Automated finite element meshing of the lumbar spine: Verification and validation with 18 specimen-specific models.

The purpose of this study was to seek broad verification and validation of human lumbar spine finite element models created using a previously published automated algorithm. The automated algorithm takes segmented CT scans of lumbar vertebrae, automatically identifies important landmarks and contact surfaces, and creates a finite element model. Mesh convergence was evaluated by examining changes in key output variables in response to mesh density. Semi-direct validation was performed by comparing experimental results for a single specimen to the automated finite element model results for that specimen with calibrated material properties from a prior study. Indirect validation was based on a comparison of results from automated finite element models of 18 individual specimens, all using one set of generalized material properties, to a range of data from the literature. A total of 216 simulations were run and compared to 186 experimental data ranges in all six primary bending modes up to 7.8Nm with follower loads up to 1000N. Mesh convergence results showed less than a 5% difference in key variables when the original mesh density was doubled. The semi-direct validation results showed that the automated method produced results comparable to manual finite element modeling methods. The indirect validation results showed a wide range of outcomes due to variations in the geometry alone. The studies showed that the automated models can be used to reliably evaluate lumbar spine biomechanics, specifically within our intended context of use: in pure bending modes, under relatively low non-injurious simulated in vivo loads, to predict torque rotation response, disc pressures, and facet forces.

[1]  Antonius Rohlmann,et al.  Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method. , 2006, Journal of biomechanics.

[2]  Benjamin J. Ellis,et al.  Verification, validation and sensitivity studies in computational biomechanics , 2007, Computer methods in biomechanics and biomedical engineering.

[3]  M. Pearcy,et al.  Three-Dimensional X-ray Analysis of Normal Movement in the Lumbar Spine , 1984, Spine.

[4]  Thomas R Oxland,et al.  Accuracy and repeatability of a new method for measuring facet loads in the lumbar spine. , 2006, Journal of biomechanics.

[5]  H. Wilke,et al.  Geometry strongly influences the response of numerical models of the lumbar spine--a probabilistic finite element analysis. , 2012, Journal of biomechanics.

[6]  M. Viceconti,et al.  Extracting clinically relevant data from finite element simulations. , 2005, Clinical biomechanics.

[7]  M J Pearcy,et al.  Nonlinear finite element analysis of anular lesions in the L4/5 intervertebral disc. , 2007, Journal of biomechanics.

[8]  Neil R Crawford,et al.  The use of surface strain data and a neural networks solution method to determine lumbar facet joint loads during in vitro spine testing. , 2008, Journal of biomechanics.

[9]  M. Pearcy,et al.  Axial rotation and lateral bending in the normal lumbar spine measured by three-dimensional radiography. , 1984, Spine.

[10]  Alison C Jones,et al.  Finite element analysis of the spine: towards a framework of verification, validation and sensitivity analysis. , 2008, Medical engineering & physics.

[11]  Anthony J. Petrella,et al.  An Automated Method for Landmark Identification and Finite-Element Modeling of the Lumbar Spine , 2015, IEEE Transactions on Biomedical Engineering.

[12]  Lutz Claes,et al.  Stepwise reduction of functional spinal structures increase vertebral translation and intradiscal pressure. , 2007, Journal of biomechanics.

[13]  P. Nair,et al.  A large scale finite element study of a cementless osseointegrated tibial tray. , 2013, Journal of biomechanics.

[14]  Heath B. Henninger,et al.  Validation of computational models in biomechanics , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[15]  Yifei Dai,et al.  Incorporating population-level variability in orthopedic biomechanical analysis: a review. , 2014, Journal of biomechanical engineering.

[16]  Paul J. Rullkoetter,et al.  Stepwise Validated Finite Element Model of the Human Lumbar Spine , 2013 .

[17]  J. Cegoñino,et al.  A Constitutive Model for the Annulus of Human Intervertebral Disc: Implications for Developing a Degeneration Model and Its Influence on Lumbar Spine Functioning , 2014, J. Appl. Math..

[18]  M. Doblaré,et al.  An accurate validation of a computational model of a human lumbosacral segment. , 2010, Journal of biomechanics.

[19]  Christian M. Puttlitz,et al.  Parametric convergence sensitivity and validation of a finite element model of the human lumbar spine , 2011, Computer methods in biomechanics and biomedical engineering.

[20]  A Rohlmann,et al.  Comparison of eight published static finite element models of the intact lumbar spine: predictive power of models improves when combined together. , 2014, Journal of biomechanics.

[21]  Gerhard A. Holzapfel,et al.  An Anisotropic Model for Annulus Tissue and Enhanced Finite Element Analyses of Intact Lumbar Disc Bodies , 2001 .

[22]  Ahmet Erdemir,et al.  Considerations for reporting finite element analysis studies in biomechanics. , 2012, Journal of biomechanics.

[23]  E. Teo,et al.  Material Sensitivity Study on Lumbar Motion Segment (L2-L3) Under Sagittal Plane Loadings Using Probabilistic Method , 2005, Journal of spinal disorders & techniques.

[24]  L Claes,et al.  Influence of a Follower Load on Intradiscal Pressure and Intersegmental Rotation of the Lumbar Spine , 2001, Spine.

[25]  Thomas R Oxland,et al.  The Effect of Dynamic Posterior Stabilization on Facet Joint Contact Forces: An In Vitro Investigation , 2008, Spine.

[26]  Alexander Tsouknidas,et al.  The effect of kyphoplasty parameters on the dynamic load transfer within the lumbar spine considering the response of a bio-realistic spine segment. , 2013, Clinical biomechanics.

[27]  Damien Lacroix,et al.  Regional annulus fibre orientations used as a tool for the calibration of lumbar intervertebral disc finite element models , 2013, Computer methods in biomechanics and biomedical engineering.

[28]  Wafa Skalli,et al.  Influence of an auxiliary facet system on intervertebral discs and adjacent facet joints. , 2013, The spine journal : official journal of the North American Spine Society.

[29]  A Shirazi-Adl,et al.  Analysis of large compression loads on lumbar spine in flexion and in torsion using a novel wrapping element. , 2006, Journal of biomechanics.

[30]  P Brinckmann,et al.  Change of disc height, radial disc bulge, and intradiscal pressure from discectomy. An in vitro investigation on human lumbar discs. , 1991, Spine.

[31]  M. Fröhlich,et al.  Multi-segment FEA of the human lumbar spine including the heterogeneity of the annulus fibrosus , 2004 .

[32]  A. A. Zadpoor,et al.  Statistical shape and appearance models of bones. , 2014, Bone.

[33]  L. Claes,et al.  Intradiscal pressure together with anthropometric data--a data set for the validation of models. , 2001, Clinical biomechanics.

[34]  P. Regitnig,et al.  Single lamellar mechanics of the human lumbar anulus fibrosus , 2005, Biomechanics and modeling in mechanobiology.

[35]  Narayan Yoganandan,et al.  Moment-rotation responses of the human lumbosacral spinal column. , 2007, Journal of biomechanics.

[36]  M. Pearcy Stereo radiography of lumbar spine motion. , 1985, Acta orthopaedica Scandinavica. Supplementum.