The maintenance of the second-order advantage: second-order calibration of excitation-emission matrix fluorescence for quantitative analysis of herbicide napropamide in various environmental samples.

A rapid non-separative spectrofluorometric method based on the second-order calibration of excitation-emission matrix (EEM) fluorescence was proposed for the determination of napropamide (NAP) in soil, river sediment, and wastewater as well as river water samples. With 0.10 mol L(-1) sodium citrate-hydrochloric acid (HCl) buffer solution of pH 2.2, the system of NAP has a large increase in fluorescence intensity. To handle the intrinsic fluorescence interferences of environmental samples, the alternating penalty trilinear decomposition (APTLD) algorithm as an efficient second-order calibration method was employed. Satisfactory results have been achieved for NAP in complex environmental samples. The limit of detection obtained for NAP in soil, river sediment, wastewater and river water samples were 0.80, 0.24, 0.12, 0.071 ng mL(-1), respectively. Furthermore, in order to fully investigate the performance of second-order calibration method, we test the second-order calibration method using different calibration approaches including the single matrix model, the intra-day various matrices model and the global model based on the APTLD algorithm with nature environmental datasets. The results showed the second-order calibration methods also enable one or more analyte(s) of interest to be determined simultaneously in the samples with various types of matrices. The maintenance of second-order advantage has been demonstrated in simultaneous determinations of the analyte of interests in the environmental samples of various matrices.

[1]  Ronei J. Poppi,et al.  Second- and third-order multivariate calibration: data, algorithms and applications , 2007 .

[2]  B. Kowalski,et al.  Theory of analytical chemistry , 1994 .

[3]  R. Tauler Multivariate curve resolution applied to second order data , 1995 .

[4]  Yun Zhang,et al.  Determination of testosterone propionate in cosmetics using excitation-emission matrix fluorescence based on oxidation derivatization with the aid of second-order calibration methods , 2008 .

[5]  Avraham Lorber,et al.  Net analyte signal calculation in multivariate calibration , 1997 .

[6]  R. Bro,et al.  Multi‐way prediction in the presence of uncalibrated interferents , 2007 .

[7]  R. Yu,et al.  Quantitative analysis of hydrolysis of carbaryl in tap water and river by excitation-emission matrix fluorescence coupled with second-order calibration. , 2008, Talanta.

[8]  M. C. Ortiz,et al.  The maintenance of a PARAFAC calibration and the second-order property: application to the determination of ciprofloxacin in presence of enrofloxacin by excitation–emission fluorescence , 2005 .

[9]  J. Chang,et al.  Analysis of individual differences in multidimensional scaling via an n-way generalization of “Eckart-Young” decomposition , 1970 .

[10]  R. Bro,et al.  A new efficient method for determining the number of components in PARAFAC models , 2003 .

[11]  Alejandro C Olivieri,et al.  Computing sensitivity and selectivity in parallel factor analysis and related multiway techniques: the need for further developments in net analyte signal theory. , 2005, Analytical chemistry.

[12]  R. Yu,et al.  Interference-free determination of and in plant samples using excitation-emission matrix fluorescence based on oxidationderivatization coupled with second-order calibration methods. , 2009, Analytical methods : advancing methods and applications.

[13]  M. A. Herrador,et al.  Intra-laboratory testing of method accuracy from recovery assays. , 1999, Talanta.

[14]  Hai-Long Wu,et al.  An alternating trilinear decomposition algorithm with application to calibration of HPLC–DAD for simultaneous determination of overlapped chlorinated aromatic hydrocarbons , 1998 .

[15]  R. Yu,et al.  Interference-free determination of Sudan dyes in chilli foods using second-order calibration algorithms coupled with HPLC-DAD. , 2007, Talanta.

[16]  Yang Li,et al.  A novel trilinear decomposition algorithm for second-order linear calibration , 2000 .

[17]  A. Lorber Error propagation and figures of merit for quantification by solving matrix equations , 1986 .

[18]  Bruce R. Kowalski,et al.  Generalized rank annihilation factor analysis , 1986 .

[19]  M. P. Callao,et al.  Analytical applications of second-order calibration methods. , 2008, Analytica chimica acta.

[20]  Hong Yang,et al.  Salicylic Acid Reduces Napropamide Toxicity by Preventing Its Accumulation in Rapeseed (Brassica napus L.) , 2010, Archives of environmental contamination and toxicology.

[21]  Hai-Long Wu,et al.  Alternating penalty trilinear decomposition algorithm for second‐order calibration with application to interference‐free analysis of excitation–emission matrix fluorescence data , 2005 .

[22]  Alejandro C Olivieri,et al.  Analytical advantages of multivariate data processing. One, two, three, infinity? , 2008, Analytical chemistry.

[23]  L. F. Bermejo,et al.  Determination of napropamide in technical formulations, soil and vegetable samples by sensitised fluorescence: validation of the method , 2003 .

[24]  A. Olivieri,et al.  A closed‐form expression for computing the sensitivity in second‐order bilinear calibration , 2005 .

[25]  J. Braga,et al.  Determination of pesticides and metabolites in wine by high performance liquid chromatography and second-order calibration methods. , 2007, Journal of chromatography. A.

[26]  Hai-Long Wu,et al.  Quantitative analysis of triazine herbicides in environmental samples by using high performance liquid chromatography and diode array detection combined with second-order calibration based on an alternating penalty trilinear decomposition algorithm. , 2010, Analytica chimica acta.

[27]  P. Biswas,et al.  Persistence of Napropamide in/on Tea under North-East Indian Climatic Condition , 2007, Bulletin of environmental contamination and toxicology.

[28]  G. M. Escandar,et al.  Two different strategies for the fluorimetric determination of piroxicam in serum. , 2003, Talanta.

[29]  Alejandro C. Olivieri,et al.  Standard error of prediction in parallel factor analysis of three-way data , 2004 .

[30]  G. M. Escandar,et al.  Spectrofluorimetry in organized media coupled to second-order multivariate calibration for the determination of galantamine in the presence of uncalibrated interferences. , 2010, Talanta.

[31]  A. Afkhami,et al.  Second-order advantage applied to simultaneous spectrofluorimetric determination of paracetamol and mefenamic acid in urine samples. , 2009, Analytica chimica acta.

[32]  Alejandro C Olivieri,et al.  Interference-free analysis using three-way fluorescence data and the parallel factor model. Determination of fluoroquinolone antibiotics in human serum. , 2003, Analytical chemistry.