A High Sensitivity Preamplifier for Quartz Tuning Forks in QEPAS (Quartz Enhanced PhotoAcoustic Spectroscopy) Applications

All the preamplifiers dedicated for Quartz Enhanced PhotoAcoustic Spectroscopy (QEPAS) applications that have so far been reported in the literature have been based on operational amplifiers working in transimpedance configurations. Taking into consideration that QEPAS sensors are based on quartz tuning forks, and that quartz has a relatively high voltage constant and relatively low charge constant, it seems that a transimpedance amplifier is not an optimal solution. This paper describes the design of a quartz QEPAS sensor preamplifier, implemented with voltage amplifier configuration. Discussion of an electrical model of the circuit and preliminary measurements are presented. Both theoretical analysis and experiments show that use of the voltage configuration allows for a substantial increase of the output signal in comparison to the transimpedance circuit with the same tuning fork working in identical conditions. Assuming that the sensitivity of the QEPAS technique depends directly on the properties of the preamplifier, use of the voltage amplifier configuration should result in an increase of QEPAS sensitivity by one to two orders of magnitude.

[1]  Y.S. Shmaliy One-port noise model of a crystal oscillator , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  Jan Tichý,et al.  Principles of Piezoelectricity , 2010 .

[3]  Frank K. Tittel,et al.  Quartz-Enhanced Photoacoustic Spectroscopy: A Review , 2014, Sensors.

[4]  J.-M. Friedt,et al.  Introduction to the quartz tuning fork , 2007 .

[5]  Wenzhe Jiang,et al.  Double acoustic microresonator quartz-enhanced photoacoustic spectroscopy. , 2014, Optics letters.

[6]  J. Reuss,et al.  LASER PHOTOACOUSTIC TRACE GAS DETECTION, AN EXTREMELY SENSITIVE TECHNIQUE APPLIED IN BIOLOGICAL RESEARCH , 1998 .

[7]  A. Kosterev,et al.  Applications of quartz tuning forks in spectroscopic gas sensing , 2005 .

[8]  Benli Yu,et al.  Applications of Absorption Spectroscopy Using Quantum Cascade Lasers , 2014, Applied spectroscopy.

[9]  Philip A. Martin,et al.  Tunable diode laser monitoring of atmospheric trace gas constituents , 1995 .

[10]  A. Kosterev,et al.  Quartz-enhanced photoacoustic spectroscopy. , 2002, Optics letters.

[11]  Tomasz Starecki,et al.  Analog Front-End Circuitry in Piezoelectric and Microphone Detection of Photoacoustic Signals , 2014 .

[12]  Frank K. Tittel,et al.  QEPAS for chemical analysis of multi-component gas mixtures , 2010 .

[13]  Vincenzo Spagnolo,et al.  Photoacoustic Techniques for Trace Gas Sensing Based on Semiconductor Laser Sources , 2009, Sensors.

[14]  Frank K. Tittel,et al.  Analysis of the electro-elastic properties of custom quartz tuning forks for optoacoustic gas sensing , 2016 .

[15]  M. Sigrist Trace gas monitoring by laser photoacoustic spectroscopy and related techniques (plenary) , 2003 .

[16]  Zbigniew Bielecki,et al.  Application of quantum cascade lasers to trace gas detection , 2015 .

[17]  Drago Strle,et al.  Sensitivity Comparison of Vapor Trace Detection of Explosives Based on Chemo-Mechanical Sensing with Optical Detection and Capacitive Sensing with Electronic Detection , 2014, Sensors.