A Method for Surface Voltage Measurement of an Overhead Insulated Conductor

Surface voltage measurement of an insulated overhead conductor assumes importance for understanding corona, radio interference voltage and for design purposes. Surface voltage measurement of a bare overhead conductor is quite simple as a voltage divider can be directly connected. However, there are challenges in the measurement of surface voltage on an insulating surface of an insulated covered conductor using voltage dividers. In case of ac measurements, the capacitance parameter dominates in deciding the potential distribution. In this article, it is demonstrated that the measuring system itself will alter the voltage division between the capacitance of the cylindrical insulated conductor and that of surrounding air acting as a capacitive divider. The voltage distribution is shown to be drastically influenced by the measuring system capacitance. In view of these issues, a novel experimental method is proposed for the measurement of surface voltage of an overhead insulated covered conductor. In general, the method can be applied to any cylindrical insulated conductor and for calibration of sensor-based measurements. The proposed empirical method is tested by a validated simulation of the entire system and it is proven analytically. The radial voltage gradients are then estimated from measured surface voltages. The analytical, experimental, and simulation results are in close conformity.

[1]  W. A. Thue,et al.  DESIGN AND APPLICATION OF AERIAL SYSTEMS USING INSULATED AND COVERED WIRE AND CABLE , 1996 .

[2]  Boby George,et al.  Feasibility study of a non-contact AC voltage measurement system , 2015, 2015 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings.

[3]  Enrique Mario Spinelli,et al.  Noncontact AC Voltage Measurements: Error and Noise Analysis , 2018, IEEE Transactions on Instrumentation and Measurement.

[4]  Jonas Gloeckner,et al.  Electrical Power Cable Engineering , 2016 .

[5]  G. E. Adams Voltage gradients on high-voltage lines , 1955, Electrical Engineering.

[6]  I. Ramirez-Vazquez,et al.  Electric-Field Analysis of Spacer Cable Systems for Compact Overhead Distribution Lines , 2012, IEEE Transactions on Power Delivery.

[7]  Boonchai Techaumnat,et al.  Study on the field behavior at the contact point between a covered conductor and a dielectric solid , 2011, Proceedings of 2011 International Symposium on Electrical Insulating Materials.

[8]  Jingang Wang,et al.  Method and Experimental Study of Voltage Measurement Based on Electric Field Integral With Gauss–Legendre Algorithm , 2020, IEEE Transactions on Instrumentation and Measurement.

[9]  J. Pihler,et al.  Design of systems of covered overhead conductors by means of electric field calculation , 2005, IEEE Transactions on Power Delivery.

[10]  Zhao Yang Dong,et al.  Analysis of electric field influence on buildings under high-voltage transmission lines , 2016 .

[11]  Deliang Liang,et al.  Implementation of a novel double-side technique for partial discharge detection and location in covered conductor overhead distribution networks , 2015 .

[12]  M. Lehtonen,et al.  Calibration of on-line partial discharge measuring system using Rogowski coil in covered-conductor overhead distribution networks , 2011 .

[13]  William A. Thue,et al.  Electrical Power Cable Engineering, Third Edition , 2016 .

[14]  Thomas Johnson,et al.  Calibrated Single-Contact Voltage Sensor for High-Voltage Monitoring Applications , 2015, IEEE Transactions on Instrumentation and Measurement.

[15]  F. Piazza,et al.  Field Behavior on Polymer-Covered Overhead Conductors Submitted to Natural Aging on Diverse Weather and Geographic Conditions in Brazil , 2009, IEEE Transactions on Power Delivery.

[16]  Boby George,et al.  Development of a Nonintrusive True-RMS AC Voltage Measurement Probe , 2019, IEEE Transactions on Instrumentation and Measurement.

[17]  Qi Li,et al.  Calculating the Surface Potential Gradient of Overhead Line Conductors , 2015, IEEE Transactions on Power Delivery.

[18]  W. A. Thue,et al.  SAFETY CONSIDERATIONS OF AERIAL SYSTEMS USING INSULATED AND COVERED WIRE AND CABLE , 1996 .

[19]  M. Lehtonen,et al.  Modeling and experimental verification of on-line PD detection in MV covered-conductor overhead networks , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.