Intercomparison of methods to measure the mass concentration of the atmospheric aerosol during INTERCOMP2000: influence of instrumentation and size cuts

Within the EUROTRAC-2 subproject AEROSOL, the intensive field campaign INTERCOMP2000 was conducted to compare aerosol samplers and methods to measure various aerosol properties. Here a comparison of mass concentrations measured with different PM2.5 and PM10 samplers as well as cascade impactors is described. Different filter types were used. In general, the PM2.5 and PM10 mass concentrations obtained on filters agree well. The data agree within 18.1% (PM2.5, all data). If data obtained with the TEOM (18% low) and on Whatman QM-A quartz fibre filters (low face velocity, 38% high) are excluded, PM2.5 data agree within 8.1%. For PM10, the agreement is within 6.6% (again excluding the Whatman QM-A quartz fibre filters, 22% high) or 12.1% (all data). For the impactor samples, the data agreed within 6.3% (excluding the ELPI, which was 92% high) and 8.7% for PM2.5 and PM10.

[1]  Harvey Patashnick,et al.  Continuous PM-10 Measurements Using the Tapered Element Oscillating Microbalance , 1990 .

[2]  M. Sutton,et al.  Ammonia dry deposition over grassland‐micrometeorological flux‐gradient measurements and bidirectional flux calculations using an inferential model , 2001 .

[3]  J. Putaud,et al.  INTERCOMP2000: the comparability of methods in use in Europe for measuring the carbon content of aerosol , 2004 .

[4]  Barbara J. Turpin,et al.  Measuring and simulating particulate organics in the atmosphere: problems and prospects , 2000 .

[5]  Erik Swietlicki,et al.  A closure study of sub-micrometer aerosol particle hygroscopic behaviour , 1999 .

[6]  J. Chow,et al.  Results of the "Carbon Conference" International Aerosol Carbon Round Robin Test Stage I , 2001 .

[7]  J. Cafmeyer,et al.  The ''Gent'' stacked filter unit (SFU) sampler for the collection of atmospheric aerosols in two size fractions: Description and instructions for installation and use , 1994 .

[8]  R. Hillamo,et al.  Nordic intercomparison for measurement of major atmospheric nitrogen species , 1999 .

[9]  I. Uno,et al.  Characterization of atmospheric air pollutants at two sites in northern Kyushu, Japan - Chemical form, and chemical reaction , 2001 .

[10]  Samuel Witz,et al.  Rapid Loss of Particulate Nitrate, Chloride and Ammonium on Quartz Fiber Filters During Storage , 1990 .

[11]  R. Guza,et al.  Observations of turbulence in the surf zone , 1994 .

[12]  Peter H. McMurry,et al.  A review of atmospheric aerosol measurements , 2000 .

[13]  K. H. Fung,et al.  Phase transformation and metastability of hygroscopic microparticles , 1995 .

[14]  Delbert J. Eatough,et al.  Semi-volatile secondary organic aerosol in urban atmospheres: meeting a measurement challenge , 2003 .

[15]  Jorma Keskinen,et al.  Electrical low pressure impactor , 1992 .

[16]  K. Müller A 3 year study of the aerosol in northwest Saxony (Germany) , 1999 .

[17]  J. Cafmeyer,et al.  Aerosol chemical mass closure during the EUROTRAC-2 AEROSOL Intercomparison 2000 , 2002 .

[18]  W. Maenhaut,et al.  INTERCOMP2000, a campaign to assess the comparability of methods in use in Europe for measuring aerosol composition , 2004 .

[19]  Kenneth L. Rubow,et al.  A Microorifice Uniform Deposit Impactor (MOUDI): Description, Calibration, and Use , 1991 .

[20]  Sheldon Landsberger,et al.  Characterization of the Gent Stacked Filter Unit PM10 Sampler , 1997 .

[21]  I. Tang,et al.  Water activities, densities, and refractive indices of aqueous sulfates and sodium nitrate droplets of atmospheric importance , 1994 .

[22]  Michael Schulz,et al.  Artefacts in the sampling of nitrate studied in the INTERCOMP campaigns of EUROTRAC-AEROSOL , 2004 .

[23]  Gottfried Hänel,et al.  The Properties of Atmospheric Aerosol Particles as Functions of the Relative Humidity at Thermodynamic Equilibrium with the Surrounding Moist Air , 1976 .