Estimating running spatial and temporal parameters using an inertial sensor

An inertial measurement unit (IMU) is widely considered to be an economical alternative to capture human motion in daily activities. Use of an IMU for clinical study, rehabilitation, and in the design of orthoses and prostheses has increased tremendously. However, its use in defining running gait is limited. This study presents a practical method to estimate running spatial and temporal parameters using an inertial sensor by placing it on a shoe. A combination of a zero-crossing method and thresholding is used to identify foot-strike and foot-off based on foot acceleration during running. Stride time, ground contact time and flight time can then be identified. An off-phase segmentation algorithm is applied to estimate stride length and running speed. These two parameters are commonly used to evaluate running efficiency and to differentiate elite runners. This study found that an IMU can estimate foot-strike and foot-off with average absolute time differences of 2.60–6.04 and 2.61–16.28 ms, respectively. Stride time was estimated with error between − 4.04 and 0.33 ms. Stride length and running speed were estimated with maximum average errors of 45.97 mm and 0.41 km/h.

[1]  Jean-Benoit Morin,et al.  Reliability and validity of the Myotest® for measuring running stride kinematics , 2016, Journal of sports sciences.

[2]  Pedro Pérez-Soriano,et al.  Effect of overground vs treadmill running on plantar pressure: influence of fatigue. , 2013, Gait & posture.

[3]  A. Schache,et al.  A comparison of overground and treadmill running for measuring the three-dimensional kinematics of the lumbo-pelvic-hip complex. , 2001, Clinical biomechanics.

[4]  Irene S Davis,et al.  Comparison of methods for kinematic identification of footstrike and toe-off during overground and treadmill running. , 2010, Journal of science and medicine in sport.

[5]  Darwin Gouwanda,et al.  Investigating running gait using a shoe-integrated wireless inertial sensor , 2015, TENCON 2015 - 2015 IEEE Region 10 Conference.

[6]  T. Keränen,et al.  Factors related to top running speed and economy. , 2007, International journal of sports medicine.

[7]  Shuozhi Yang,et al.  Ambulatory running speed estimation using an inertial sensor. , 2011, Gait & posture.

[8]  Alpha Agape Gopalai,et al.  A robust real-time gait event detection using wireless gyroscope and its application on normal and altered gaits. , 2015, Medical engineering & physics.

[9]  Hélène Pillet,et al.  Estimation of temporal parameters during sprint running using a trunk-mounted inertial measurement unit. , 2012, Journal of biomechanics.

[10]  D. Kerrigan,et al.  A kinematics and kinetic comparison of overground and treadmill running. , 2008, Medicine and science in sports and exercise.

[11]  M E Batt,et al.  Surface effects on ground reaction forces and lower extremity kinematics in running. , 2000, Medicine and science in sports and exercise.

[12]  Paola Zamparo,et al.  Accuracy of a 10 Hz GPS Unit in Measuring Shuttle Velocity Performed at Different Speeds and Distances (5 – 20 M) , 2016, Journal of human kinetics.

[13]  Brendan J Burkett,et al.  The use of a single inertial sensor to identify stride, step, and stance durations of running gait. , 2010, Journal of science and medicine in sport.

[14]  Julie Stebbins,et al.  Identifying gait events without a force plate during running: a comparison of methods. , 2011, Gait & posture.

[15]  Reed Ferber,et al.  Predicting timing of foot strike during running, independent of striking technique, using principal component analysis of joint angles. , 2014, Journal of biomechanics.

[16]  A. Hreljac,et al.  Phase determination during normal running using kinematic data , 2006, Medical and Biological Engineering and Computing.

[17]  Daniel Arthur James,et al.  Validation of trunk mounted inertial sensors for analysing running biomechanics under field conditions, using synchronously collected foot contact data , 2010 .

[18]  Q Li,et al.  Walking speed estimation using a shank-mounted inertial measurement unit. , 2010, Journal of biomechanics.