Ventilation strategies and indoor particulate matter in a classroom.

Particle mass and number concentrations were measured in a mechanically ventilated classroom as part of a study of ventilation strategies for energy conservation. The ventilation system was operated either continuously, intermittently, or shut down during nights while it was on during workdays. It appears that the nighttime ventilation scheme is not important for indoor particle concentrations the following day if fans are operated to give five air exchanges in advance of the workday. The highest concentrations of PM10 were found during and after workdays and were due to human activity in the classroom. The average workday PM10 concentration was 14 μg/m(3) , well below the WHO guideline values. The number concentration of particles with diameter <0.750 μm was typically between 0.5 × 10(3) and 3.5 × 10(3)  particle/cm(3) . These concentrations were largely independent of the occupants. Transient formation of small particles was observed when ventilation was shut down. Then remaining ozone reacted with terpenes emitted by indoor sources and gave up to 8 × 10(3)  particle/cm(3) before formation stopped due to lack of ozone. The intermittent ventilation regime was found least favorable for the indoor air quality in the classroom.

[1]  S. Langer,et al.  Ozone removal by occupants in a classroom , 2013 .

[2]  U. Haverinen-Shaughnessy,et al.  Association between substandard classroom ventilation rates and students' academic achievement. , 2011, Indoor air.

[3]  Martin Braniš,et al.  Exposure of children to airborne particulate matter of different size fractions during indoor physical education at school , 2009 .

[4]  K. Becker,et al.  Studies on the formation of H2O2 in the ozonolysis of alkenes , 1993 .

[5]  Tareq Hussein,et al.  Activity pattern of a selected group of school occupants and their family members in Helsinki-Finland. , 2012, The Science of the total environment.

[6]  Scott Weichenthal,et al.  Characterizing and predicting ultrafine particle counts in Canadian classrooms during the winter months: model development and evaluation. , 2008, Environmental research.

[7]  L. Morawska,et al.  Ultrafine particles in indoor air of a school: possible role of secondary organic aerosols. , 2009, Environmental science & technology.

[8]  Martin Branis,et al.  The effect of outdoor air and indoor human activity on mass concentrations of PM(10), PM(2.5), and PM(1) in a classroom. , 2005, Environmental research.

[9]  U Haverinen-Shaughnessy,et al.  A preliminary study on the association between ventilation rates in classrooms and student performance. , 2006, Indoor air.

[10]  Lidia Morawska,et al.  Spatial variation of particle number concentration in school microscale environments and its impact on exposure assessment. , 2013, Environmental science & technology.

[11]  E. R. Jayaratne,et al.  Indoor aerosols: from personal exposure to risk assessment. , 2013, Indoor air.

[12]  M. Kulmala,et al.  Formation and growth of indoor air aerosol particles as a result of D-limonene oxidation , 2006 .

[13]  W W Nazaroff,et al.  Ultrafine particle concentrations and exposures in six elementary school classrooms in northern California. , 2011, Indoor air.

[14]  Bernhard Liebl,et al.  Particulate matter in the indoor air of classrooms—exploratory results from Munich and surrounding area , 2007 .

[15]  Lidia Morawska,et al.  Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom , 2008 .

[16]  Margarita Evtyugina,et al.  Children exposure to atmospheric particles in indoor of Lisbon primary schools , 2011 .

[17]  Alexandra Schneider,et al.  Health effects of particulate air pollution: A review of epidemiological evidence , 2011, Inhalation toxicology.

[18]  P J Lioy,et al.  Ozone and limonene in indoor air: a source of submicron particle exposure. , 2000, Environmental health perspectives.

[19]  Sarka Langer,et al.  Chemistry and indoor air quality in a multi-storey wooden passive (low energy) building: Formation of peroxyacetyl nitrate , 2014 .

[20]  Bert Brunekreef,et al.  Air Pollution from Truck Traffic and Lung Function in Children Living near Motorways , 1997, Epidemiology.

[21]  S. Batterman,et al.  Determinants of personal, indoor and outdoor VOC concentrations: an analysis of the RIOPA data. , 2013, Environmental research.

[22]  G. Heath,et al.  Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature. , 2005, Indoor air.

[23]  Sarka Langer,et al.  Ultrafine particles produced by ozone/limonene reactions in indoor air under low/closed ventilation conditions , 2008 .

[24]  Peder Wolkoff,et al.  The effect of nitrogen dioxide on particle formation during ozonolysis of two abundant monoterpenes indoors , 2006 .

[25]  Luca Stabile,et al.  Dimensional and chemical characterization of airborne particles in schools: Respiratory effects in children , 2013 .

[26]  F. Sennhauser,et al.  Decline of Ambient Air Pollution Levels and Improved Respiratory Health in Swiss Children , 2005, Environmental health perspectives.

[27]  Charles J. Weschler,et al.  Indoor ozone/terpene reactions as a source of indoor particles , 1999 .

[28]  William W Nazaroff,et al.  Indoor secondary pollutants from household product emissions in the presence of ozone: A bench-scale chamber study. , 2006, Environmental science & technology.