A Novel Wireless Photoplethysmography Blood-Flow Volume Sensor for Assessing Arteriovenous Fistula of Hemodialysis Patients

A novel blood-flow volume (BFV) sensor is presented for assessing quality of arteriovenous fistula in hemodialysis patients via noninvasive reflectance-type photoplethysmography (PPG). BFV is nowadays in clinic practices evaluated using an ultrasound Doppler monitor, which is expensive, bulky, and can only be operated by well-trained medical personnels. This study is devoted to develop a low-cost, small-sized, portable, and easy-to-use PPG sensor that is capable of continuous measurement of BFV. New designs of front-end analog circuits, signal processing, and an intelligent neural network calibration method are employed to finally achieve high correlation (R 2 = 0.7176), as opposed to the ultrasound Doppler monitor, with the root-mean-squared errors successfully controlled under 289 ml/min.

[1]  Johannes J. Struijk,et al.  Stenosis Detection Algorithm for Screening of Arteriovenous Fistulae , 2011 .

[2]  Ming-Jui Wu,et al.  Bilateral photoplethysmography analysis for arteriovenous fistula dysfunction screening with fractional-order feature and cooperative game-based embedded detector. , 2015, Healthcare technology letters.

[3]  Guang-Zhong Yang,et al.  Dual-Mode Additive Noise Rejection in Wearable Photoplethysmography , 2012, 2012 Ninth International Conference on Wearable and Implantable Body Sensor Networks.

[4]  Jian-Xing Wu,et al.  Bilateral photoplethysmography for arterial steal detection in arteriovenous fistula using a fractional-order decision-making quantizer , 2017, Medical & Biological Engineering & Computing.

[5]  L. Durand,et al.  Digital signal processing of the phonocardiogram: review of the most recent advancements. , 1995, Critical reviews in biomedical engineering.

[6]  Chia-Hung Lin,et al.  Arteriovenous Shunt Stenosis Evaluation Using a Fractional-Order Fuzzy Petri Net Based Screening System for Long-Term Hemodialysis Patients , 2014 .

[7]  Halil Berberoglu,et al.  Near infrared laser penetration and absorption in human skin , 2014, Photonics West - Biomedical Optics.

[8]  Jonas Pettersson,et al.  Non-invasive continuous estimation of blood flow changes in human patellar bone , 2006, Medical and Biological Engineering and Computing.

[9]  Eduardo Gil,et al.  Detection of decreases in the amplitude fluctuation of pulse photoplethysmography signal as indication of obstructive sleep apnea syndrome in children , 2008, Biomed. Signal Process. Control..

[10]  Yi-Chun Du,et al.  A Novel Classification Technique of Arteriovenous Fistula Stenosis Evaluation Using Bilateral PPG Analysis , 2016, Micromachines.

[11]  Myoungho Lee,et al.  Relations between ac-dc components and optical path length in photoplethysmography. , 2011, Journal of biomedical optics.

[12]  J B Harness,et al.  Skin photoplethysmography--a review. , 1989, Computer methods and programs in biomedicine.

[13]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[14]  Ashikur Rahman,et al.  Measurement of heart rate using photoplethysmography , 2015, 2015 International Conference on Networking Systems and Security (NSysS).

[15]  Q Li,et al.  Dynamic time warping and machine learning for signal quality assessment of pulsatile signals , 2012, Physiological measurement.

[16]  Bengt Mandersson,et al.  Arteriovenous fistula stenosis detection using wavelets and support vector machines , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[17]  H. Asada,et al.  Utility of the Photoplethysmogram in Circulatory Monitoring , 2008, Anesthesiology.

[18]  journals Iosr,et al.  Blood Flow Analysis Using Ultrasound Doppler Technique , 2015 .

[19]  W. Nichols,et al.  McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles , 1998 .

[20]  K. Venketesh Blood Flow Analysis Using Ultrasound Doppler Technique , 2015 .

[21]  B. Nonnast-Daniel,et al.  Colour Doppler ultrasound in dialysis access. , 2004, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[22]  David Roth,et al.  Inflow stenosis in arteriovenous fistulas and grafts: a multicenter, prospective study. , 2005, Kidney international.

[23]  Bor-Shyh Lin,et al.  Novel Noninvasive Approach for Detecting Arteriovenous Fistula Stenosis , 2014, IEEE Transactions on Biomedical Engineering.

[24]  Hironao Okada,et al.  Development of a Wireless Sensor for the Measurement of Chicken Blood Flow Using the Laser Doppler Blood Flow Meter Technique , 2013, IEEE Transactions on Biomedical Engineering.

[25]  Fulvio Fiorini,et al.  Color Doppler ultrasound and arteriovenous fistulas for hemodialysis , 2014, Journal of Ultrasound.

[26]  Keyvan Hashtrudi-Zaad,et al.  Experimental evaluation of computer-controlled variable gain analog amplifiers , 2016 .

[27]  Wagner Coelho de Albuquerque Pereira,et al.  Continuous flow phantom for the calibration of an ultrasonic transit-time flowmeter , 2014 .

[28]  Renshi Sawada,et al.  Integrated Laser Doppler Blood Flowmeter Designed to Enable Wafer-Level Packaging , 2010, IEEE Transactions on Biomedical Engineering.

[29]  Luis Orozco Programmable-Gain Transimpedance Amplifiers Maximize Dynamic Range in Spectroscopy Systems , 2013 .

[30]  Yonggang Huang,et al.  Epidermal devices for noninvasive, precise, and continuous mapping of macrovascular and microvascular blood flow , 2015, Science Advances.

[31]  Chee Teck Phua,et al.  Non-invasive measurement of blood flow using magnetic disturbance method , 2009, 2009 International Conference on Biomedical and Pharmaceutical Engineering.

[32]  Jayaraj Joseph,et al.  Magnetic sensor for non-invasive detection of blood pulse and estimation of arterial compliance , 2010, 2010 IEEE EMBS Conference on Biomedical Engineering and Sciences (IECBES).

[33]  杨平,et al.  Assessment of Photoplethysmogram Signal Quality Using Morphology Integrated with Temporal Information Approach , 2012 .

[34]  X. Teng,et al.  The effect of contacting force on photoplethysmographic signals , 2004, Physiological measurement.

[35]  F. N. Vosse,et al.  A wave propagation model of blood flow in large vessels using an approximate velocity profile function , 2007, Journal of Fluid Mechanics.

[36]  H Kanai,et al.  Transcutaneous blood flow measurement by electromagnetic induction. , 1974, IEEE transactions on bio-medical engineering.

[37]  Binghuang Cai,et al.  A novel artificial neural network method for biomedical prediction based on matrix pseudo-inversion , 2014, J. Biomed. Informatics.

[38]  L. Wurfel Mcdonald S Blood Flow In Arteries Theoretical Experimental And Clinical Principles , 2016 .

[39]  Lúcio T. Santos,et al.  Automatic Smoothing By Optimal Splines , 2003 .