Subsecond and Submillimeter Resolution Positional Verification for Stereotactic Irradiation of Spinal Lesions.

PURPOSE Spine stereotactic body radiation therapy (SBRT) requires highly accurate positioning. We report our experience with markerless template matching and triangulation of kilovoltage images routinely acquired during spine SBRT, to determine spine position. METHODS AND MATERIALS Kilovoltage images, continuously acquired at 7, 11 or 15 frames/s during volumetric modulated spine SBRT of 18 patients, consisting of 93 fluoroscopy datasets (1 dataset/arc), were analyzed off-line. Four patients were immobilized in a head/neck mask, 14 had no immobilization. Two-dimensional (2D) templates were created for each gantry angle from planning computed tomography data and registered to prefiltered kilovoltage images to determine 2D shifts between actual and planned spine position. Registrations were considered valid if the normalized cross correlation score was ≥0.15. Multiple registrations were triangulated to determine 3D position. For each spine position dataset, average positional offset and standard deviation were calculated. To verify the accuracy and precision of the technique, mean positional offset and standard deviation for twenty stationary phantom datasets with different baseline shifts were measured. RESULTS For the phantom, average standard deviations were 0.18 mm for left-right (LR), 0.17 mm for superior-inferior (SI), and 0.23 mm for the anterior-posterior (AP) direction. Maximum difference in average detected and applied shift was 0.09 mm. For the 93 clinical datasets, the percentage of valid matched frames was, on average, 90.7% (range: 49.9-96.1%) per dataset. Average standard deviations for all datasets were 0.28, 0.19, and 0.28 mm for LR, SI, and AP, respectively. Spine position offsets were, on average, -0.05 (range: -1.58 to 2.18), -0.04 (range: -3.56 to 0.82), and -0.03 mm (range: -1.16 to 1.51), respectively. Average positional deviation was <1 mm in all directions in 92% of the arcs. CONCLUSIONS Template matching and triangulation using kilovoltage images acquired during irradiation allows spine position detection with submillimeter accuracy at subsecond intervals. Although the majority of patients were not immobilized, most vertebrae were stable at the sub-mm level during spine SBRT delivery.

[1]  Alexander Muacevic,et al.  Patient motion and targeting accuracy in robotic spinal radiosurgery: 260 single-fraction fiducial-free cases. , 2010, International journal of radiation oncology, biology, physics.

[2]  Hassan Mostafavi,et al.  Markerless tracking of small lung tumors for stereotactic radiotherapy. , 2015, Medical physics.

[3]  S Yoo,et al.  Analysis of image quality for real-time target tracking using simultaneous kV-MV imaging. , 2008, Medical physics.

[4]  Hassan Mostafavi,et al.  Intrafraction Tracking of Prostate Marker Motion using Sequential Stereo Imaging , 2010 .

[5]  H Mostafavi,et al.  WE-A-134-07: RapidTrack: A Versatile Tool for Template-Based Target Tracking During Radiotherapy. , 2013, Medical physics.

[6]  John T. Wei,et al.  Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. , 2006, International journal of radiation oncology, biology, physics.

[7]  Fang-Fang Yin,et al.  6D image guidance for spinal non-invasive stereotactic body radiation therapy: Comparison between ExacTrac X-ray 6D with kilo-voltage cone-beam CT. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  Thierry Gevaert,et al.  Treating patients with real-time tumor tracking using the Vero gimbaled linac system: implementation and first review. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  Fang-Fang Yin,et al.  Use of the BrainLAB ExacTrac X-Ray 6D system in image-guided radiotherapy. , 2008, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[10]  Paul J Keall,et al.  Real-time prostate trajectory estimation with a single imager in arc radiotherapy: a simulation study , 2009, Physics in medicine and biology.

[11]  Sasa Mutic,et al.  The ViewRay system: magnetic resonance-guided and controlled radiotherapy. , 2014, Seminars in radiation oncology.

[12]  David A Jaffray,et al.  Impact of immobilization on intrafraction motion for spine stereotactic body radiotherapy using cone beam computed tomography. , 2012, International journal of radiation oncology, biology, physics.

[13]  Lei Xing,et al.  An end-to-end examination of geometric accuracy of IGRT using a new digital accelerator equipped with onboard imaging system , 2012, Physics in medicine and biology.

[14]  Paul J Keall,et al.  First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking. , 2009, International journal of radiation oncology, biology, physics.

[15]  A. Muacevic,et al.  Advances in fiducial‐free image‐guidance for spinal radiosurgery with CyberKnife – a phantom study , 2010, Journal of applied clinical medical physics.

[16]  S. Senan,et al.  Dosimetric impact of intrafraction motion during RapidArc stereotactic vertebral radiation therapy using flattened and flattening filter-free beams. , 2013, International journal of radiation oncology, biology, physics.

[17]  Shinichi Shimizu,et al.  Optimization of fluoroscopy parameters using pattern matching prediction in the real-time tumor-tracking radiotherapy system. , 2011, Physics in medicine and biology.

[18]  Lijun Ma,et al.  Spine stereotactic body radiotherapy utilizing cone-beam CT image-guidance with a robotic couch: intrafraction motion analysis accounting for all six degrees of freedom. , 2012, International journal of radiation oncology, biology, physics.

[19]  Alexander Sloutsky,et al.  WE‐D‐204B‐08: Tracking 3D Trajectory of Internal Markers Using Radiographic Sequential Stereo Imaging: Estimation of Breathing Motion , 2010 .

[20]  T. Solberg,et al.  Localization accuracy and immobilization effectiveness of a stereotactic body frame for a variety of treatment sites. , 2013, International journal of radiation oncology, biology, physics.

[21]  H. Mostafavi,et al.  Detection and localization of radiotherapy targets by template matching , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  P J Keall,et al.  Determining appropriate imaging parameters for kilovoltage intrafraction monitoring: an experimental phantom study , 2015, Physics in medicine and biology.

[23]  Quynh-Thu Le,et al.  Patterns of patient movement during frameless image-guided radiosurgery. , 2003, International journal of radiation oncology, biology, physics.

[24]  B. Slotman,et al.  Frameless high dose rate stereotactic lung radiotherapy: intrafraction tumor position and delivery time. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  J. Kuijer,et al.  Imaging for stereotactic spine radiotherapy: clinical considerations. , 2011, International journal of radiation oncology, biology, physics.

[26]  Hassan Mostafavi,et al.  Digital tomosynthesis for verifying spine position during radiotherapy: a phantom study , 2013, Physics in medicine and biology.

[27]  Max Dahele,et al.  Sub-millimeter spine position monitoring for stereotactic body radiotherapy using offline digital tomosynthesis. , 2015, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[28]  D. Larson,et al.  Stereotactic body radiosurgery for spinal metastases: a critical review. , 2008, International journal of radiation oncology, biology, physics.

[29]  Todsaporn Fuangrod,et al.  First Experience With Real-Time EPID-Based Delivery Verification During IMRT and VMAT Sessions. , 2015, International journal of radiation oncology, biology, physics.

[30]  Max Dahele,et al.  An analysis of patient positioning during stereotactic lung radiotherapy performed without rigid external immobilization. , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[31]  J. Rock,et al.  Evaluation of residual patient position variation for spinal radiosurgery using the Novalis image guided system. , 2008, Medical physics.

[32]  P. Munro,et al.  Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58. , 2001, Medical physics.

[33]  Wilhelm Burger,et al.  Principles of Digital Image Processing - Core Algorithms , 2009, Undergraduate Topics in Computer Science.