Effects of photo-induced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on physical properties of cross-linked polyethylene in artificial hip joints

Osteolysis caused by wear particles from polyethylene in the artificial hip joints is a serious issue. We have used photo-induced radical graft polymerization to graft 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer onto the surface of cross-linked polyethylene (CLPE-g-MPC) in order to reduce friction and wear at the bearing surface of the joint. The physical and mechanical properties of CLPE and CLPE-g-MPC were not significantly different, expect that the friction coefficient of untreated CLPE cups was 0.0075, compared with 0.0009 for CLPE-g-MPC cup, an 88% reduction. After 3.0 × 106 cycles in the hip joint simulator test, we could not observe any wear of CLPE-g-MPC cups. We concluded that the advantage of photo-induced radical graft polymerization technique was that the grafted MPC polymer gave a high lubricity only on the surface and has no effect on the bulk properties of the CLPE substrate.

[1]  F. Prati,et al.  Acute and mid‐term results of phosphorylcholine‐coated stents in primary coronary stenting for acute myocardial infarction , 2001, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[2]  D. Sochart,et al.  Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. , 1999, Clinical orthopaedics and related research.

[3]  J. Watanabe,et al.  Polyethylene/phospholipid polymer alloy as an alternative to poly(vinylchloride)-based materials. , 2004, Biomaterials.

[4]  Tomiharu Matsushita,et al.  Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis , 2004, Nature materials.

[5]  K. Ikeuchi,et al.  Influence of proteoglycan contents and of tissue hydration on the frictional characteristics of articular cartilage , 2005, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[6]  N Nakabayashi,et al.  Reduced thrombogenicity of polymers having phospholipid polar groups. , 1990, Journal of biomedical materials research.

[7]  H. Oonishi,et al.  Wear of highly cross-linked polyethylene acetabular cup in Japan. , 2006, The Journal of arthroplasty.

[8]  J M Anderson,et al.  Protein adsorption from human plasma is reduced on phospholipid polymers. , 1991, Journal of biomedical materials research.

[9]  M. Silva,et al.  Short-term in vivo wear of cross-linked polyethylene. , 2004, The Journal of bone and joint surgery. American volume.

[10]  F. Shen,et al.  Development of an extremely wear‐resistant ultra high molecular weight polythylene for total hip replacements , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  W. Harris,et al.  Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). , 1999, Biomaterials.

[12]  T. Boland,et al.  Frictional properties of poly(MPC-co-BMA) phospholipid polymer for catheter applications. , 2003, Biomaterials.

[13]  W H Harris,et al.  A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. , 2001, The Journal of arthroplasty.

[14]  J. Nordrehaug,et al.  Early mobilization after protamine reversal of heparin following implantation of phosphorylcholine-coated stents in totally occluded coronary arteries. , 2000, The American journal of cardiology.

[15]  A. Lewis,et al.  Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation. , 2002, Biomaterials.

[16]  F. Shen,et al.  Irradiation of chemically crosslinked ultrahigh molecular weight polyethylene , 1996 .

[17]  Murali Jasty,et al.  Third-body wear of highly cross-linked polyethylene in a hip simulator. , 2003, The Journal of arthroplasty.

[18]  W. Harris The problem is osteolysis. , 1995, Clinical orthopaedics and related research.

[19]  Kazuhiko Ishihara,et al.  Preparation of Phospholipid Polylners and Their Properties as Polymer Hydrogel Membranes , 1990, Polymer Journal.

[20]  W. Harris,et al.  Polyethylene damage in total knees and use of highly crosslinked polyethylene. , 2003, The Journal of bone and joint surgery. American volume.

[21]  A. Hargens,et al.  Intramuscular Deoxygenation during Exercise in Patients Who Have Chronic Anterior Compartment Syndrome of the Leg* , 1997, The Journal of bone and joint surgery. American volume.

[22]  U. Raviv,et al.  Properties and Interactions of Physigrafted End-Functionalized Poly(ethylene glycol) Layers , 2002 .

[23]  M. Freeman,et al.  Number of polyethylene particles and osteolysis in total joint replacements. A quantitative study using a tissue-digestion method. , 1997, The Journal of bone and joint surgery. British volume.

[24]  S. Incavo,et al.  Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. , 2003, The Journal of arthroplasty.

[25]  Ebihara,et al.  Photoinduced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on polyethylene membrane surface for obtaining blood cell adhesion resistance. , 2000, Colloids and surfaces. B, Biointerfaces.