Microbiologically Induced Corrosive Properties of the Titanium Surface

Corrosion of titanium is the major concern when it is used for dental treatment. This study aimed to investigate the mechanism of the microbiologically induced corrosive properties of titanium. An experimental well was made of polymethyl methacrylate with pure titanium at the bottom. Viable or killed cells of Streptococcus mutans were packed into the well, and pH at the bacteria-titanium interface was monitored with and without glucose. Before and after 90-minute incubation, the electrochemical behavior on the titanium surface was measured by means of a potentiostat. The oxygen concentration under bacterial cells was monitored with oxygen-sensitive fluorescent film. The amount of titanium eluted was measured by inductively coupled plasma-mass spectrometry. The corrosion current and passive current under killed cells were low and stable during 90 min, while those under viable cells increased, regardless of the glucose-induced pH fall. The polarization resistance and oxygen concentration under killed cells were high and stable, while those under viable cells decreased. No elution of titanium was detected. Viable bacterial cells may form ‘oxygen concentration cells’ through metabolism-coupled oxygen consumption and subsequently induce corrosive properties of the titanium surface.

[1]  Shujun Li,et al.  Corrosion behavior of biomedical Ti-24Nb-4Zr-8Sn alloy in different simulated body solutions. , 2013, Materials science & engineering. C, Materials for biological applications.

[2]  Fu-qiang Zhang,et al.  Corrosion behavior of pure titanium in the presence of Actinomyces naeslundii , 2013, Journal of Materials Science: Materials in Medicine.

[3]  N. Takahashi,et al.  Evaluation of pH at the Bacteria–Dental Cement Interface , 2011, Journal of dental research.

[4]  W. Teughels,et al.  Do oral biofilms influence the wear and corrosion behavior of titanium? , 2010, Biofouling.

[5]  H. Jenkinson,et al.  The effects of polishing methods on surface morphology, roughness and bacterial colonisation of titanium abutments , 2007, Journal of materials science. Materials in medicine.

[6]  A. Piattelli,et al.  A 16-year study of the microgap between 272 human titanium implants and their abutments. , 2005, The Journal of oral implantology.

[7]  H. Videla,et al.  Microbiologically influenced corrosion: looking to the future. , 2005, International microbiology : the official journal of the Spanish Society for Microbiology.

[8]  Joseph S Guindy,et al.  Corrosion at the marginal gap of implant-supported suprastructures and implant failure. , 2004, The International journal of oral & maxillofacial implants.

[9]  J. Bearinger,et al.  Effect of hydrogen peroxide on titanium surfaces: in situ imaging and step-polarization impedance spectroscopy of commercially pure titanium and titanium, 6-aluminum, 4-vanadium. , 2003, Journal of biomedical materials research. Part A.

[10]  M. Textor,et al.  Comparative investigation of the surface properties of commercial titanium dental implants. Part I: chemical composition , 2002, Journal of materials science. Materials in medicine.

[11]  M. Koike,et al.  The corrosion resistance of pure titanium in organic acids. , 2001, Biomaterials.

[12]  M. Péoc'h,et al.  Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement* , 2000, The Journal of bone and joint surgery. American volume.

[13]  S. Steinemann Titanium--the material of choice? , 1998, Periodontology 2000.

[14]  D. Thierry,et al.  Corrosion resistance for biomaterial applications of TiO2 films deposited on titanium and stainless steel by ion-beam-assisted sputtering. , 1997, Journal of biomedical materials research.

[15]  I. Kleinberg,et al.  Stoichiometry of oxygen consumption and sugar, organic acid and amino acid utilization in salivary sediment and pure cultures of oral bacteria. , 1996, Archives of oral biology.

[16]  M. Raupach CHLORIDE-INDUCED MACROCELL CORROSION OF STEEL IN CONCRETE - THEORETICAL BACKGROUND AND PRACTICAL CONSEQUENCES , 1996 .

[17]  J. Rodrigo,et al.  Immune Response to Synthetic Materials: Sensitization of Patients Receiving Orthopaedic Implants , 1996, Clinical orthopaedics and related research.

[18]  D. Thierry,et al.  Hydrogen peroxide toward enhanced oxide growth on titanium in PBS solution: blue coloration and clinical relevance. , 1996, Journal of biomedical materials research.

[19]  D van Steenberghe,et al.  Microbial penetration along the implant components of the Brånemark system. An in vitro study. , 1994, Clinical oral implants research.

[20]  R. Balsara,et al.  Pacemaker contact sensitivity: clinical recognition and management. , 1994, The Annals of thoracic surgery.

[21]  T. Yamada,et al.  Metabolism of intracellular polysaccharide in the cells of Streptococcus mutans under strictly anaerobic conditions. , 1991, Oral microbiology and immunology.

[22]  B. Kasemo,et al.  Biomaterial and implant surfaces: on the role of cleanliness, contamination, and preparation procedures. , 1988, Journal of biomedical materials research.

[23]  M F Baslé,et al.  Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium. , 2006, Acta biomaterialia.

[24]  M. Freeman,et al.  Sensitivity to titanium. A cause of implant failure? , 1991, The Journal of bone and joint surgery. British volume.

[25]  J. Carlsson,et al.  Oxygen and the sugar metabolism in oral streptococci. , 1991, Proceedings of the Finnish Dental Society. Suomen Hammaslaakariseuran toimituksia.

[26]  R. Jarman,et al.  THE BASIC PRINCIPLES OF CORROSION , 1987 .