The maintenance of the second-order advantage: second-order calibration of excitation-emission matrix fluorescence for quantitative analysis of herbicide napropamide in various environmental samples.
暂无分享,去创建一个
Hai-Long Wu | Ru-Qin Yu | Yong-Jie Yu | Xiang-Dong Qing | Chong-Chong Nie | Shu-Rong Zhang | R. Yu | Hai-Long Wu | Shu-Rong Zhang | Yong-Jie Yu | Shu-Fang Li | Yuan-Na Li | Xiangdong Qing | Yuan-Na Li | Shu-Fang Li | Chong-Chong Nie
[1] Ronei J. Poppi,et al. Second- and third-order multivariate calibration: data, algorithms and applications , 2007 .
[2] B. Kowalski,et al. Theory of analytical chemistry , 1994 .
[3] R. Tauler. Multivariate curve resolution applied to second order data , 1995 .
[4] Yun Zhang,et al. Determination of testosterone propionate in cosmetics using excitation-emission matrix fluorescence based on oxidation derivatization with the aid of second-order calibration methods , 2008 .
[5] Avraham Lorber,et al. Net analyte signal calculation in multivariate calibration , 1997 .
[6] R. Bro,et al. Multi‐way prediction in the presence of uncalibrated interferents , 2007 .
[7] R. Yu,et al. Quantitative analysis of hydrolysis of carbaryl in tap water and river by excitation-emission matrix fluorescence coupled with second-order calibration. , 2008, Talanta.
[8] M. C. Ortiz,et al. The maintenance of a PARAFAC calibration and the second-order property: application to the determination of ciprofloxacin in presence of enrofloxacin by excitation–emission fluorescence , 2005 .
[9] J. Chang,et al. Analysis of individual differences in multidimensional scaling via an n-way generalization of “Eckart-Young” decomposition , 1970 .
[10] R. Bro,et al. A new efficient method for determining the number of components in PARAFAC models , 2003 .
[11] Alejandro C Olivieri,et al. Computing sensitivity and selectivity in parallel factor analysis and related multiway techniques: the need for further developments in net analyte signal theory. , 2005, Analytical chemistry.
[12] R. Yu,et al. Interference-free determination of and in plant samples using excitation-emission matrix fluorescence based on oxidationderivatization coupled with second-order calibration methods. , 2009, Analytical methods : advancing methods and applications.
[13] M. A. Herrador,et al. Intra-laboratory testing of method accuracy from recovery assays. , 1999, Talanta.
[14] Hai-Long Wu,et al. An alternating trilinear decomposition algorithm with application to calibration of HPLC–DAD for simultaneous determination of overlapped chlorinated aromatic hydrocarbons , 1998 .
[15] R. Yu,et al. Interference-free determination of Sudan dyes in chilli foods using second-order calibration algorithms coupled with HPLC-DAD. , 2007, Talanta.
[16] Yang Li,et al. A novel trilinear decomposition algorithm for second-order linear calibration , 2000 .
[17] A. Lorber. Error propagation and figures of merit for quantification by solving matrix equations , 1986 .
[18] Bruce R. Kowalski,et al. Generalized rank annihilation factor analysis , 1986 .
[19] M. P. Callao,et al. Analytical applications of second-order calibration methods. , 2008, Analytica chimica acta.
[20] Hong Yang,et al. Salicylic Acid Reduces Napropamide Toxicity by Preventing Its Accumulation in Rapeseed (Brassica napus L.) , 2010, Archives of environmental contamination and toxicology.
[21] Hai-Long Wu,et al. Alternating penalty trilinear decomposition algorithm for second‐order calibration with application to interference‐free analysis of excitation–emission matrix fluorescence data , 2005 .
[22] Alejandro C Olivieri,et al. Analytical advantages of multivariate data processing. One, two, three, infinity? , 2008, Analytical chemistry.
[23] L. F. Bermejo,et al. Determination of napropamide in technical formulations, soil and vegetable samples by sensitised fluorescence: validation of the method , 2003 .
[24] A. Olivieri,et al. A closed‐form expression for computing the sensitivity in second‐order bilinear calibration , 2005 .
[25] J. Braga,et al. Determination of pesticides and metabolites in wine by high performance liquid chromatography and second-order calibration methods. , 2007, Journal of chromatography. A.
[26] Hai-Long Wu,et al. Quantitative analysis of triazine herbicides in environmental samples by using high performance liquid chromatography and diode array detection combined with second-order calibration based on an alternating penalty trilinear decomposition algorithm. , 2010, Analytica chimica acta.
[27] P. Biswas,et al. Persistence of Napropamide in/on Tea under North-East Indian Climatic Condition , 2007, Bulletin of environmental contamination and toxicology.
[28] G. M. Escandar,et al. Two different strategies for the fluorimetric determination of piroxicam in serum. , 2003, Talanta.
[29] Alejandro C. Olivieri,et al. Standard error of prediction in parallel factor analysis of three-way data , 2004 .
[30] G. M. Escandar,et al. Spectrofluorimetry in organized media coupled to second-order multivariate calibration for the determination of galantamine in the presence of uncalibrated interferences. , 2010, Talanta.
[31] A. Afkhami,et al. Second-order advantage applied to simultaneous spectrofluorimetric determination of paracetamol and mefenamic acid in urine samples. , 2009, Analytica chimica acta.
[32] Alejandro C Olivieri,et al. Interference-free analysis using three-way fluorescence data and the parallel factor model. Determination of fluoroquinolone antibiotics in human serum. , 2003, Analytical chemistry.