On-line flow injection monitoring of ammonia in industrial liquid effluents

Abstract A flow-injection method was applied to on-line analysis for ammonia in industrial liquid effluents. The method utilised the diffusion of gaseous ammonia from an alkaline sample stream, through a microporous membrane, into a bromothymol blue indicator stream, with the resulting colour change measured photometrically using a red LED. Following initial development work, the method was adapted to an automated, portable system, which was capable of linear response in the range 1–100 mg 1 −1 NH 3 -N. The portable flow injection monitor was powered by an external 12 V battery, and performed two-point self-calibration during each analytical cycle. The monitor was capable of unattended, continuous on-line monitoring of effluent streams at two industrial sites over several days. The results obtained were in good agreement with those produced by an indophenol blue laboratory reference method.

[1]  Paul J. Worsfold,et al.  Comparison of multivariate calibration techniques for the quantification of model process streams using diode-array spectrophotometry , 1994 .

[2]  Á. Ríos,et al.  Determination of pH, conductivity, residual chlorine and ammonium and nitrite lons in water with an unsegmented flow configuration , 1988 .

[3]  M. D. L. Castro,et al.  Simultaneous determination of ammonia and urea with an asymmetric merging zones/flow-injection configuration , 1989 .

[4]  Purnendu K. Dasgupta,et al.  Fluorometric measurement of aqueous ammonium ion in a flow injection system , 1989 .

[5]  J. Miller,et al.  Statistics for Analytical Chemistry , 1993 .

[6]  S. R. Crouch,et al.  Investigation of a Chemiluminescent System for the Determination of Ammonia by Flow-Injection Analysis , 1987 .

[7]  K. Johnson,et al.  A rapid, highly sensitive technique for the determination of ammonia in seawater , 1986 .

[8]  R. Schothorst,et al.  Determination of total ammoniacal introgen in water by flow injection analysis and a gas diffusion membrane , 1983 .

[9]  J. Bartrolí,et al.  Flow injection system for on-line potentiometric monitoring of ammonia in freshwater streams , 1989 .

[10]  M. Gisin,et al.  Industrial process control by flow injection analysis , 1986 .

[11]  Jaromír Růžička,et al.  Flow injection analysis — a survey of its potential for continuous monitoring of industrial processes , 1986 .

[12]  W. Woolcock Chemistry and industry , 1924 .

[13]  M. D. Castro,et al.  Continuous monitoring by unsegmented flow techniques State of the art and perspectives. , 1989 .

[14]  C. Pasquini,et al.  Differential conductimetry in flow injection. Determination of ammonia in Kjeldahl digests , 1991 .

[15]  Mark E. Meyerhoff,et al.  Flow Injection Determination of Ammonia-N Using Polymer Membrane Electrode-based Gas Sensing System , 1981 .

[16]  T. Anfält,et al.  Rapid determination of ammonia in whole blood and plasma using flow injection analysis. , 1982, Clinica chimica acta; international journal of clinical chemistry.