Performance analysis of adaptive band hysteresis current controller for shunt active power filter

Power Distribution system is polluted by harmonic and reactive power disturbances due to the large usages of non-linear loads (Computers, Laser printers, SMPS, Rectifier etc.). Harmonics cause a number of undesirable effects like heating, equipment damage and Electromagnetic Interference effects in the power system. Active power filter (APF) or Active power line conditioner (APLC) is a suitable solution to compensate for the adverse effects of harmonics and reactive power simultaneously. Synchronous reference frame (SRF) theory is adopted for extracting fundamental components. In this paper, a comparative study of the performances of two current control strategies namely the hysteresis current controller (HCC) and adaptive hysteresis current controller (AHCC) is carried out and superior features of AHCC are established. Results of simulation studies on the performances of HCC and AHCC are included to demonstrate the effectiveness of using adaptive hysteresis band.

[1]  Luis Moran,et al.  A three-phase active power filter operating with fixed switching frequency for reactive power and current harmonic compensation , 1995, IEEE Trans. Ind. Electron..

[2]  P. J. Rose,et al.  Harmonics: the effects on power quality and transformers , 1994 .

[3]  Murat Kale,et al.  An adaptive hysteresis band current controller for shunt active power filter , 2005 .

[4]  Hurng-Liahng Jou,et al.  A novel active power filter for harmonic suppression , 2005 .

[5]  S. Rahmani,et al.  A Three-Phase Shunt Active Power Filter for Damping of Harmonic Propagation in Power Distribution Systems , 2006, 2006 IEEE International Symposium on Industrial Electronics.

[6]  H.-L. Jou,et al.  Simplified control method for the single-phase active power filter , 1996 .

[7]  C. Liaw,et al.  Random hysteresis PWM inverter with robust spectrum shaping , 2001 .

[8]  Donald W. Novotny,et al.  Current Control of VSI-PWM Inverters , 1985, IEEE Transactions on Industry Applications.

[9]  Bimal K. Bose,et al.  An Adaptive Hysteresis-Band Current Control Technique of a Voltage-Fed Pwm Inverter for Machine Drive System , 1988, Proceedings.14 Annual Conference of Industrial Electronics Society.

[10]  R. D. Henderson,et al.  Harmonics: the effects on power quality and transformers , 1994, [Proceedings] IEEE 1993 Annual Textile, Fiber and Film Industry Technical Conference.

[11]  G. Bhuvaneswari,et al.  Comparison of Three Phase Shunt Active Power Filter Algorithms , 2010 .

[12]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[13]  Hirofumi Akagi Trends in active power line conditioners , 1994 .