Data Sampling System with High Speed and High Timing Synchronization Precision for Power Line Fault Position Detection based on Dual Ports Traveling Wave Distance Measurement Method
暂无分享,去创建一个
This paper presents a scheme of data sampling based on DSP and FPGA. We use very high stable oscillator and FPGA to divide the interval between the neighboring second pulses and get the more precision synchronization pulse. This method can also use for the status of GPS signal disappearance. The test result indicates that it can keep 1 muS precision during tow hours in the condition without GPS signal. For the wave head location, a good result has be gotten using maximum SNR filtering method. The method can be used for many other signals processing, especially, for the condition that the useful signal is well known and the SNR is ultra-low
[1] N. C. Pahalawaththa,et al. Effects of frequency dependence and line parameters on single ended travelling wave based fault location schemes , 1992 .
[2] A. T. Johns,et al. A novel fault locator based on the detection of fault generated high frequency transients , 1997 .
[3] R. S. Bucy,et al. Filtering and its Applications , 1970 .
[4] Zhiqian Bo,et al. Accurate fault location technique for distribution system using fault-generated high-frequency transient voltage signals , 1999 .