Use of Ultra-High-Performance Concrete for Bridge Deck Overlays

The most common bridge deterioration begins with cracking in the deck followed by water and chloride infiltration into the concrete core and corrosion damage to the reinforcement of the deck. Further damage to bridge deck occurs due to freeze-thaw cycles, exposure to deicing salts, and dynamic loads from vehicular traffic and plow trucks. Cracking on bridge decks is common, and bridge deck deterioration is a leading cause of structurally obsolete or deficient inspection ratings.

[1]  Kazutaka Shirai,et al.  Experimental investigation on the behaviour of reinforced concrete slabs strengthened with ultra-high performance concrete , 2017 .

[2]  Kenneth F. Dunker,et al.  WHY AMERICA'S BRIDGES ARE CRUMBLING , 1993 .

[3]  F. Moreno,et al.  Warm mix asphalt: an overview , 2012 .

[4]  S. Billington,et al.  Bond behavior and interface modeling of reinforced high-performance fiber-reinforced cementitious composites , 2017 .

[5]  Glenn Washer,et al.  Guidelines for Thermographic Inspection of Concrete Bridge Components in Shaded Conditions , 2013 .

[6]  Brent M. Phares,et al.  Evaluation of Air-Coupled Impact-Echo Test Method , 2015 .

[7]  Moncef L. Nehdi,et al.  Infrared thermography model for automated detection of delamination in RC bridge decks , 2018 .

[8]  Eugen Brühwiler,et al.  Experimental Investigation on Reinforced Ultra-High-Performance Fiber-Reinforced Concrete Composite Beams Subjected to Combined Bending and Shear by Talayeh Noshiravani and , 2013 .

[9]  Mohit Verma,et al.  Theoretical modelling and acoustic emission monitoring of RC beams strengthened with UHPC , 2018 .

[10]  Devin K. Harris,et al.  Combined Imaging Technologies for Concrete Bridge Deck Condition Assessment , 2015 .

[11]  K Babaei,et al.  EVALUATION OF BRIDGE DECK PROTECTIVE STRATEGIES , 1987 .

[13]  Shuhei Hiasa,et al.  Effect of Defect Size on Subsurface Defect Detectability and Defect Depth Estimation for Concrete Structures by Infrared Thermography , 2017 .

[14]  Glenn Washer,et al.  Effects of Environmental Variables on Infrared Imaging of Subsurface Features of Concrete Bridges , 2009 .

[15]  Investigation of a Suitable Shear Friction Interface between UHPC and Normal Strength Concrete for Bridge Deck Applications , 2017 .

[16]  Eugen Brühwiler,et al.  Rehabilitation and Strengthening of Concrete Structures Using Ultra-High Performance Fibre Reinforced Concrete , 2013 .

[17]  Nenad Gucunski,et al.  Comprehensive Bridge Deck Deterioration Mapping of Nine Bridges by Nondestructive Evaluation Technologies , 2011 .

[18]  Sri Sritharan,et al.  Design and Performance Verification of Ultra-High Performance Concrete Piles for Deep Foundations , 2008 .

[19]  Eugen Brühwiler,et al.  Cast-on site UHPFRC for improvement of existing structures - achievements over the last 10 years in practice and research , 2015 .

[20]  Koji Mitani,et al.  A Review of Field Implementation of Infrared Thermography as a Non-destructive Evaluation Technology , 2014 .

[21]  S. Sritharan,et al.  First Application of UHPC Bridge Deck Overlay in North America , 2018 .

[22]  Philip D Cady,et al.  Deterioration Rates of Concrete Bridge Decks , 1984 .

[23]  C Birnstiel,et al.  CAUSES OF BRIDGE DETERIORATION , 1993 .

[24]  Halit Yazici,et al.  Flexural strengthening of RC beams using UHPFRC laminates: Bonding techniques and rebar addition , 2017 .

[25]  Robert E. Skinner,et al.  Nondestructive Testing to Identify Concrete Bridge Deck Deterioration , 2009 .

[26]  Z. Haber,et al.  Field Testing of an Ultra-High Performance Concrete Overlay , 2017 .

[27]  Ikhlas Abdel-Qader,et al.  Detection of Common Defects in Concrete Bridge Decks Using Nondestructive Evaluation Techniques , 2007 .

[28]  D. Harris,et al.  Characterization of Interface Bond of Ultra-High-Performance Concrete Bridge Deck Overlays , 2011 .

[29]  Ikhlas Abdel-Qader,et al.  Segmentation of thermal images for non-destructive evaluation of bridge decks , 2008 .

[30]  John S. Popovics,et al.  NDE techniques for concrete and masonry structures , 2003 .

[31]  Yuan Yuan,et al.  Fatigue Life Assessment of Orthotropic Steel Deck with UHPC Pavement , 2017 .

[32]  Sri Sritharan Design of UHPC Structural Members: Lessons Learned and ASTM Test Requirements , 2015 .

[33]  Dar-Hao Chen,et al.  Design improvements to enhance the performance of thin and ultra-thin concrete overlays in Texas , 2016 .

[34]  Ralf W. Arndt,et al.  Comparison of NDT Methods for Assessment of a Concrete Bridge Deck , 2013 .

[35]  Elton Bauer,et al.  Infrared thermography – evaluation of the results reproducibility , 2015 .

[36]  David Darwin,et al.  Evaluation of Corrosion Protection Methods for Reinforced Concrete Highway Structures , 2000 .

[37]  Glenn Washer,et al.  A pixel-by-pixel reliability analysis of infrared thermography (IRT) for the detection of subsurface delamination , 2016 .

[38]  Eugen Brühwiler,et al.  Strengthening the Chillon viaducts deck slabs with reinforced UHPFRC , 2015 .

[39]  Michael Forde,et al.  Application of infrared thermography to the non-destructive testing of concrete and masonry bridges , 2003 .

[40]  Koji Mitani,et al.  Non-destructive Bridge Deck Assessment Using Image Processing and Infrared Thermography , 2014 .

[41]  Sri Sritharan,et al.  INNOVATIVE UHPC-NORMAL CONCRETE COMPOSITE BRIDGE DECK , 2013 .

[42]  Deon Kruger,et al.  Infrared thermography as a diagnostic tool for subsurface assessments of concrete structures , 2014 .

[43]  S. Tuli,et al.  Defect detection in concrete structures using thermal imaging techniques , 2011 .

[44]  Benjamin A. Graybeal,et al.  A comparison of nondestructive evaluation methods for bridge deck assessment , 2003 .

[45]  Chih-Hung Chiang,et al.  Defect detection of concrete structures using both infrared thermography and elastic waves , 2008 .