Fast 3-D dark-field reflection-mode photoacoustic microscopy in vivo with a 30-MHz ultrasound linear array.

We present an in vivo dark-field reflection-mode photoacoustic microscopy system that performs cross-sectional (B-scan) imaging at 50 Hz with real-time beamforming and 3-D imaging consisting of 166 B-scan frames at 1 Hz with postbeamforming. To our knowledge, this speed is currently the fastest in photoacoustic imaging. A custom-designed light delivery system is integrated with a 30-MHz ultrasound linear array to realize dark-field reflection-mode imaging. Linear mechanical scanning of the array produces 3-D images. The system has axial, lateral, and elevational resolutions of 25, 70, and 200 microm, respectively, and can image 3 mm deep in scattering biological tissues. Volumetric images of subcutaneous vasculature in rats are demonstrated in vivo. Fast 3-D photoacoustic microscopy is anticipated to facilitate applications of photoacoustic imaging in biomedical studies that involve dynamics and clinical procedures that demand immediate diagnosis.

[1]  Lihong V. Wang,et al.  Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging , 2006, Nature Biotechnology.

[2]  Chang-Hong Hu,et al.  Development of a real-time, high-frequency ultrasound digital beamformer for high-frequency linear array transducers , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Martin Frenz,et al.  Combined ultrasound and optoacoustic system for real-time high-contrast vascular imaging in vivo , 2005, IEEE Transactions on Medical Imaging.

[4]  F. M. van den Engh,et al.  Initial results of in vivo non-invasive cancer imaging in the human breast using near-infrared photoacoustics. , 2007, Optics express.

[5]  Liang Song,et al.  Realtime photoacoustic microscopy in vivo with a 30-MHz ultrasound array transducer. , 2008, Optics express.

[6]  Lihong V. Wang,et al.  Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain , 2003, Nature Biotechnology.

[7]  Ketan Mehta,et al.  128-channel laser optoacoustic imaging system (LOIS-128) for breast cancer diagnostics , 2006, SPIE BiOS.

[8]  Da Xing,et al.  Fast full-view photoacoustic imaging by combined scanning with a linear transducer array. , 2007, Optics express.

[9]  Lihong V. Wang,et al.  Photoacoustic imaging of the microvasculature with a high-frequency ultrasound array transducer. , 2007, Journal of biomedical optics.

[10]  K.K. Shung,et al.  Development of a 35-MHz piezo-composite ultrasound array for medical imaging , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  L. Wang,et al.  Optimal beam size for light delivery to absorption-enhanced tumors buried in biological tissues and effect of multiple-beam delivery: a Monte Carlo study. , 1997, Applied optics.

[12]  Fred P. Seeber,et al.  OP-TEC national center for optics and photonics education and ANSI Z136.5 American National Standard for the safe use of lasers in educational institutions – How they will work together to improve laser safety in educational institutions , 2009 .

[13]  G.R. Lockwood,et al.  Modern implementation of a realtime 3D beamformer and scan converter system , 2005, IEEE Ultrasonics Symposium, 2005..

[14]  Benjamin A. Rockwell,et al.  Procedure for the computation of hazards from diffusely scattering surfaces under the Z136.1-2000 American National Standard for Safe Use of Lasers , 2007 .

[15]  John A Viator,et al.  Photoacoustic detection of metastatic melanoma cells in the human circulatory system. , 2006, Optics letters.

[16]  Da Xing,et al.  Noninvasive monitoring of traumatic brain injury and post-traumatic rehabilitation with laser-induced photoacoustic imaging , 2007 .

[17]  Jung-Taek Oh,et al.  Three-dimensional imaging of skin melanoma in vivo by dual-wavelength photoacoustic microscopy. , 2006, Journal of biomedical optics.

[18]  Lihong V. Wang,et al.  Biomedical Optics: Principles and Imaging , 2007 .