benchmark in metabolomics. , 2009, The Analyst.

[36]  H. Cooper,et al.  Liver tumors in wild flatfish: a histopathological, proteomic, and metabolomic study. , 2005, Omics : a journal of integrative biology.

[37]  M. Viant,et al.  High-throughput tissue extraction protocol for NMR- and MS-based metabolomics. , 2008, Analytical biochemistry.

[38]  A. Smilde,et al.  Large-scale human metabolomics studies: a strategy for data (pre-) processing and validation. , 2006, Analytical chemistry.