Laser-assisted flat-detector CT-guided intracranial access
暂无分享,去创建一个
Laligam N. Sekhar | Louis J. Kim | Daniel L. Cooke | Michael R. Levitt | Danial K. Hallam | Basavaraj V. Ghodke | L. Sekhar | D. Cooke | L. Kim | M. Levitt | D. Hallam | B. Ghodke
[1] D. Babic,et al. Brain imaging with a flat detector C-arm , 2008, Neuroradiology.
[2] Gernot Kronreif,et al. A robotic needle-positioning and guidance system for CT-guided puncture: Ex vivo results , 2014, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.
[3] B. Son,et al. Comparison of frame-based and frameless stereotactic hematoma puncture and subsequent fibrinolytic therapy for the treatment of supratentorial deep seated spontaneous intracerebral hemorrhage. , 2007, Minimally invasive neurosurgery : MIN.
[4] Drazenko Babic,et al. Live 3D guidance in the interventional radiology suite. , 2007, AJR. American journal of roentgenology.
[5] O. Ganslandt,et al. Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT , 2008, Neuroradiology.
[6] Mechanical Accuracy of a New Stereotactic Guide , 2000, Acta Neurochirurgica.
[7] W. Eisner,et al. Accuracy and Clinical Use of a Novel Aiming Device for Frameless Stereotactic Brain Biopsy , 2008, Minimally invasive neurosurgery : MIN.
[8] D. Cooke,et al. Intraorbital access using fluoroscopic flat panel detector CT navigation and three-dimensional MRI overlay , 2010, Journal of NeuroInterventional Surgery.
[9] K. Moe,et al. The "triple-overlay" technique for percutaneous diagnosis and treatment of lesions of the head and neck: combined three-dimensional guidance with magnetic resonance imaging, cone-beam computed tomography, and fluoroscopy. , 2013, World neurosurgery.
[10] T. Brommeland,et al. A New Procedure for Frameless Computer Navigated Stereotaxy , 2000, Acta Neurochirurgica.
[11] T. Yoshizumi,et al. Evaluation of patient effective dose of neurovascular imaging protocols for C-arm cone-beam CT. , 2014, AJR. American journal of roentgenology.
[12] S. Mukherji,et al. Conebeam CT of the Head and Neck, Part 1: Physical Principles , 2009, American Journal of Neuroradiology.
[13] A. Berenstein,et al. The utility of DynaCT in neuroendovascular procedures. , 2006, AJNR. American journal of neuroradiology.
[14] L. Bour,et al. Postoperative Curving and Upward Displacement of Deep Brain Stimulation Electrodes Caused by Brain Shift , 2010, Neurosurgery.
[15] Daniel Ruijters,et al. First clinical experience in applying XperGuide in embolization of jugular paragangliomas by direct intratumoral puncture , 2009, International Journal of Computer Assisted Radiology and Surgery.
[16] Abhilash Pandya,et al. The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.
[17] Bernhard Meyer,et al. VARIOGUIDE: A NEW FRAMELESS IMAGE‐GUIDED STEREOTACTIC SYSTEM—ACCURACY STUDY AND CLINICAL ASSESSMENT , 2009, Neurosurgery.
[18] Alfredo Quiñones-Hinojosa,et al. Assessment of Image Guided Accuracy in a Skull Model: Comparison of Frameless Stereotaxy Techniques vs. Frame-Based Localization , 2005, Journal of Neuro-Oncology.
[19] G. Nesbit,et al. Integrated cone-beam CT and fluoroscopic navigation in treatment of head and neck vascular malformations and tumors , 2010, Journal of NeuroInterventional Surgery.
[20] N. Dorward,et al. Clinical Validation of True Frameless Stereotactic Biopsy: Analysis of the First 125 Consecutive Cases , 2001, Neurosurgery.
[21] Marcus Pfister,et al. C-Arm Cone Beam Computed Tomography Needle Path Overlay for Fluoroscopic Guided Vertebroplasty , 2010, Spine.
[22] Brian Nett,et al. A Simple Technique for Interventional Tool Placement Combining Fluoroscopy With Interventional Computed Tomography on a C‐Arm System , 2010, Neurosurgery.
[23] R. Nievelstein,et al. Effective dose during needle interventions: cone-beam CT guidance compared with conventional CT guidance. , 2011, Journal of vascular and interventional radiology : JVIR.
[24] M. Viergever,et al. Clinical evaluation of stereotactic brain biopsies with an MKM-mounted instrument holder , 2003, Acta Neurochirurgica.
[25] Z. Yang,et al. Treatment of Supratentorial Spontaneous Intracerebral Hemorrhage Using Image-Guided Minimally Invasive Surgery: Initial Experiences of a Flat Detector CT–Based Puncture Planning and Navigation System in the Angiographic Suite , 2014, American Journal of Neuroradiology.
[26] G. Widmann,et al. Target registration and target positioning errors in computer‐assisted neurosurgery: proposal for a standardized reporting of error assessment , 2009, The international journal of medical robotics + computer assisted surgery : MRCAS.
[27] F. Verdun,et al. Comparison of organ doses and image quality between CT and flat panel XperCT scans in wrist and inner ear examinations. , 2010, Radiation protection dosimetry.
[28] D. Cooke,et al. Transcranial Access Using Fluoroscopic Flat Panel Detector CT Navigation , 2011, American Journal of Neuroradiology.
[29] J H Siewerdsen,et al. Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype. , 2006, Medical physics.