Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer.

BACKGROUND AND PURPOSE The goal of this work is to develop and evaluate strategies to reduce the uncertainty in the prostate position and rectum shape that arises in the preparation stage of the radiation treatment of prostate cancer. PATIENTS AND METHODS Nineteen prostate cancer patients, who were treated with 3-dimensional conformal radiotherapy, received each a planning CT scan and 8-13 repeat CT scans during the treatment period. We quantified prostate motion relative to the pelvic bone by first matching the repeat CT scans on the planning CT scan using the bony anatomy. Subsequently, each contoured prostate, including seminal vesicles, was matched on the prostate in the planning CT scan to obtain the translations and rotations. The variation in prostate position was determined in terms of the systematic, random and group mean error. We tested the performance of two correction strategies to reduce the systematic error due to prostate motion. The first strategy, the pre-treatment strategy, used only the initial rectum volume in the planning CT scan to adjust the angle of the prostate with respect to the left-right (LR) axis and the shape and position of the rectum. The second strategy, the adaptive strategy, used the data of repeat CT scans to improve the estimate of the prostate position and rectum shape during the treatment. RESULTS The largest component of prostate motion was a rotation around the LR axis. The systematic error (1 SD) was 5.1 degrees and the random error was 3.6 degrees (1 SD). The average LR-axis rotation between the planning and the repeat CT scans correlated significantly with the rectum volume in the planning CT scan (r=0.86, P<0.0001). Correction of the rotational position on the basis of the planning rectum volume alone reduced the systematic error by 28%. A correction, based on the data of the planning CT scan and 4 repeat CT scans reduced the systematic error over the complete treatment period by a factor of 2. When the correction was carried out later in the treatment (based on the data of more scans) the overall reduction was less. For the rectum, the first strategy performed best at the upper anterior side, where a reduction of the anterior-posterior displacement of 30% could be achieved. The systematic error could be reduced by 43% for the whole rectum by using the data of 4 repeat CT scans and the planning CT scan. CONCLUSIONS Both the pre-treatment as well as the adaptive correction strategy reduced the systematic error in the prostate position and rectum position and shape. A smaller systematic error makes it possible to safely reduce the margin around the clinical tumor volume, so that normal tissues can be spared or the prescription dose can be escalated.

[1]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[2]  Michael J. Zelefsky,et al.  High-dose intensity modulated radiation therapy for prostate cancer: early toxicity and biochemical outcome in 772 patients. , 2002, International journal of radiation oncology, biology, physics.

[3]  P Kijewski,et al.  Analysis of prostate and seminal vesicle motion: implications for treatment planning. , 1996, International journal of radiation oncology, biology, physics.

[4]  M van Herk,et al.  Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. , 1995, International journal of radiation oncology, biology, physics.

[5]  Joos V Lebesque,et al.  Inclusion of geometric uncertainties in treatment plan evaluation. , 2002, International journal of radiation oncology, biology, physics.

[6]  B. Efron How Biased is the Apparent Error Rate of a Prediction Rule , 1986 .

[7]  M. Hoogeman,et al.  Impact of volume and location of irradiated rectum wall on rectal blood loss after radiotherapy of prostate cancer. , 2004, International journal of radiation oncology, biology, physics.

[8]  D Yan,et al.  An off-line strategy for constructing a patient-specific planning target volume in adaptive treatment process for prostate cancer. , 2000, International journal of radiation oncology, biology, physics.

[9]  D. Dearnaley,et al.  Comparison of radiation side-effects of conformal and conventional radiotherapy in prostate cancer: a randomised trial , 1999, The Lancet.

[10]  M. V. van Herk,et al.  Quantification of local rectal wall displacements by virtual rectum unfolding. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  G J Kutcher,et al.  Variation in prostate position quantitation and implications for three-dimensional conformal treatment planning. , 1997, International journal of radiation oncology, biology, physics.

[12]  Steve B. Jiang,et al.  When should systematic patient positioning errors in radiotherapy be corrected? , 2002, Physics in medicine and biology.

[13]  J A Antolak,et al.  Prostate target volume variations during a course of radiotherapy. , 1998, International journal of radiation oncology, biology, physics.

[14]  R. Zellars,et al.  Prostate position late in the course of external beam therapy: patterns and predictors. , 2000, International journal of radiation oncology, biology, physics.

[15]  J C Stroom,et al.  Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability. , 1999, International journal of radiation oncology, biology, physics.

[16]  Harry Keller,et al.  Optimal stochastic correction strategies for rigid-body target motion. , 2003, International journal of radiation oncology, biology, physics.

[17]  B. Heijmen,et al.  A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload. , 2001, International journal of radiation oncology, biology, physics.

[18]  A. Lomax,et al.  Influence of rectal volume changes during radiotherapy for prostate cancer: a predictive model for mild-to-moderate late rectal toxicity. , 2003, International journal of radiation oncology, biology, physics.

[19]  C. Pelizzari,et al.  Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy. , 1995, International journal of radiation oncology, biology, physics.

[20]  J C Stroom,et al.  Internal organ motion in prostate cancer patients treated in prone and supine treatment position. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[21]  H. Kooy,et al.  Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching. , 1994, Medical physics.

[22]  M Goitein,et al.  Late rectal bleeding following combined X-ray and proton high dose irradiation for patients with stages T3-T4 prostate carcinoma. , 1993, International journal of radiation oncology, biology, physics.

[23]  D. Yan,et al.  Adaptive radiation therapy , 1997, Physics in medicine and biology.

[24]  David A Jaffray,et al.  Automatic localization of the prostate for on-line or off-line image-guided radiotherapy. , 2004, International journal of radiation oncology, biology, physics.

[25]  Marcel van Herk,et al.  Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[26]  F Nüsslin,et al.  Adapting inverse planning to patient and organ geometrical variation: algorithm and implementation. , 2003, Medical physics.

[27]  M S Hoogeman,et al.  Dose-wall histograms and normalized dose-surface histograms for the rectum: a new method to analyze the dose distribution over the rectum in conformal radiotherapy. , 1999, International journal of radiation oncology, biology, physics.