Light-emitting diode-fluorescent microscopy: Determining its sensitivity and specificity in diagnosis of pulmonary tuberculosis in a high-burden tuberculosis region and resource-limited country like India

Background: Tuberculosis (TB) remains a major global health problem. India accounts for the one-fourth of the global TB burden. For resource-limited countries like India having high burden of TB, smear microscopy is the most commonly used method for microbiological diagnosis. Although culture being highly sensitive and specific method, it is time-consuming. Under Revised National TB Control Program (RNTCP), Ziehl–Neelsen (ZN) stain-based microscopy and light-emitting diode-based fluorescent microscopy (LED-FM) are being recommended. Aim: The present study was done to determine the sensitivity and specificity of ZN stain-based microscopy and FM (LED-FM) keeping solid culture as gold standard. Materials and Methods: A total of 1503 sputum samples were collected from suspected cases of pulmonary TB (new or previously treated). They were processed and subjected to ZN (conventional light microscopy), Auramine-O (AO) staining (LED-FM) and solid culture on Lowenstein–Jensen medium for detection of acid-fast bacilli. Positive smears were graded according to RNTCP guidelines. Results: Sensitivity, specificity, positive predictive value, and negative predictive value of ZN staining technique were 84.93%, 95.74%, 96.50%, and 82.16%, respectively, and that of FM was 95.25%, 91.33%, 93.81%, and 93.31%, respectively. Conclusion: LED-FM being more sensitive, especially in detecting the paucibacillary cases and less time-consuming, has advantage over ZN method. Nation-wide implementation will lead to improved diagnosis, thus better control of TB.

[1]  C. Thakur,et al.  Detecting mutation pattern of drug-resistant Mycobacterium tuberculosis isolates in Himachal Pradesh using GenoType® MTBDRplus assay , 2015, Indian journal of medical microbiology.

[2]  M. Banjara,et al.  Rapid Detection of Rifampicin and Isoniazid Resistant Mycobacterium tuberculosis Using Genotype MTBDRplus Assay in Nepal , 2014, International scholarly research notices.

[3]  Zingué Dezemon,et al.  Staining techniques for detection of acid fast bacilli: what hope does fluorescein-diacetate (FDA) vitality staining technique represent for the monitoring of tuberculosis treatment in resource limited settings , 2014 .

[4]  P. Patel,et al.  A Multi-Site Validation in India of the Line Probe Assay for the Rapid Diagnosis of Multi-Drug Resistant Tuberculosis Directly from Sputum Specimens , 2014, PloS one.

[5]  V. Sreenivas,et al.  Comparative Evaluation of GenoType MTBDRplus Line Probe Assay with Solid Culture Method in Early Diagnosis of Multidrug Resistant Tuberculosis (MDR-TB) at a Tertiary Care Centre in India , 2013, PloS one.

[6]  Lokhendro Singh Huidrom,et al.  Detection of Mycobacterium tuberculosis by three methods and their correlation to chest X-ray findings and CD4 T-lymphocyte counts in human immunodeficiency virus-pulmonary tuberculosis coinfection , 2013 .

[7]  F. van Leth,et al.  Comparison of direct versus concentrated smear microscopy in detection of pulmonary tuberculosis , 2013, BMC Research Notes.

[8]  S. Golia,et al.  A COMPARATIVE STUDY OF AURAMINE STAINING USING LED FLUORESCENT MICROSCOPY WITH ZIEHL-NEELSEN STAINING IN THE DIAGNOSIS OF PULMONARY TUBERCULOSIS , 2013 .

[9]  S. Rajasekaran,et al.  COMPARISON OF CONVENTIONAL AND FLUORESCENT STAINING METHODS IN DIAGNOSIS OF PULMONARY TUBERCULOSIS AMONG HIV SEROPOSITIVE INDIVIDUALS , 2012 .

[10]  R. Bharadwaj,et al.  Drug resistance profiles of Mycobacterium tuberculosis isolates to first line anti-tuberculous drugs: A five years study , 2012, Lung India : official organ of Indian Chest Society.

[11]  A. Ramsay,et al.  LED Fluorescence Microscopy for the Diagnosis of Pulmonary Tuberculosis: A Multi-Country Cross-Sectional Evaluation , 2011, PLoS medicine.

[12]  M. O. Odubanjo,et al.  THE MICROBIOLOGICAL DIAGNOSIS OF TUBERCULOSIS IN A RESOURCE - LIMITED SETTING: IS ACID-FAST BACILLI MICROSCOPY ALONE SUFFICIENT? , 2011, Annals of Ibadan postgraduate medicine.

[13]  Hiroyuki Yamada,et al.  [Clinical evaluation of acid-fast smear examination with light emitting diode fluorescent microscopy]. , 2009, Kekkaku : [Tuberculosis].

[14]  Madhukar Pai,et al.  Light-emitting diode technologies for TB diagnosis: what is on the market? , 2009, Expert review of medical devices.

[15]  J. Kovacs,et al.  High Sensitivity and Specificity of Acid-Fast Microscopy for Diagnosis of Pulmonary Tuberculosis in an African Population with a High Prevalence of Human Immunodeficiency Virus , 2009, Journal of Clinical Microbiology.

[16]  D. van Soolingen,et al.  Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in sputum. , 2008, Clinical infectious diseases : an official publication of the Infectious Diseases Society of America.

[17]  A. Kumari,et al.  Efficacy of fluorochrome stain in the diagnosis of pulmonary tuberculosis co-infected with HIV. , 2005, Indian journal of medical microbiology.

[18]  P. Farnia,et al.  Improving Sensitivity of Direct Microscopy for Detection of Acid-Fast Bacilli in Sputum: Use of Chitin in Mucus Digestion , 2002, Journal of Clinical Microbiology.

[19]  G. Aslan,et al.  A comparative study on the different staining methods and number of specimens for the detection of acid fast bacilli. , 2000, Memorias do Instituto Oswaldo Cruz.

[20]  E. Chan,et al.  Immunologic diagnosis of tuberculosis: a review. , 2000, Tubercle and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease.

[21]  P. Cardona,et al.  Evaluation of a commercial probe assay for detection of rifampin resistance inMycobacterium tuberculosis directly from respiratory and nonrespiratory clinical samples , 1998, European Journal of Clinical Microbiology and Infectious Diseases.

[22]  R. Brindle,et al.  Cohort study of HIV-positive and HIV-negative tuberculosis, Nairobi, Kenya: comparison of bacteriological results. , 1992, Tubercle and lung disease : the official journal of the International Union against Tuberculosis and Lung Disease.

[23]  Y. Kazumi,et al.  Comparison of MB-Check, BACTEC, and egg-based media for recovery of mycobacteria , 1992, Kekkaku : [Tuberculosis].

[24]  R. Long,et al.  The impact of HIV on the usefulness of sputum smears for the diagnosis of tuberculosis. , 1991, American journal of public health.

[25]  Anil Kumar,et al.  A Comparison of Ziehl-Neelsen Staining and Fluorescent Microscopy for Diagnosis of Pulmonary Tuberculosis , 2013 .

[26]  D. Armstrong LeD-based fluoroscopy and the ParaLens system: illuminating the future of TB diagnostics , 2010 .

[27]  S. Tripathy Tuberculosis and general practitioners. , 2003, Journal of the Indian Medical Association.

[28]  R. Keller,et al.  MYCOBACTERIAL DISEASES. , 1964, The American journal of roentgenology, radium therapy, and nuclear medicine.