Three novel accurate pixel-driven projection methods for 2D CT and 3D EPR imaging.

OBJECTIVES This work aims to explore more accurate pixel-driven projection methods for iterative image reconstructions in order to reduce high-frequency artifacts in the generated projection image. METHODS Three new pixel-driven projection methods namely, small-pixel-large-detector (SPLD), linear interpolation based (LIB) and distance anterpolation based (DAB), were proposed and applied to reconstruct images. The performance of these methods was evaluated in both two-dimensional (2D) computed tomography (CT) images via the modified FORBILD phantom and three-dimensional (3D) electron paramagnetic resonance (EPR) images via the 6-spheres phantom. Specifically, two evaluations based on projection generation and image reconstruction were performed. For projection generation, evaluation was using a 2D disc phantom, the modified FORBILD phantom and the 6-spheres phantom. For image reconstruction, evaluations were performed using the FORBILD and 6-spheres phantom. During evaluation, 2 quantitative indices of root-mean-square-error (RMSE) and contrast-to-noise-ratio (CNR) were used. RESULTS Comparing to the use of ordinary pixel-driven projection method, RMSE of the SPLD based least-square algorithm was reduced from 0.0701 to 0.0384 and CNR was increased from 5.6 to 19.47 for 2D FORBILD phantom reconstruction. For 3D EPRI, RMSE of SPLD was also reduced from 0.0594 to 0.0498 and CNR was increased from 3.88 to 11.58. In addition, visual evaluation showed that images reconstructed in both 2D and 3D images suffered from high-frequency line-shape artifacts when using the ordinary pixel-driven projection method. However, using 3 new methods all suppressed the artifacts significantly and yielded more accurate reconstructions. CONCLUSIONS Three proposed pixel-driven projection methods achieved more accurate iterative image reconstruction results. These new and more accurate methods can also be easily extended to other imaging modalities. Among them, SPLD method should be recommended to 3D and four dimensional (4D) EPR imaging.

[1]  B. De Man,et al.  Distance-driven projection and backprojection , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[2]  G. L. Zeng,et al.  A RAY-DRIVEN BACKPRO JECTOR FOR BACKPRO JECTION FILTERING AND FILTERED BACKPRO JECTION ALGORITHMS , 1994 .

[3]  B. De Man,et al.  Distance-driven projection and backprojection in three dimensions. , 2004, Physics in medicine and biology.

[4]  Yuhua Qian,et al.  3D pulse EPR imaging from sparse-view projections via constrained, total variation minimization. , 2015, Journal of magnetic resonance.

[5]  Zhi-Pei Liang,et al.  Fast dynamic electron paramagnetic resonance (EPR) oxygen imaging using low-rank tensors. , 2016, Journal of magnetic resonance.

[6]  Matthias Zwicker,et al.  3 Ideal Resampling 3 . 1 Sampling and Aliasing , 2022 .

[7]  Jeffrey A. Fessler,et al.  3D Forward and Back-Projection for X-Ray CT Using Separable Footprints , 2010, IEEE Transactions on Medical Imaging.

[8]  Gengsheng L. Zeng,et al.  A Ray-driven Backprojector For Backprojection Filtering And Filtered Backprojection Algorithms , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.

[9]  Xiao Han,et al.  Artifact reduction in short-scan CBCT by use of optimization-based reconstruction , 2016, Physics in medicine and biology.

[10]  Hao Gao Fast parallel algorithms for the x-ray transform and its adjoint. , 2012, Medical physics.

[11]  Xiaochuan Pan,et al.  Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT , 2010, Physics in medicine and biology.

[12]  Emil Y. Sidky,et al.  Investigation of optimization-based reconstruction with an image-total-variation constraint in PET , 2015 .

[13]  P. Joseph An Improved Algorithm for Reprojecting Rays through Pixel Images , 1983, IEEE Transactions on Medical Imaging.

[14]  Gengsheng Lawrence Zeng,et al.  Unmatched projector/backprojector pairs in an iterative reconstruction algorithm , 2000, IEEE Transactions on Medical Imaging.

[15]  R L Siddon,et al.  Calculation of the radiological depth. , 1985, Medical physics.

[16]  Howard J Halpern,et al.  Spatially uniform sampling in 4-D EPR spectral-spatial imaging. , 2007, Journal of magnetic resonance.

[17]  Howard J Halpern,et al.  Maximally spaced projection sequencing in electron paramagnetic resonance imaging. , 2015, Concepts in magnetic resonance. Part B, Magnetic resonance engineering.

[18]  E. Sidky,et al.  Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle–Pock algorithm , 2011, Physics in medicine and biology.

[19]  Xiaochuan Pan,et al.  Optimization-based image reconstruction with artifact reduction in C-arm CBCT , 2016, Physics in medicine and biology.

[20]  T. M. Peters Algorithms for Fast Back- and Re-Projection in Computed Tomography , 1981 .

[21]  Howard J Halpern,et al.  Comparison of parabolic filtration methods for 3D filtered back projection in pulsed EPR imaging. , 2014, Journal of magnetic resonance.

[22]  Günter Lauritsch,et al.  Simulation tools for two-dimensional experiments in x-ray computed tomography using the FORBILD head phantom , 2012, Physics in medicine and biology.

[23]  Bin Yan,et al.  Fast parallel algorithm for three-dimensional distance-driven model in iterative computed tomography reconstruction , 2015 .

[24]  A. Akan,et al.  Iterative image reconstruction using non-local means with total variation from insufficient projection data. , 2016, Journal of X-ray science and technology.

[25]  Howard J Halpern,et al.  Simulation of 4D spectral-spatial EPR images. , 2007, Journal of magnetic resonance.