Heat transfer across the wall of dividing wall columns

We address heat transfer across the wall of the dividing wall column. Heat flows through the column are analysed and used to identify regions of the wall at which the horizontal heat transfer has beneficial and detrimental effects. The results of a case study show that energy savings of the order of 10% are possible by installing insulation at the appropriate part of the dividing wall