Long-term stability of the APS storage ring

The Advanced Photon Source (APS), a third-generation synchrotrons light source, was commissioned in 1995 at Argonne ''National Laboratory and has been fully-operational for beamline users since 1997. The APS storage ring can accommodate up to 68 user beamlines; about 70% of the available beamlines are currently in use by various collaborative access teams (CATS). The 7-GeV synchrotrons light source produces light in the soft to hard x-ray range that is used for research in such areas as x-ray instrumentation; material, chemical and atomic sciences; biology; and geo/soil/ environmental sciences. For the successful operation of an x-ray light source such as the Advanced Photon Source, the long-term stability of the concrete floor supporting the beam components and user beamlines is crucial. Settlements impact the orbit and location of the x-ray source points as well as the position of the x-ray beamlines. This paper compares the results of two successive resurveys of the APS accelerator components performed in 1995 and 1998.