Feasibility of telemetric ICP-guided valve adjustments for complex shunt therapy

ObjectThe advances in shunt valve technology towards modern adjustable differential pressure (DP) valves and adjustable gravitational assisted valves result in an increasing complexity of therapeutical options. Modern telemetric intracranial pressure (ICP) sensors may be helpful in their application for diagnostic purposes in shunt therapy. We present our first experiences on telemetric ICP-guided valve adjustments in cases with the combination of an adjustable DP valve and adjustable gravitational unit.MethodsFour consecutive cases were evaluated in a retrospective review who had received a proGAV adjustable, gravitational assisted DP valve with secondary in-line implantation of an adjustable shunt assistant (proSA), together with a telemetric ICP sensor (Neurovent-P-tel) between December 2010 and June 2012 in our institution. The measured ICP values and the corresponding valve adjustments were analyzed in correlation with the clinical course and the cranial imaging of the patients.ResultsNo surgery-related complications were observed after implantation of the proSA and the telemetric ICP sensor additional to the proGAV. ICP values could actively be influenced by adjustments of the respective valve units. An increase of the position depending resistance of the proSA resulted in significant attenuated negative ICP values for the standing position, while adjustments of the proGAV could be detected not only in a supine position but also in a standing position. A clinical improvement could be achieved in all cases.ConclusionThe combination of adjustability in the differential pressure valve and the gravitational unit reveals a complex combination which may be difficult to adapt only according to clinical information. Telemetric ICP-guided valve adjustments seem to be a promising tool as an objective measure according to different body positions. Further investigations are needed to select the patients for these costly implants.

[1]  J. Drake,et al.  Frontal and Occipital Horn Ratio: A Linear Estimate of Ventricular Size for Multiple Imaging Modalities in Pediatric Hydrocephalus , 1998, Pediatric Neurosurgery.

[2]  Y. Kajimoto,et al.  Posture-related changes in the pressure environment of the ventriculoperitoneal shunt system. , 2000, Journal of neurosurgery.

[3]  Xiao Hu,et al.  Relationship between Valve Opening Pressure, Body Position, and Intracranial Pressure in Normal Pressure Hydrocephalus: Paradigm for Selection of Programmable Valve Pressure Setting , 2004, Neurosurgery.

[4]  David M Allin,et al.  In vitro hydrodynamic properties of the Miethke proGAV hydrocephalus shunt , 2006, Cerebrospinal Fluid Research.

[5]  P. Virolainen,et al.  Repair of full-thickness rotator cuff tears is recommended regardless of tear size and age: a retrospective study of 218 patients. , 2007, Journal of shoulder and elbow surgery.

[6]  Chad M. Miller,et al.  SURGICAL MANAGEMENT OF ADULT HYDROCEPHALUS. , 2008, Neurosurgery.

[7]  Chad M. Miller,et al.  Surgical management of adult hydrocephalus. , 2008, Neurosurgery.

[8]  B. Romner,et al.  ADJUSTABLE VALVES IN NORMAL‐PRESSURE HYDROCEPHALUS: A RETROSPECTIVE STUDY OF 218 PATIENTS , 2002, Neurosurgery.

[9]  P. Eide,et al.  Changes in intracranial pulse pressure amplitudes after shunt implantation and adjustment of shunt valve opening pressure in normal pressure hydrocephalus , 2008, Acta Neurochirurgica.

[10]  J. Gilsbach,et al.  Management of hydrocephalus in infants by using shunts with adjustable valves. , 2008, Journal of neurosurgery. Pediatrics.

[11]  V. Rohde,et al.  First experiences with an adjustable gravitational valve in childhood hydrocephalus. , 2009, Journal of neurosurgery. Pediatrics.

[12]  J. Krauss,et al.  The Adjustable proGAV Shunt: A Prospective Safety and Reliability Multicenter Study , 2010, Neurosurgery.

[13]  U. Meier,et al.  Improved outcome in shunted iNPH with a combination of a Codman Hakim programmable valve and an Aesculap-Miethke ShuntAssistant. , 2010, Central European neurosurgery.

[14]  Inga Krause,et al.  Long-term performance of a CE-approved telemetric intracranial pressure monitoring , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  N. Kitchen,et al.  Use of the proGAV Shunt Valve in Normal-Pressure Hydrocephalus , 2011, Neurosurgery.

[16]  C. Sprung,et al.  Shunting with gravitational valves--can adjustments end the era of revisions for overdrainage-related events?: clinical article. , 2012, Journal of neurosurgery.

[17]  O. Sakowitz,et al.  Intracranial pressure telemetry: first experience of an experimental in vivo study using a new device. , 2012, Acta neurochirurgica. Supplement.

[18]  Steffen Leonhardt,et al.  Telemetric ICP measurement with the first CE-approved device: data from animal experiments and initial clinical experiences. , 2012, Acta neurochirurgica. Supplement.

[19]  Stefan Welschehold,et al.  First Clinical Results With a New Telemetric Intracranial Pressure-Monitoring System , 2012, Neurosurgery.

[20]  J. Pickard,et al.  Programmable Shunt Assistant tested in Cambridge shunt evaluation laboratory. , 2012, Acta neurochirurgica. Supplement.

[21]  H. Haberl,et al.  Shunt survival rates by using the adjustable differential pressure valve combined with a gravitational unit (proGAV) in pediatric neurosurgery , 2013, Child's Nervous System.

[22]  V. Rohde,et al.  Safety and efficacy of gravitational shunt valves in patients with idiopathic normal pressure hydrocephalus: a pragmatic, randomised, open label, multicentre trial (SVASONA) , 2013, Journal of Neurology, Neurosurgery & Psychiatry.

[23]  H. Haberl,et al.  Adjustments in gravitational valves for the treatment of childhood hydrocephalus—a retrospective survey , 2013, Child's Nervous System.

[24]  J. Drake,et al.  Outcomes of CSF shunting in children: comparison of Hydrocephalus Clinical Research Network cohort with historical controls: clinical article. , 2013, Journal of neurosurgery. Pediatrics.

[25]  P. Vajkoczy,et al.  Patients benefit from low-pressure settings enabled by gravitational valves in normal pressure hydrocephalus , 2013, Clinical Neurology and Neurosurgery.