A 0.034% Charge-Imbalanced Neural Stimulation Front-End (SFE) IC With on-Chip Voltage Compliance Monitoring Circuit and Analysis on Resting Potential by Utilizing the SFE IC

The proposed SFE IC adopts an eight-channel H-bridge structure with an integrated voltage compliance monitoring circuit. It has stimulation current ranged from 0.78mA to 6.2mA selected by 3b control and the stimulation current level can be controlled with 7b resolution within a selected current range. The current range can be expanded by using a high current option ranged from 2.71mA to 21.7mA under 3b control. The worst DNL and INL of the stimulation current source are 0.32 LSB and 0.3 LSB, respectively, from all the current ranges. The average mismatch between the cathodic and anodic current pulses in a biphasic stimulus is measured as 0.034% without using charge balancing techniques. The voltage compliance monitoring circuit is based on triode detection of a sensing MOSFET and it shows the detection accuracy of 45mV from its measurement results. The maximum steady-state voltage across the electrodes/ solution interface (resting potential) is also rigorously analyzed and verified through bench-top and saline experiments by utilizing the proposed stimulator. The SFE IC was fabricated in $0.18~\mu \text{m}$ 24 V CMOS process.

[1]  Daniel R. Merrill,et al.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols , 2005, Journal of Neuroscience Methods.

[2]  Richard B. Stein,et al.  Impedance Properties of Metal Electrodes for Chronic Recording from Mammalian Nerves , 1978, IEEE Transactions on Biomedical Engineering.

[3]  Timothy G. Constandinou,et al.  A partial-current-steering biphasic stimulation driver for neural prostheses , 2008, 2008 IEEE International Symposium on Circuits and Systems.

[4]  Warren M Grill,et al.  Impedance characteristics of deep brain stimulation electrodes in vitro and in vivo , 2009, Journal of neural engineering.

[5]  Daniel Mayer Hamilton´s principle and electric circuits Tudory , 2011 .

[6]  E. Buchser,et al.  Spinal Cord Stimulation for the Treatment of Chronic Pain in Patients with Lumbar Spinal Stenosis , 2010, Neuromodulation : journal of the International Neuromodulation Society.

[7]  P. Veronesi Classical Dynamics of Particles and Systems , 1971 .

[8]  Maurits Ortmanns,et al.  An Active Approach for Charge Balancing in Functional Electrical Stimulation , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[9]  Seth R. Sanders,et al.  Short Course: Embedded Power Management for IC Designers , 2008, ISSCC 2008.

[10]  Maurits Ortmanns,et al.  A Neural Stimulator Frontend With High-Voltage Compliance and Programmable Pulse Shape for Epiretinal Implants , 2012, IEEE Journal of Solid-State Circuits.

[11]  Hoi-Jun Yoo,et al.  A Sub-10 nA DC-Balanced Adaptive Stimulator IC With Multi-Modal Sensor for Compact Electro-Acupuncture Stimulation , 2012, IEEE Transactions on Biomedical Circuits and Systems.

[12]  Yiannos Manoli,et al.  A 22 V Compliant 56 ${\mu}$ W Twin-Track Active Charge Balancing Enabling 100% Charge Compensation Even in Monophasic and 36% Amplitude Correction in Biphasic Neural Stimulators , 2018, IEEE Journal of Solid-State Circuits.

[13]  Matthew D. Johnson,et al.  In vivo impedance spectroscopy of deep brain stimulation electrodes , 2009, Journal of neural engineering.

[14]  C Toumazou,et al.  Offset prediction for charge-balanced stimulus waveforms , 2011, Journal of neural engineering.

[15]  Hyung-Min Lee,et al.  A Piecewise Linear 10 Bit DAC Architecture With Drain Current Modulation for Compact LCD Driver ICs , 2009, IEEE Journal of Solid-State Circuits.

[16]  Peng Li,et al.  A pulse-width-adaptive active charge balancing circuit with pulse-insertion based residual charge compensation and quantization for electrical stimulation applications , 2015, 2015 IEEE Asian Solid-State Circuits Conference (A-SSCC).

[17]  Rahul Sarpeshkar,et al.  A Low-Power Blocking-Capacitor-Free Charge-Balanced Electrode-Stimulator Chip With Less Than 6 nA DC Error for 1-mA Full-Scale Stimulation , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[18]  Daryl R Kipke,et al.  Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants , 2007, Journal of neural engineering.

[19]  Maysam Ghovanloo,et al.  A Power-Efficient Wireless System With Adaptive Supply Control for Deep Brain Stimulation , 2013, IEEE Journal of Solid-State Circuits.