Abstract Saturated DC reactor type superconducting fault current limiter (SFCL) had been proposed two years ago. It was classified to rectifier type SFCL. The changing inductance value with the operating mode has superior characteristics to reduce voltage sag during step increase of the load current. But it has the disadvantage of its weight. In this paper, rectifier type SFCL with shielded reactor has been proposed. The reactor which has superconducting ring or tube inside its winding is substituted to the DC link of the rectifier. The configuration looks like an air core transformer with secondary short winding. When the current through the bulk shield-ring reaches to a certain level, the flux penetrates to the shield body and finite impedance appears in the primary winding. In other words, when the surface flux density exceeds its critical flux density, the flux penetrates into the bulk superconductor, and increases equivalent inductance. The equivalent transient resistance of the shield was represented as a function of exponential of the time. Using this equivalent transient resistance, the transient impedance was expressed. The transient wave analysis using EMTDC (electro-magnetic transients in DC systems) has been described. Simulated waveforms are shown considering the source inductance, the leakage inductance, the coupling coefficient and the forward voltage drop of the semiconductor. And voltage sag was also investigated with 50% step load increase. Preliminary design was also performed. The coil size and number of turns are designed to obtain adequate inductance for the current limitation, and the central magnetic field of the coils are calculated. There is optimal aspect ratio to minimize the magnetic field with restriction in outer diameter of the coil.
[1]
Khosru M. Salim,et al.
Preliminary experiments on saturated DC reactor type fault current limiter
,
2002
.
[2]
K. M. Salim,et al.
DC reactor effect on bridge type superconducting fault current limiter during load increasing
,
2001
.
[3]
Khosru M. Salim,et al.
Proposal of saturated DC reactor type superconducting fault current limiter (SFCL)
,
2001
.
[4]
B. Raju,et al.
A Current Limiting Device Using Superconducting D.C. Bias Applications and Prospects
,
1982,
IEEE Transactions on Power Apparatus and Systems.
[5]
A. Shikov,et al.
Model of HTS three-phase saturated core fault current limiter
,
2000,
IEEE Transactions on Applied Superconductivity.
[6]
H. Boenig,et al.
Fault current limiter using a superconducting coil
,
1982
.
[7]
Toshiaki Ueda,et al.
Solid-state current limiter for power distribution system
,
1993
.
[8]
Usable Ranges of Some Expressions for Calculation of the Self-Inductance of a Circular Coil of Rectangular Cross Section
,
1995
.