Desktop guidance for mitigating Pb and Cu corrosion by‐products

Utility experiences were examined to assess the reliability of solubility models and decision trees in forecasting control of lead (Pb) and copper (Cu) corrosion by-products. Such approaches cannot quantitatively predict effectiveness of corrosion control. For example, even the best-fit solubility models explain only about 35 and 18% of the quantitative variation in 90th percentile Cu and Pb release, respectively. However, the decision trees and solubility models are qualitatively consistent with utility experience and are thus useful when promising water quality changes are identified to mitigate corrosion byproduct release. Utility experiences confirm that an optimal alkalinity range exists for Pb corrosion control above pH 8.5, a higher mass ratio of chloride to sulfate tends to worsen Pb by-product release, and detectable color can signal a natural organic material content that may adversely affect compliance with the Cu action limit.

[1]  D. Lytle,et al.  Using aeration for corrosion control , 1998 .

[2]  Marc Edwards,et al.  Copper Corrosion in Potable Water Systems: Impacts of Natural Organic Matter and Water Treatment Processes , 1996 .

[3]  R. Gregory Galvanic Corrosion of Lead Solder in Copper Pipework , 1990 .

[4]  Michael R. Schock,et al.  Understanding Corrosion Control Strategies for Lead , 1989 .

[5]  Michael Schock,et al.  Plumbosolvency reduction by high pH and low carbonate- solubility relationships , 1983 .

[6]  Thomas R. Holm,et al.  Potential Effects of Polyphosphate Products on Lead Solubility in Plumbing Systems , 1991 .

[7]  John F. Ferguson,et al.  The pitting corrosion of copper , 1994 .

[8]  P. J. Jackson,et al.  Scientific basis for control of lead in drinking water by water treatment , 1981 .

[9]  Marc Edwards,et al.  Corrosion control on the basis of utility experience , 1995 .

[10]  MICHAEL R. SCHOCK,et al.  Causes of temporal variability of lead in domestic plumbing systems , 1990, Environmental monitoring and assessment.

[11]  John F. Ferguson,et al.  Influence of NOM on copper corrosion , 1996 .

[12]  Michael R. Schock,et al.  Modeling issues of copper solubility in drinking water , 1994 .

[13]  J. Ferguson,et al.  Accelerated Testing of Copper Corrosion , 1993 .

[14]  Michael R. Schock,et al.  Effect of pH, DIC, Orthophosphate and Sulfate on Drinking Water Cuprosolvency , 1996 .

[15]  Michael R. Schock,et al.  Alkalinity, pH, and copper corrosion by‐product release , 1996 .