Compressed sensing reconstruction of cardiac cine MRI using golden angle spiral trajectories.

In dynamic cardiac cine Magnetic Resonance Imaging (MRI), the spatiotemporal resolution is limited by the low imaging speed. Compressed sensing (CS) theory has been applied to improve the imaging speed and thus the spatiotemporal resolution. The purpose of this paper is to improve CS reconstruction of under sampled data by exploiting spatiotemporal sparsity and efficient spiral trajectories. We extend k-t sparse algorithm to spiral trajectories to achieve high spatio temporal resolutions in cardiac cine imaging. We have exploited spatiotemporal sparsity of cardiac cine MRI by applying a 2D+time wavelet-Fourier transform. For efficient coverage of k-space, we have used a modified version of multi shot (interleaved) spirals trajectories. In order to reduce incoherent aliasing artifact, we use different random undersampling pattern for each temporal frame. Finally, we have used nonuniform fast Fourier transform (NUFFT) algorithm to reconstruct the image from the non-uniformly acquired samples. The proposed approach was tested in simulated and cardiac cine MRI data. Results show that higher acceleration factors with improved image quality can be obtained with the proposed approach in comparison to the existing state-of-the-art method. The flexibility of the introduced method should allow it to be used not only for the challenging case of cardiac imaging, but also for other patient motion where the patient moves or breathes during acquisition.

[1]  Peter Boesiger,et al.  Cardiac real‐time imaging using SENSE , 2000 .

[2]  Michael Lustig,et al.  k-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity , 2006 .

[3]  Bo Liu,et al.  Sparsesense: Application of compressed sensing in parallel MRI , 2008, 2008 International Conference on Information Technology and Applications in Biomedicine.

[4]  Yoram Bresler,et al.  MR Image Reconstruction From Highly Undersampled k-Space Data by Dictionary Learning , 2011, IEEE Transactions on Medical Imaging.

[5]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[6]  Sungheon Kim,et al.  Golden‐angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden‐angle radial sampling for fast and flexible dynamic volumetric MRI , 2014, Magnetic resonance in medicine.

[7]  X Hu,et al.  Hybrid technique for dynamic imaging , 2000, Magnetic resonance in medicine.

[8]  Li Feng,et al.  Accelerated cardiac T2 mapping using breath‐hold multiecho fast spin‐echo pulse sequence with k‐t FOCUSS , 2011, Magnetic resonance in medicine.

[9]  M. Lustig,et al.  Compressed Sensing MRI , 2008, IEEE Signal Processing Magazine.

[10]  Hongwei Jin,et al.  Arrhythmia Mechanisms in the Failing Heart , 2008, Pacing and clinical electrophysiology : PACE.

[11]  Shrikanth S. Narayanan,et al.  Flexible retrospective selection of temporal resolution in real‐time speech MRI using a golden‐ratio spiral view order , 2011, Magnetic resonance in medicine.

[12]  Jong Chul Ye,et al.  Radial k‐t FOCUSS for high‐resolution cardiac cine MRI , 2010, Magnetic resonance in medicine.

[13]  Edward V R DiBella,et al.  A Framework for generalized reference image reconstruction methods including HYPR‐LR, PR‐FOCUSS, and k‐t FOCUSS , 2011, Journal of magnetic resonance imaging : JMRI.

[14]  Olaf Dössel,et al.  An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI , 2007, IEEE Transactions on Medical Imaging.

[15]  Jong Chul Ye,et al.  k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI , 2009, Magnetic resonance in medicine.

[16]  Elfar Adalsteinsson,et al.  Simple analytic variable density spiral design , 2003, Magnetic resonance in medicine.

[17]  Hong Jiang,et al.  Dynamic imaging by model estimation , 1997 .

[18]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[19]  Vahid Tarokh,et al.  Compressed sensing reconstruction for undersampled breath‐hold radial cine imaging with auxiliary free‐breathing data , 2014, Journal of magnetic resonance imaging : JMRI.

[20]  E.J. Candes,et al.  An Introduction To Compressive Sampling , 2008, IEEE Signal Processing Magazine.

[21]  R. Edelman,et al.  Signal‐to‐noise ratio and signal‐to‐noise efficiency in SMASH imaging , 1999, Magnetic resonance in medicine.

[22]  D. Nishimura,et al.  Reduced aliasing artifacts using variable‐density k‐space sampling trajectories , 2000, Magnetic resonance in medicine.

[23]  Zhi-Pei Liang,et al.  An efficient method for dynamic magnetic resonance imaging , 1994, IEEE Trans. Medical Imaging.

[24]  Peter Kellman,et al.  Single heartbeat cardiac tagging for the evaluation of transient phenomena , 2005, Magnetic resonance in medicine.

[25]  J. J. van Vaals,et al.  “Keyhole” method for accelerating imaging of contrast agent uptake , 1993, Journal of magnetic resonance imaging : JMRI.

[26]  Peter Boesiger,et al.  k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations , 2003, Magnetic resonance in medicine.

[27]  Leon Axel,et al.  XD‐GRASP: Golden‐angle radial MRI with reconstruction of extra motion‐state dimensions using compressed sensing , 2016, Magnetic resonance in medicine.

[28]  G H Glover,et al.  Simple analytic spiral K‐space algorithm , 1999, Magnetic resonance in medicine.

[29]  M Usman,et al.  k‐t group sparse: A method for accelerating dynamic MRI , 2011, Magnetic resonance in medicine.

[30]  Dwight G Nishimura,et al.  Fast 3D imaging using variable‐density spiral trajectories with applications to limb perfusion , 2003, Magnetic resonance in medicine.

[31]  David Atkinson,et al.  Motion corrected compressed sensing for free‐breathing dynamic cardiac MRI , 2013, Magnetic resonance in medicine.

[32]  Jeffrey A. Fessler,et al.  Nonuniform fast Fourier transforms using min-max interpolation , 2003, IEEE Trans. Signal Process..

[33]  Pablo Irarrazaval,et al.  Reconstruction of undersampled dynamic images by modeling the motion of object elements , 2007, Magnetic resonance in medicine.