The use of Schottky CdTe detectors for high-energy astronomy: application to the detection plane of the instrument SVOM/ECLAIRs

Ohmic CdZnTe and CdTe detectors have been successfully used in high-energy missions such as IBIS on-board INTEGRAL and the Swift-BAT in the past two decades. Such detectors provide very good quantum efficiency in the hard X-ray band. For the future generation of hard X-ray coded mask detectors, a higher sensitivity will be required. A way to achieve this is to increase the effective area of the pixilated detection plane, to change the mask pattern and/or the properties of the semi-conductors paving the detection plane. For the future Chinese-French Gamma-ray burst mission SVOM, the GRB trigger camera ECLAIRs will make use of a new type of high-energy detectors, the Schottky CdTe detectors. Such detectors, when reversely biased, are known to present very low leakage current, resulting in lower values of the low-energy threshold (down to 4 keV or less) than for previous missions (i.e. > 10 keV for the Swift-BAT and INTEGRAL/IBIS). Such low values will enable ECLAIRs with a moderate geometrical area of 1024 cm2 and a low-energy threshold of 4 keV to be more sensitive to high-redshift GRBs (emitting mainly in X-rays) than the Swift-BAT with a higher effective area and low-energy threshold. However, the spectral performance of such detectors are known to degrade over time, once polarized, due to the polarization effect that strongly depends on the temperature and the bias voltage applied to the detectors. In this paper, we present an intensive study of the properties of Schottky CdTe detectors as used on SVOM/ECLAIRs such as I-V characteristics, polarization effect, activation energy and low temperature annealing effects. We discuss the implications of these measurements on the use of this type of detectors in future high-energy instruments.

[1]  Kazuyuki Satoh,et al.  Growth and characterization of CdTe single crystals for radiation detectors , 1999 .

[2]  E. Delagnes,et al.  IDeF-X ECLAIRs: A CMOS ASIC for the Readout of CdTe and CdZnTe Detectors for High Resolution Spectroscopy , 2009, IEEE Transactions on Nuclear Science.

[3]  V. A. Gnatyuk,et al.  High Energy Resolution CdTe Schottky Diode $\gamma$-Ray Detectors , 2012, IEEE Transactions on Nuclear Science.

[4]  Didier Barret,et al.  Extensive testing of Schottky CdTe detectors for the ECLAIRs X-/gamma-ray camera on board the SVOM mission , 2010 .

[5]  Goro Sato,et al.  The Burst Alert Telescope (BAT) on the SWIFT Midex Mission , 2004 .

[6]  J. P. Osborne,et al.  The Chinese-French SVOM Mission: studying the brightest astronomical explosions , 2012, Other Conferences.

[7]  Victor Ivanov,et al.  Advances in high-resolution CdTe and large-volume CdZnTe detectors , 1997, Optics & Photonics.

[8]  Kentaro Uesugi,et al.  Imaging and spectral performance of CdTe double-sided strip detectors for the hard x-ray imager onboard ASTRO-H , 2012, Other Conferences.

[9]  Tadayui Takahashi,et al.  Recent progress in CdTe and CdZnTe detectors , 2001, astro-ph/0107398.

[10]  Kazuyuki Hirose,et al.  High-resolution Schottky CdTe diode for hard X-ray and gamma-ray astronomy , 1999 .

[11]  P. Laurent,et al.  A CdTe gamma-camera for the space observatory INTEGRAL: software charge-loss corrections , 1996 .

[12]  F. Klotz,et al.  Annealing effects on defect levels of CdTe:Cl materials and the uniformity of the electrical properties , 2003 .

[13]  Olivier Limousin,et al.  The basic component of the ISGRI CdTe γ-ray camera for space telescope IBIS on board the INTEGRAL satellite , 1999 .

[14]  M. Livio,et al.  Nucleosynthesis, neutrino bursts and γ-rays from coalescing neutron stars , 1989, Nature.

[15]  Adriano Cola,et al.  The polarization mechanism in CdTe Schottky detectors , 2009 .

[16]  W. Marty,et al.  Development of a 32-detector CdTe matrix for the SVOM ECLAIRs X/Gamma camera: Preliminary results , 2013 .

[17]  Remoue Nadege,et al.  Extensive testing of Schottky CdTe detectors for the ECLAIRs X-Gamma-ray Camera on board the SVOM mission , 2010 .

[18]  G. Sato,et al.  Improvement of the CdTe diode detectors using a guard-ring electrode , 2004, IEEE Transactions on Nuclear Science.

[19]  Jang Ho Ha,et al.  Effect of Thermal Annealing on the Metal-Semiconductor Contact of a CZT Schottky Detector , 2009 .

[20]  Akira Higa,et al.  Quantitative Analysis of Polarization Phenomena in CdTe Radiation Detectors , 2006 .