Transposed firing activation of motor units.

Muscles are composed of groups of muscle fibers, called motor units, each innervated by a single motoneuron originating in the spinal cord. During constant or linearly varying voluntary force contractions, motor units are activated in a hierarchical order, with the earlier-recruited motor units having greater firing rates than the later-recruited ones. We found that this normal pattern of firing activation can be altered during oscillatory contractions where the force oscillates at frequencies ≥2 Hz. During these high-frequency oscillations, the activation of the lower-threshold motor units effectively decreases and that of the higher-threshold motor units effectively increases. This transposition of firing activation provides means to activate higher-threshold motor units preferentially. Our results demonstrate that the hierarchical regulation of motor unit activation can be manipulated to activate specific motoneuron populations preferentially. This finding can be exploited to develop new forms of physical therapies and exercise programs that enhance muscle performance or that target the preferential atrophy of high-threshold motor units as a result of aging or motor disorders such as stroke and amyotrophic lateral sclerosis.

[1]  C. Christakos,et al.  Occurrence of widespread motor-unit firing correlations in muscle contractions: their role in the generation of tremor and time-varying voluntary force. , 1999, Journal of neurophysiology.

[2]  Joshua C. Kline,et al.  Decomposition of surface EMG signals. , 2006, Journal of neurophysiology.

[3]  Karl M. Newell,et al.  Coherence of EMG activity and single motor unit discharge patterns in human rhythmical force production , 2005, Behavioural Brain Research.

[4]  W. Rymer,et al.  Accuracy assessment of a surface electromyogram decomposition system in human first dorsal interosseus muscle , 2014, Journal of neural engineering.

[5]  Carlo J De Luca,et al.  Neural control of muscle force: indications from a simulation model. , 2013, Journal of neurophysiology.

[6]  C. D. De Luca,et al.  Behaviour of human motor units in different muscles during linearly varying contractions , 1982, The Journal of physiology.

[7]  L. Larsson,et al.  Fatigue of chronically overused motor units in prior polio patients , 1996, Muscle & nerve.

[8]  William Z Rymer,et al.  Assessment of validity of a high-yield surface electromyogram decomposition , 2013, Journal of NeuroEngineering and Rehabilitation.

[9]  C. D. De Luca,et al.  Control scheme governing concurrently active human motor units during voluntary contractions , 1982, The Journal of physiology.

[10]  H. Hultborn,et al.  Integration in Spinal Neuronal Systems , 2011 .

[11]  William Z Rymer,et al.  Motor unit pool organization examined via spike-triggered averaging of the surface electromyogram. , 2013, Journal of neurophysiology.

[12]  A. Kimura,et al.  Motor unit firing behavior in slow and fast contractions of the first dorsal interosseous muscle of healthy men. , 1995, Electroencephalography and clinical neurophysiology.

[13]  C. D. De Luca,et al.  Hierarchical control of motor units in voluntary contractions. , 2012, Journal of neurophysiology.

[14]  M. Kiernan,et al.  Fatigue and activity dependent changes in axonal excitability in amyotrophic lateral sclerosis , 2007, Journal of Neurology, Neurosurgery, and Psychiatry.

[15]  Claude Ghez,et al.  Coherent modulations of human motor unit discharges during quasi-sinusoidal isometric muscle contractions , 1994, Neuroscience Letters.

[16]  M. Illert,et al.  Absence of recurrent axon collaterals in motoneurones to the extrinsic digit extensor muscles of the cat forelimb , 1991, Neuroscience Letters.

[17]  C. D. De Luca,et al.  Influence of proprioceptive feedback on the firing rate and recruitment of motoneurons , 2012, Journal of neural engineering.

[18]  C. D. De Luca,et al.  High-yield decomposition of surface EMG signals , 2010, Clinical Neurophysiology.

[19]  P Girlanda,et al.  Muscle rearrangement in patients with hemiparesis after stroke: an electrophysiological and morphological study. , 1993, European neurology.

[20]  Norway. , 1988, Revue scientifique et technique.

[21]  R. Person,et al.  Discharge frequency and discharge pattern of human motor units during voluntary contraction of muscle. , 1972, Electroencephalography and clinical neurophysiology.

[22]  E Stålberg,et al.  Macro EMG in healthy subjects of different ages. , 1982, Journal of neurology, neurosurgery, and psychiatry.

[23]  G. Hagg,et al.  Static work loads and occupational myalgia a new explanation model , 1991 .

[24]  C. D. De Luca,et al.  Relationship between firing rate and recruitment threshold of motoneurons in voluntary isometric contractions. , 2010, Journal of neurophysiology.

[25]  A. Rossi,et al.  Distribution of recurrent inhibition in the human upper limb. , 1993, Acta physiologica Scandinavica.

[26]  R. Katz,et al.  Recurrent inhibition in humans , 1999, Progress in Neurobiology.

[27]  C. Gielen,et al.  Motor unit firing behavior in human arm flexor muscles during sinusoidal isometric contractions and movements , 1997, Experimental Brain Research.

[28]  Zeynep Erim,et al.  Common drive of motor units in regulation of muscle force , 1994, Trends in Neurosciences.

[29]  E. Henneman Relation between size of neurons and their susceptibility to discharge. , 1957, Science.

[30]  K. Newell,et al.  Intermittency of Visual Information and the Frequency of Rhythmical Force Production , 2005, Journal of motor behavior.